19 research outputs found

    Geomagnetically induced current model validation from New Zealand's South Island

    Get PDF
    Geomagnetically induced currents (GICs) during a space weather event have previously caused transformer damage in New Zealand. During the 2015 St. Patrick's Day Storm, Transpower NZ Ltd has reliable GIC measurements at 23 different transformers across New Zealand's South Island. These observed GICs show large variability, spatially and within a substation. We compare these GICs with those calculated from a modeled geolectric field using a network model of the transmission network with industry‐provided line, earthing, and transformer resistances. We calculate the modeled geoelectric field from the spectra of magnetic field variations interpolated from measurements during this storm and ground conductance using a thin‐sheet model. Modeled and observed GIC spectra are similar, and coherence exceeds the 95% confidence threshold, for most valid frequencies at 18 of the 23 transformers. Sensitivity analysis shows that modeled GICs are most sensitive to variation in magnetic field input, followed by the variation in land conductivity. The assumption that transmission lines follow straight lines or getting the network resistances exactly right is less significant. Comparing modeled and measured GIC time series highlights that this modeling approach is useful for reconstructing the timing, duration, and relative magnitude of GIC peaks during sudden commencement and substorms. However, the model significantly underestimates the magnitude of these peaks, even for a transformer with good spectral match. This is because of the limited range of frequencies for which the thin‐sheet model is valid and severely limits the usefulness of this modeling approach for accurate prediction of peak GICs

    Geomagnetically induced current model in New Zealand across multiple disturbances: Validation and extension to non‐monitored transformers

    Get PDF
    Geomagnetically induced currents (GICs) produced during geomagnetic disturbances pose a risk to the safe operation of electrical power networks. One route to determine the hazard of large and extreme geomagnetic disturbances to national electrical networks is a validated model to predict GIC across the entire network. In this study we improve upon an earlier model for New Zealand, expanding the approach to cover transformers nationwide by making use of multiple storms to develop national scaling factors. We exploit GIC observations which have been made and archived by Transpower New Zealand Ltd, the national grid operator. For some transformers the GIC observations span nearly 2 decades, while for others only a few years. GICs can vary wildly between transformers, particularly due to differences in the electrical network characteristics , transformer properties, and ground conductivity. Modeling these individual transformers is required if an accurate representation of the GIC distribution throughout the network is to be produced. Here we model the GIC during 25 disturbed periods, ranging from large geomagnetic storms to weakly active periods. We adopt the approach of scaling model output using observed GIC power spectra, finding that it improves the correlations between the maximum model and observed GIC by between 10-40% depending on the transformer. The modeled GIC at the 73 transformers which have measured GIC are analyzed to create local and national scaling curves. These are used to allow modeling for transformers without in-situ GIC. We present approaches to utilise this technique for future storms, including non-monitored transformers

    Modeling geoelectric fields and geomagnetically induced currents around New Zealand to explore GIC in the South Island's electrical transmission network

    Get PDF
    Transformers in New Zealand's South Island electrical transmission network have been impacted by geomagnetically induced currents (GIC) during geomagnetic storms. We explore the impact of GIC on this network by developing a thin-sheet conductance (TSC) model for the region, a geoelectric field model, and a GIC network model. (The TSC is composed of a thin-sheet conductance map with underlying layered resistivity structure.) Using modeling approaches that have been successfully used in the United Kingdom and Ireland, we applied a thin-sheet model to calculate the electric field as a function of magnetic field and ground conductance. We developed a TSC model based on magnetotelluric surveys, geology, and bathymetry, modified to account for offshore sediments. Using this representation, the thin sheet model gave good agreement with measured impedance vectors. Driven by a spatially uniform magnetic field variation, the thin-sheet model results in electric fields dominated by the ocean-land boundary with effects due to the deep ocean and steep terrain. There is a strong tendency for the electric field to align northwest-southeast, irrespective of the direction of the magnetic field. Applying this electric field to a GIC network model, we show that modeled GIC are dominated by northwest-southeast transmission lines rather than east-west lines usually assumed to dominate

    Transformer-level modeling of geomagnetically induced currents in New Zealand's South Island

    Get PDF
    During space weather events, geomagnetically induced currents (GICs) can be induced in high-voltage transmission networks, damaging individual transformers within substations. A common approach to modeling a transmission network has been to assume that every substation can be represented by a single resistance to Earth. We have extended that model by building a transformer-level network representation of New Zealand’s South Island transmission network. We represent every transformer winding at each earthed substation in the network by its known direct current resistance. Using this network representation significantly changes the GIC hazard assessment, compared to assessments based on the earlier assumption. Further, we have calculated the GIC flowing through a single phase of every individual transformer winding in the network. These transformer-level GIC calculations show variation in GICs between transformers within a substation due to transformer characteristics and connections. The transformer-level GIC calculations alter the hazard assessment by up to an order of magnitude in some places. In most cases the calculated GIC variations match measured variations in GIC flowing through the same transformers. This comparison with an extensive set of observations demonstrates the importance of transformer-level GIC calculations in models used for hazard assessment

    Geomagnetically Induced Current Mitigation in New Zealand: Operational Mitigation Method Development With Industry Input

    Get PDF
    Reducing the impact of Geomagnetically induced currents (GICs) on electrical power networks is an essential step to protect network assets and maintain reliable power transmission during and after storm events. In this study, multiple mitigation strategies are tested during worst-case extreme storm scenarios in order to investigate their effectiveness for the New Zealand transmission network. By working directly with our industry partners, Transpower New Zealand Ltd, a mitigation strategy in the form of targeted line disconnections has been developed. This mitigation strategy proved more effective than previous strategies at reducing GIC magnitudes and durations at transformers at most risk to GIC while still maintaining the continuous supply of power throughout New Zealand. Under this mitigation plan, the average 60-min mean GIC decreased for 27 of the top 30 at-risk transformers, and the total network GIC was reduced by 16%. This updated mitigation has been adopted as an operational procedure in the New Zealand national control room to manage GIC. In addition, simulations show that the installation of 14 capacitor blocking devices at specific transformers reduces the total GIC sum in the network by an additional 16%. As a result of this study Transpower is considering further mitigation in the form of capacitor blockers. We strongly recommend collaborating with the relevant power network providers to develop effective mitigation strategies that reduce GIC and have a minimal impact on power distribution
    corecore