9 research outputs found

    Diagnostic accuracy of dynamic CZT-SPECT in coronary artery disease. A systematic review and meta-analysis

    Get PDF
    Background: With the appearance of cadmium-zinc-telluride (CZT) cameras, dynamic myocardial perfusion imaging (MPI) has been introduced, but comparable data to other MPI modalities, such as quantitative coronary angiography (CAG) with fractional flow reserve (FFR) and positron emission tomography (PET), are lacking. This study aimed to evaluate the diagnostic accuracy of dynamic CZT single-photon emission tomography (SPECT) in coronary artery disease compared to quantitative CAG, FFR, and PET as reference. Materials and Methods: Different databases were screened for eligible citations performing dynamic CZT-SPECT against CAG, FFR, or PET. PubMed, OvidSP (Medline), Web of Science, the Cochrane Library, and EMBASE were searched on the 5th of July 2020. Studies had to meet the following pre-established inclusion criteria: randomized controlled trials, retrospective trails or observational studies relevant for the diagnosis of coronary artery disease, and performing CZT-SPECT and within half a year the methodological references. Studies which considered coronary stenosis between 50% and 70% as significant based only on CAG were excluded. Data extracted were sensitivity, specificity, likelihood ratios, and diagnostic odds ratios. Quality was assessed with QUADAS-2 and statistical analysis was performed using a bivariate model. Results: Based on our criteria, a total of 9 studies containing 421 patients were included. For the assessment of CZT-SPECT, the diagnostic value pooled analysis with a bivariate model was calculated and yielded a sensitivity of 0.79 (% CI 0.73 to 0.85) and a specificity of 0.85 (95% CI 0.74 to 0.92). Diagnostic odds ratio (DOR) was 17.82 (95% CI 8.80 to 36.08, P < 0.001). Positive likelihood ratio (PLR) and negative likelihood ratio (NLR) were 3.86 (95% CI 2.76 to 5.38, P < 0.001) and 0.21 (95% CI 0.13 to 0.33, P < 0.001), respectively. Conclusion: Based on the results of the current systematic review and meta-analysis, dynamic CZT-SPECT MPI demonstrated a good sensitivity and specificity to diagnose CAD as compared to the gold standards. However, due to the heterogeneity of the methodologies between the CZT-SPECT MPI studies and the relatively small number of included studies, it warrants further well-defined study protocols

    Added Value of Transluminal Attenuation Gradient to Qualitative CCTA Ischemia Detection as Determined by N-13-ammonia PET Quantitative Myocardial Perfusion

    Get PDF
    Transluminal attenuation gradient (TAG) represents the slope of intraluminal contrast that decreases along a coronary vessel during coronary computed tomography angiography (CCTA). The aim of this study was to determine the added value of TAG to qualitative CCTA assessment of significant stenosis (>50%) detecting ischemia as determined by stress myocardial blood flow (MBF) or myocardial flow reserve (MFR) measured by positron emission tomography (PET). Individual contributions of TAG, qualitative assessment and the impact of calcium score were also investigated. METHODS: We studied 38 consecutive patients that were referred due to suspected or known coronary artery disease (CAD). All patients underwent a two-phase hybrid 13N-ammonia PET/CT and CCTA. RESULTS: TAG and presence of qualitatively assessed significant stenosis, but not calcium score, were associated with stress myocardial blood flow (MBF) and myocardial flow reserve (MFR). The area under the curves (AUC) of the linear predictor model including qualitative assessment and TAG was superior to the AUC of separate qualitative assessment or TAG for the detection of ischemia according to stress MBF (AUCs were: 88% vs. 79% and 77%; p = 0.01 and p = 0.01, respectively). CONCLUSIONS: TAG combined with qualitative CCTA assessment improved ischemia detection

    Radiation dose optimization for photon-counting CT coronary artery calcium scoring for different patient sizes:a dynamic phantom study

    Get PDF
    PURPOSE: To systematically assess the radiation dose reduction potential of coronary artery calcium (CAC) assessments with photon-counting computed tomography (PCCT) by changing the tube potential for different patient sizes with a dynamic phantom.METHODS: A hollow artery, containing three calcifications of different densities, was translated at velocities corresponding to 0, &lt; 60, 60-75, and &gt; 75 beats per minute within an anthropomorphic phantom. Extension rings were used to simulate average- and large -sized patients. PCCT scans were made with the reference clinical protocol (tube potential of 120 kilovolt (kV)), and with 70, 90, Sn100, Sn140, and 140 kV at identical image quality levels. All acquisitions were reconstructed at a virtual monoenergetic energy level of 70 keV. For each calcification, Agatston scores and contrast-to-noise ratios (CNR) were determined, and compared to the reference with Wilcoxon signed-rank tests, with p &lt; 0.05 indicating significant differences.RESULTS: A decrease in radiation dose (22%) was achieved at Sn100 kV for the average-sized phantom. For the large phantom, Sn100 and Sn140 kV resulted in a decrease in radiation doses of 19% and 3%, respectively. Irrespective of CAC density, Sn100 and 140 kVp did not result in significantly different CNR. Only at Sn100 kV were there no significant differences in Agatston scores for all CAC densities, heart rates, and phantom sizes.CONCLUSION: PCCT at tube voltage of 100 kV with added tin filtration and reconstructed at 70 keV enables a ≥ 19% dose reduction compared to 120 kV, independent of phantom size, CAC density, and heart rate.KEY POINTS: • Photon-counting CT allows for reduced radiation dose acquisitions (up to 19%) for coronary calcium assessment by reducing tube voltage while reconstructing at a normal monoE level of 70 keV. • Tube voltage reduction is possible for medium and large patient sizes, without affecting the Agatston score outcome.</p

    Coronary plaque redistribution after stent implantation is determined by lipid composition: A NIRS-IVUS analysis

    Get PDF
    Background: The composition of plaque impacts the results of stenting. The following study evaluated plaque redistribution related to stent implantation using combined near-infrared spectroscopy and intravascular ultrasound (NIRS-IVUS) imaging. Methods: The present study included 49 patients (mean age 66 ± 11 years, 75% males) presenting with non-ST elevation myocardial infarction (8%), unstable angina (49%) and stable coronary artery disease (43%). The following parameters were analyzed: mean plaque volume (MPV, mm3), plaque burden (PB, %), remodeling index (RI), and maximal lipid core burden index in a 4 mm segment (maxLCBI4mm). High-lipid burden lesions (HLB) were defined as by maxLCBI4mm &gt; 265 with positive RI. Otherwise plaques were defined as low-lipid burden lesions (LLB). Measurements were done in the target lesion and in 4 mm edges of the stent before and after stent implantation. Results: MPV and maxLCBI4mm decreased in both HLB (MPV 144.70 [80.47, 274.25] vs. 97.60 [56.82, 223.45]; maxLCBI4mm: 564.11 ± 166.82 vs. 258.11 ± 234.24, p = 0.004) and LLB (MPV: 124.50 [68.00, 186.20] vs. 101.10 [67.87, 165.95]; maxLCBI4mm: 339.07 ± 268.22 vs. 124.60 ± 160.96, p &lt; 0.001), but MPV decrease was greater in HLB (28.00 [22.60, 57.10] vs. 13.50 [1.50, 28.84], p = 0.019). Only at the proximal stent edge of LLB, maxLCBI4mm decreased (34 [0, 207] vs. 0 [0, 45], p = 0.049) and plaque burden increased (45.48 [40.34, 51.55] vs. 51.75 [47.48, 55.76], p = 0.030). Conclusions: NIRS-IVUS defined HLB characterized more significant decreases in plaque volume by stenting. Plaque redistribution to the proximal edge of the implanted stent occurred only in LLB

    Optimized detection, visualization, and quantification of the coronary artery plaque – which pathway?

    Get PDF
    In this thesis detection, visualisation, and quantification of coronary artery plaque using different imaging methods was investigated. First, preclinical studies were performed to assess the effectiveness of improving coronary artery calcium scoring using both calcium scoring CT (CSCT) and coronary CT angiography (CCTA). Second, the ability of low-dose CT (LDCT) to detect coronary artery calcium was evaluated in conjunction with myocardial perfusion PET. Furthermore, the improvement in major adverse cardiac events prediction based on coronary artery calcium (CAC) derived from LDCT scans was examined. Third, coronary artery plaque analysis was performed in patients from the highest cardiovascular risk group. Fourth, a prospective study was proposed in which both invasive and non-invasive methods will be applied to differentiate between ischemia caused by aortic stenosis and coronary artery stenosis

    Optimized detection, visualization, and quantification of the coronary artery plaque – which pathway?

    Get PDF
    In this thesis detection, visualisation, and quantification of coronary artery plaque using different imaging methods was investigated. First, preclinical studies were performed to assess the effectiveness of improving coronary artery calcium scoring using both calcium scoring CT (CSCT) and coronary CT angiography (CCTA). Second, the ability of low-dose CT (LDCT) to detect coronary artery calcium was evaluated in conjunction with myocardial perfusion PET. Furthermore, the improvement in major adverse cardiac events prediction based on coronary artery calcium (CAC) derived from LDCT scans was examined. Third, coronary artery plaque analysis was performed in patients from the highest cardiovascular risk group. Fourth, a prospective study was proposed in which both invasive and non-invasive methods will be applied to differentiate between ischemia caused by aortic stenosis and coronary artery stenosis

    Vendor Independent Coronary Calcium Scoring Improves Individual Risk Assessment:The Multi-Ethnic Study of Atherosclerosis (MESA)

    Get PDF
    BACKGROUND: Substantial variation in Agatston scores (AS) acquired with different computed tomography (CT) scanners may influence patient risk classification.OBJECTIVES: This study sought to develop a calibration tool for state-of-the-art CT systems resulting in vendor-neutral AS (vnAS), and to assess the impact of vnAS on coronary heart disease (CHD) event prediction.METHODS: The vnAS calibration tool was derived by imaging 2 anthropomorphic calcium containing phantoms on 7 different CT and 1 electron beam tomography system, which was used as the reference system. The effect of vnAS on CHD event prediction was analyzed with data from 3,181 participants from MESA (Multi-Ethnic Study on Atherosclerosis). Chi-square analysis was used to compare CHD event rates between low (vnAS &lt;100) and high calcium groups (vnAS ≥100). Multivariable Cox proportional hazard regression models were used to assess the incremental value of vnAS.RESULTS: For all CT systems, a strong correlation with electron beam tomography-AS was found (R 2 &gt;0.932). Of the MESA participants originally in the low calcium group (n = 781), 85 (11%) participants were reclassified to a higher risk category based on the recalculated vnAS. For reclassified participants, the CHD event rate of 15% was significantly higher compared with participants in the low calcium group (7%; P = 0.008) with a CHD HR of 3.39 (95% CI: 1.82-6.35; P = 0.001). CONCLUSIONS: The authors developed a calibration tool that enables calculation of a vnAS. MESA participants who were reclassified to a higher calcium category by means of the vnAS experienced more CHD events, indicating improved risk categorization.</p

    Performance of visual, manual, and automatic coronary calcium scoring of cardiac 13N-ammonia PET/low dose CT

    Get PDF
    Background: Coronary artery calcium is a well-known predictor of major adverse cardiac events and is usually scored manually from dedicated, ECG-triggered calcium scoring CT (CSCT) scans. In clinical practice, a myocardial perfusion PET scan is accompanied by a non-ECG triggered low dose CT (LDCT) scan. In this study, we investigated the accuracy of patients’ cardiovascular risk categorisation based on manual, visual, and automatic AI calcium scoring using the LDCT scan. Methods: We retrospectively enrolled 213 patients. Each patient received a 13N-ammonia PET scan, an LDCT scan, and a CSCT scan as the gold standard. All LDCT and CSCT scans were scored manually, visually, and automatically. For the manual scoring, we used vendor recommended software (Syngo.via, Siemens). For visual scoring a 6-points risk scale was used (0; 1-10; 11-100; 101-400; 401-100; > 1 000 Agatston score). The automatic scoring was performed with deep learning software (Syngo.via, Siemens). All manual and automatic Agatston scores were converted to the 6-point risk scale. Manual CSCT scoring was used as a reference. Results: The agreement of manual and automatic LDCT scoring with the reference was low [weighted kappa 0.59 (95% CI 0.53-0.65); 0.50 (95% CI 0.44-0.56), respectively], but the agreement of visual LDCT scoring was strong [0.82 (95% CI 0.77-0.86)]. Conclusions: Compared with the gold standard manual CSCT scoring, visual LDCT scoring outperformed manual LDCT and automatic LDCT scoring
    corecore