4 research outputs found

    Simple and Sensitive Analysis of Clenbuterol in Urine Matrices by UHPLC-MS/MS Method with Online-SPE Sample Preparation

    No full text
    Clenbuterol is one of the most misused anabolic agents in professional sports. Therefore, the monitoring of clenbuterol in body fluids such as human urine is related to the development of rapid, selective and sensitive analytical methods that produce reliable results. In this work, these requirements were met by a two-dimensional separation method based on online solid-phase extraction coupled with ultra-high performance liquid chromatography–tandem mass spectrometry (SPE–UHPLC–MS/MS). The developed method provides favorable performance parameters, and it is characterized by minimum manual steps (only dilution and the addition of an internal standard) in the sample preparation. A limit of quantification (LOQ) of 0.1 ng/mL, excellent linearity (0.9999), remarkable precision (1.26% to 8.99%) and high accuracy (93.1% to 98.7%) were achieved. From a practical point of view, the analytical performance of the validated SPE–UHPLC–MS/MS method was demonstrated on blinded spiked urine samples from ten healthy volunteers. The estimated concentrations of clenbuterol were in accordance with their corresponding nominal values, as supported by the precision and accuracy data (relative standard deviation ≤5.4%, relative error ≤11%). The fulfillment of the World Anti-Doping Agency’s screening and confirmation criteria indicates that the proposed method is suitable for implementation in routine use in toxicologic and antidoping laboratories. Due to its high orthogonality and separation efficiency, the SPE–UHPLC–MS/MS method should also be easily adapted to the separation of structurally related compounds (such as clenbuterol metabolites). Thus, future antidoping applications could also include monitoring of clenbuterol metabolites, providing a longer detection widow

    GM3 Ganglioside Linked to Neurofibrillary Pathology in a Transgenic Rat Model for Tauopathy

    No full text
    Glycosphingolipids (GSLs) are amphipathic lipids composed of a sphingoid base and a fatty acyl attached to a saccharide moiety. GSLs play an important role in signal transduction, directing proteins within the membrane, cell recognition, and modulation of cell adhesion. Gangliosides and sulfatides belong to a group of acidic GSLs, and numerous studies report their involvement in neurodevelopment, aging, and neurodegeneration. In this study, we used an approach based on hydrophilic interaction liquid chromatography (HILIC) coupled to high-resolution tandem mass spectrometry (HRMS/MS) to characterize the glycosphingolipid profile in rat brain tissue. Then, we screened characterized lipids aiming to identify changes in glycosphingolipid profiles in the normal aging process and tau pathology. Thorough screening of acidic glycosphingolipids in rat brain tissue revealed 117 ganglioside and 36 sulfatide species. Moreover, we found two ganglioside subclasses that were not previously characterized—GT1b-Ac2 and GQ1b-Ac2. The semi-targeted screening revealed significant changes in the levels of sulfatides and GM1a gangliosides during the aging process. In the transgenic SHR24 rat model for tauopathies, we found elevated levels of GM3 gangliosides which may indicate a higher rate of apoptotic processes

    Fast and Sensitive Screening of Oxandrolone and Its Major Metabolite 17-Epi-Oxandrolone in Human Urine by UHPLC—MS/MS with On-Line SPE Sample Pretreatment

    No full text
    Oxandrolone, a synthetic testosterone analog, is used for the treatment of several diseases associated with weight loss. Unfortunately, oxandrolone is abused by many athletes and bodybuilders due to its strong anabolic effect. We have developed and validated a highly sensitive and rapid on-line SPE-UHPLC-MS/MS method for the determination of oxandrolone and simultaneous identification of its major metabolite 17-epi-oxandrolone in urine matrices. Enrichment of the analytes via an integrated solid-phase extraction was achieved using an Acquity UPLC BEH C18 Column. Subsequently, the chromatographic separation of the on-line preconcentrated sample fraction was achieved using an Acquity HSS T3 C18 Column. For the structural identification of these analytes, a high-resolution mass spectrometer Synapt-G2Si coupled to the Acquity M-class nano-LC system with ionKey source was used. A highly sensitive determination of oxandrolone was achieved using a tandem quadrupole mass spectrometer XEVO TQD. The method was successfully validated in the linear range of oxandrolone from 81.63 pg·mL−1 (limit of quantification, LOQ) to 5000 pg·mL−1 in the human urine matrix. It was applied to the analysis of real urine samples obtained from a healthy volunteer after the oral administration of one dose (10 mg) of oxandrolone. Concentration vs. time dependence was tested in the time interval of 4 h–12 days (after oral administration) to demonstrate the ability of the method to detect the renal elimination of oxandrolone from the human body. Favorable performance parameters along with successful application indicate the usefulness of the proposed method for its routine use in antidoping control labs
    corecore