43 research outputs found

    Análise energética de condicionadores convencionais e inverter em habitações não adaptadas ao clima

    Get PDF
    The energy consumption of air conditioners in buildings in hot and humid regions is relevant, especially in those not adapted to the climate. This study aimed to compare the consumption and performance of split inverter and conventional split air conditioners. The analysis was performed through thermo-energetic simulations, using the ©Energy Plus program and the application, ©Open Studio. Operating conditions and technical characteristics of the systems were based on the NBR 16555 standard. A real social interest housing was considered as a reference model, based on parameters of use and occupation of the Technical Quality Regulation for the level of energy efficiency (RTQ-R) . The virtual model of the building and the operational behavior of the air conditioning systems were obtained through performance curves. It was concluded that the use of inverter-type conditioners in homes not adapted to the climate, object of this research, proved to be efficient when compared to conventional conditioners. It is assumed that the replacement of conventional split equipment by split inverter can reduce electricity consumption by up to 41% per year, considering current energy efficiency levels. Inverter-type conditioners manage to minimize the consumption of electricity, which would hypothetically make the use of more efficient equipment accessible to less favored classes.El consumo energético de los acondicionadores de aire en edificios en regiones cálidas y húmedas es relevante, especialmente en aquellos no adaptados al clima. Este estudio tuvo como objetivo comparar el consumo y el rendimiento de los aires acondicionados split inverter y split convencionales. El análisis se realizó a través de simulaciones termoenergéticas, utilizando el programa ©Energy Plus y la aplicación ©Open Studio. Las condiciones de operación y las características técnicas de los sistemas se basaron en la norma NBR 16555. Se consideró como modelo de referencia una vivienda de interés social real, con base en los parámetros de uso y ocupación del Reglamento Técnico de Calidad para el nivel de eficiencia energética (RTQ-R ) . El modelo virtual del edificio y el comportamiento operativo de los sistemas de aire acondicionado se obtuvieron a través de curvas de rendimiento. Se concluyó que el uso de acondicionadores tipo inverter en viviendas no adaptadas al clima, objeto de esta investigación, demostró ser eficiente en comparación con los acondicionadores convencionales. Se supone que la sustitución de equipos split convencionales por split inverter puede reducir el consumo eléctrico hasta en un 41% anual, considerando los niveles de eficiencia energética actuales. Los acondicionadores de tipo inverter logran minimizar el consumo de energía eléctrica, lo que hipotéticamente haría accesible el uso de equipos más eficientes a las clases menos favorecidas.O consumo de energia de condicionadores de ar em edificações em regiões quentes e úmido se mostra relevante, em especial, naquelas não adaptadas ao clima. O presente trabalho teve por objetivo comparar o consumo e o rendimento de condicionadores de ar do tipo Split inverter e Split convencional. A análise foi realizada por meio de Simulações termo energéticas, utilizando o programa ©Energy Plus e o aplicativo, ©Open Studio. Condições operacionais e características técnicas dos sistemas foram embasadas na norma NBR 16555. Considerou-se uma Habitação de interesse social real como modelo referência, fundamentando em parâmetros de uso e ocupação do Regulamento técnico da qualidade para o nível de eficiência energética (RTQ-R). Obteve-se o modelo virtual da edificação e o comportamento operacional dos sistemas condicionadores de ar por meio de curvas de desempenho. Concluiu-se que, o uso de condicionadores do tipo inverter nas habitações não adaptadas ao clima, objeto da presente pesquisa se mostrou eficiente quando comparado a condicionadores convencionais. Assume-se que a substituição do equipamento split convencional por split inverter pode reduzir o consumo de eletricidade em até 41% ao ano, considerando os níveis de eficiência energéticas vigentes. Os condicionadores do tipo inverter conseguem minimizar o consumo de energia elétrica, o que tornaria acessível hipoteticamente a utilização de equipamentos mais eficientes as classes menos favorecidas

    Análise energética de condicionadores convencionais e inverter em habitações não adaptadas ao clima

    Get PDF
    O consumo de energia de condicionadores de ar em edificações em regiões quentes e úmido se mostra relevante, em especial, naquelas não adaptadas ao clima. O presente trabalho teve por objetivo comparar o consumo e o rendimento de condicionadores de ar do tipo Split inverter e Split convencional. A análise foi realizada por meio de Simulações termo energéticas, utilizando o programa ©Energy Plus e o aplicativo, ©Open Studio. Condições operacionais e características técnicas dos sistemas foram embasadas na norma NBR 16555. Considerou-se uma Habitação de interesse social real como modelo referência, fundamentando em parâmetros de uso e ocupação do Regulamento técnico da qualidade para o nível de eficiência energética (RTQ-R). Obteve-se o modelo virtual da edificação e o comportamento operacional dos sistemas condicionadores de ar por meio de curvas de desempenho. Concluiu-se que, o uso de condicionadores do tipo inverter nas habitações não adaptadas ao clima, objeto da presente pesquisa se mostrou eficiente quando comparado a condicionadores convencionais. Assume-se que a substituição do equipamento split convencional por split inverter pode reduzir o consumo de eletricidade em até 41% ao ano, considerando os níveis de eficiência energéticas vigentes. Os condicionadores do tipo inverter conseguem minimizar o consumo de energia elétrica, o que tornaria acessível hipoteticamente a utilização de equipamentos mais eficientes as classes menos favorecidas

    Geração de energia térmica por meio de fotobiorreator integrado em edifício comercial para aquecimento de água no clima subtropical úmido

    Get PDF
    Discussion regarding renewable energy generation is a relevant issue in the building sector. Some innovative strategies for renewable energy generation in this sector have emerged in the last decade, such as microalgae photobioreactors (PBRs). Bioenergy can be produced from biomass by the PBRs. Temperature is an important parameter of photobioreactors as this system can overheat and demand cooling. Thus, techniques have been developed to extract heat from PBRs and use it to meet the demands of the building. In this context, the present study performed an energy balance in a photobioreactor associated with a building under a Humid Subtropical climate (Brazil) – in Belo Horizonte, Minas Gerais. A thermoenergetic model was developed to obtain an annual temperature profile of a single photobioreactor. The results indicated that the PBR overheats concerning the optimal temperature range for microalgae biomass production. It was presented as an initial alternative to cool the photobioreactor. The volumetric flow rate of 0,016 L s-1 in the PBR and input cultivation temperature ranging from 20 to 24 °C could cool the PBR. The results presented seek to offer an initial alternative for the use of photobioreactors in buildings in Humid Subtropical climates. In addition, the annual PBR temperature profile obtained may guide future works.La generación de energía a través de fuentes alternativas se presenta como un desafío para el sector de la construcción civil. Los fotobiorreactores de microalgas (FBR) asociados a las fachadas de los edificios emergen como una estrategia innovadora para generar energía en los edificios. Las RBA pueden producir bioenergía a partir de biomasa. En este sentido, la temperatura de estos sistemas es importante para la producción de biomasa. Los fotobiorreactores pueden sobrecalentarse y requerir refrigeración para funcionar. Se utilizan técnicas para aprovechar el exceso de calor de los FBR y utilizarlo para las demandas del edificio. Así, el presente estudio realizó un balance energético en un fotobiorreactor asociado a un edificio bajo clima Subtropical Húmedo (Brasil) – en la ciudad de Belo Horizonte, Minas Gerais. Mediante la simulación termoenergética del edificio se obtuvo el perfil de temperatura anual del fotobiorreactor. Los resultados indicaron que el fotobiorreactor se sobrecalienta en relación al rango de temperatura ideal para la producción de biomasa de microalgas. Se ha presentado una propuesta inicial para enfriar el FBR. El caudal volumétrico de 0,016  Ls-1 en el FBR y la temperatura de entrada del cultivo que ingresa al fotobiorreactor que oscila entre 20 y 24 °C podrían enfriar el sistema. Los resultados aquí presentados buscan ofrecer una alternativa inicial para el uso de fotobiorreactores en edificaciones en climas Subtropicales Húmedos. Además, el perfil de temperatura anual FBR obtenido puede servir como base para trabajos futuros.Geração de energia por meio de fontes alternativas se apresenta como um desafio para o setor de construção civil. Fotobiorreatores de microalgas (FBRs) associados a fachada de edificações surgem como uma estratégia inovadora para geração de energia em prédios. Os FBRs podem produzir bioenergia a partir de biomassa. Nesse sentido, a temperatura desses sistemas é importante para a produção de biomassa. Os fotobiorreatores podem superaquecer e exigir resfriamento para sua operação. Técnicas são utilizadas para aproveitar calor excedente dos FBRs e utilizá-lo para as demandas da edificação. Assim, o presente estudo realizou um balanço de energia em um fotobiorreator associado a uma edificação sob clima Subtropical Úmido (Brasil) – na cidade de Belo Horizonte, Minas Gerais. Por meio da simulação termoenergético do prédio, foi obtido o perfil de temperatura anual do fotobiorreator. Os resultados indicaram que o fotobiorreator superaquece em relação à faixa de temperatura ideal para a produção de biomassa de microalgas. Uma proposta inicial para resfriar o FBR foi apresentada. A vazão volumétrica de 0,016 L s-1 no FBR e a temperatura de entrada da cultura que entra pelo fotobiorreator variando de 20 a 24 °C poderiam resfriar o sistema. Os resultados aqui apresentados buscam oferecer uma alternativa inicial para o uso de fotobiorreatores em edificações em clima Subtropical Úmido. Além disso, o perfil de temperatura FBR anual obtido pode servir de base para trabalhos futuros

    Investigação da carga térmica de resfriamento de uma edificação residencial multifamiliar por diferentes algoritmos de transferência de calor

    Get PDF
    O consumo de eletricidade referente ao ar condicionado tem relação direta com a carga de calor a ser retirada conforme a capacidade de refrigeração definida para um local específico. Neste contexto, os algoritmos de transferência de calor empregados na estimativa de carga térmica de edifícios são relevantes para auxiliar a definição do sistema de climatização de ambientes. Este estudo objetivou investigar a variabilidade da potência de resfriamento de edificações residenciais, por meio da aplicação de diferentes combinações de algoritmos disponíveis na biblioteca do programa ©Energy Plus, para cálculo da convecção interna/externa e balanço de energia. Foram possíveis trinta combinações que foram organizadas em três grupos de acordo com os algoritmos de convecção interna. Para a verificação dos resultados realizou-se a Análise de Variância (ANOVA) e o teste de Kruskal Wallis, afim de identificar diferenças significativas nos dados obtidos. Por meio dos resultados dos testes conclui-se que existe entre os grupos organizados pelo menos uma diferença significativa. Complementarmente, realizou-se também o teste de PostHoc para avaliar em quais grupos as diferenças divergiam mais. Desta forma, a escolha do método numérico mostrou influência significativa na definição dos sistemas de climatização artificial das edificações. Em suma, como contribuição, o presente trabalho buscou demonstrar o peso da escolha de diferentes combinações de algoritmos na estimativa da carga térmica de resfriamento como forma de auxiliar o processo de tomada de decisão ao se definir os seus inputs de simulaçã

    Investigação da carga térmica de resfriamento de uma edificação residencial multifamiliar por diferentes algoritmos de transferência de calor

    Get PDF
    Electricity consumption for air conditioning is directly related to the heat load to be removed according to the cooling capacity defined for a specific location. In this context, the heat transfer algorithms used in estimating the thermal load of buildings are relevant to help define the air conditioning system. This study aimed to investigate the variability of the cooling power of residential buildings, through the application of different combinations of algorithms available in the library of the ©Energy Plus program, to calculate the internal/external convection and energy balance. Thirty combinations were possible, which were organized into three groups according to the internal convection algorithms. To verify the results, the Analysis of Variance (ANOVA) and the Kruskal Wallis test were performed in order to identify significant differences in the data obtained. Through the results of the tests, it is concluded that there is at least one significant difference between the organized groups. Complementarily, the PostHoc test was also performed to assess in which groups the differences diverged the most. In this way, the choice of the numerical method showed significant influence in the definition of the artificial climate systems of the buildings. In short, as a contribution, the present work sought to demonstrate the weight of choosing different combinations of algorithms in estimating the cooling thermal load as a way of helping the decision-making process when defining its simulation inputs.El consumo de electricidad para aire acondicionado está directamente relacionado con la carga de calor a eliminar según la capacidad de refrigeración definida para una ubicación específica. En este contexto, los algoritmos de transferencia de calor utilizados en la estimación de la carga térmica de los edificios son relevantes para ayudar a definir el sistema de aire acondicionado. Este estudio tuvo como objetivo investigar la variabilidad de la potencia de enfriamiento de edificios residenciales, mediante la aplicación de diferentes combinaciones de algoritmos disponibles en la biblioteca del programa ©Energy Plus, para calcular la convección interna/externa y el balance energético. Eran posibles treinta combinaciones, que se organizaron en tres grupos de acuerdo con los algoritmos de convección interna. Para verificar los resultados se realizó el Análisis de Varianza (ANOVA) y la prueba de Kruskal Wallis con el fin de identificar diferencias significativas en los datos obtenidos. A través de los resultados de las pruebas se concluye que existe al menos una diferencia significativa entre los grupos organizados. Complementariamente, también se realizó la prueba Post Hoc para evaluar en qué grupos divergían más las diferencias. De esta forma, la elección del método numérico mostró una influencia significativa en la definición de los sistemas de clima artificial de los edificios. En resumen, como contribución, el presente trabajo buscó demostrar el peso de elegir diferentes combinaciones de algoritmos en la estimación de la carga térmica de enfriamiento como una forma de ayudar al proceso de toma de decisiones al definir sus entradas de simulación.O consumo de eletricidade referente ao ar condicionado tem relação direta com a carga de calor a ser retirada conforme a capacidade de refrigeração definida para um local específico. Neste contexto, os algoritmos de transferência de calor empregados na estimativa de carga térmica de edifícios são relevantes para auxiliar a definição do sistema de climatização de ambientes. Este estudo objetivou investigar a variabilidade da potência de resfriamento de edificações residenciais, por meio da aplicação de diferentes combinações de algoritmos disponíveis na biblioteca do programa ©Energy Plus, para cálculo da convecção interna/externa e balanço de energia. Foram possíveis trinta combinações que foram organizadas em três grupos de acordo com os algoritmos de convecção interna. Para a verificação dos resultados realizou-se a Análise de Variância (ANOVA) e o teste de Kruskal Wallis, afim de identificar diferenças significativas nos dados obtidos. Por meio dos resultados dos testes conclui-se que existe entre os grupos organizados pelo menos uma diferença significativa. Complementarmente, realizou-se também o teste de PostHoc para avaliar em quais grupos as diferenças divergiam mais. Desta forma, a escolha do método numérico mostrou influência significativa na definição dos sistemas de climatização artificial das edificações. Em suma, como contribuição, o presente trabalho buscou demonstrar o peso da escolha de diferentes combinações de algoritmos na estimativa da carga térmica de resfriamento como forma de auxiliar o processo de tomada de decisão ao se definir os seus inputs de simulaçã

    Diclofenac Administration after Physical Training Blunts Adaptations of Peripheral Systems and Leads to Losses in Exercise Performance: In Vivo and In Silico Analyses

    Get PDF
    Recovery in athletes is hampered by soreness and fatigue. Consequently, nonsteroidal antiinflammatory drugs are used as an effective strategy to maintain high performance. However, impact of these drugs on adaptations induced by training remains unknown. This study assessed the effects of diclofenac administration (10 mg/kg/day) on rats subjected to an exhaustive test, after six weeks of swimming training. Over the course of 10 days, three repeated swimming bouts were performed, and diclofenac or saline were administered once a day. Trained animals exhibited higher muscle citrate synthase and lower plasma creatinine kinase activities as compared to sedentary animals, wherein diclofenac had no impact. Training increased time to exhaustion, however, diclofenac blunted this effect. It also impaired the increase in plasma and liver interleukin-6 levels. The trained group exhibited augmented catalase, glutathione peroxidase, and glutathione reductase activities, and a higher ratio of reduced-to-oxidized glutathione in the liver. However, diclofenac treatment blunted all these effects. Systems biology analysis revealed a close relationship between diclofenac and liver catalase. These results confirmed that regular exercise induces inflammation and oxidative stress, which are crucial for tissue adaptations. Altogether, diclofenac treatment might be helpful in preventing pain and inflammation, but its use severely affects performance and tissue adaptatio

    Association between obesity and knee osteoarthritis in users of brazilian unified national health system

    Get PDF
    Verify possible associations between obesity and knee OA in users of Brazilian Unified National Health System (Sistema Único de Saúde - SUS) of primary care network in Catalão-GO, Brazil. This is an observational study conducted in 2014 and 2015. A total of 81 volunteers from the Basic Attention Network in the city of Catalão, with body mass index (BMI) over 30 kg/m2 in both sexes, age between 40 and 60 years, and OA on radiological examination of the knee. Obesity was classified according to BMI. The diagnosis of osteoarthritis (OA) was made clinically and by radiography according to Kellgren radiological classification. The level of physical activity was assessed using the Baecke questionnaire and the Gordon Functional Classification. The volunteers underwent an anthropometric evaluation and physical examination with inspection and palpation of the joint and subsequent radiological examination of the knee. The volunteers answered a questionnaire on the level of physical activity and functional classification. Data analysis was performed using Fisher’s exact test or chi-square test was used for comparisons of two proportions. In comparisons of continuous variables, Student’s t-test or the nonparametric Wilcoxon-Mann-Whitney test was used. The level of significance was set to 5%. Practice of regular physical exercise decreases functional impairment in obese individuals with knee OA. The weight variable demonstrated a strong association with the severity of OA and degree of functionality of patients. Obesity and OA durations and lack of patient guidance are variables that may contribute to the progression of knee OA. Although the incidence among men is lower, they are more severely affected and anthropometric evaluation and physical examination are an efficacy implementations for Brazilian users of SUS

    Needle visualization during ultrasound-guided puncture: image optimization

    Get PDF
    Abstract Background Obtaining an adequate image of the needle by ultrasound reduces complications resulting from punctures, increasing patient safety and reducing hospitalization costs. Objectives To verify human perception in relation to number of pixels, while also identifying the best puncture angle and which needle should be used, and to evaluate whether there is a difference if needle visualization software is used. Methods 20 images were analyzed by 103 students who classified them as being sufficient or insufficient and were compared with the quality observed using photoshop. We evaluated whether there were differences between puncture angles of less than 45º and more than 45º, between IV catheter and introducer needles, and between images obtained with and without visualization software. Results There was a higher percentage of sufficient ratings for images those that had more than 60 pixels and when the puncture angle was less than 45º, with significant associations between students’ evaluations and each of these groups (p < 0.001). The percentages of images classified as sufficient were higher for images in which a IV catheter was used and also higher for those using the needle visualization software, with significant associations between the results for students’ classifications and each of these groups (p < 0.001). Conclusions The human eye classifies an image as sufficient according to higher numbers of pixels. Images of punctures at angles smaller than 45º in relation to the surface, of punctures performed with a IV catheter, and when using specific visualization software are also better detected by the human eye

    Surgical results of coronary artery bypass grafting without cardiopulmonary bypass: analysis of 3,410 patients Resultados cirúrgicos na revascularização do miocárdio sem circulação extracorpórea: análise de 3.410 pacientes

    Full text link
    OBJECTIVES: Over the past few years, great strides have been made in off-pump coronary surgery. This progress is due to a combination of the advances in surgical techniques and the development of instruments that make it possible to perform this procedure in the most varied situations. This is a retrospective study, the purpose of which is to assess our experience with this procedure over the last eleven and a half years. The authors underscore the rapid progress of the method in recent years and report on its indications, contraindications and results. METHODS: In the period from August 1991 to December 2003, 3,410 consecutively patients suffering from angina pectoris were submitted to off-pump coronary surgery. Ages ranged from 13 to 93 years, with a mean of 63 ± 12.0 years. Males accounted for 58% of the cases. The angina was rated according to the criteria of the Canadian Cardiovascular Society, 6.1% of the patients being in Class I, 6.8% in Class II, 46.3% in Class III and 40.8% in Class IV. RESULTS: Intraoperative mortality was low (0.4%). Hospital mortality (30 postoperative days) was 2.5%. Mortality and morbidity among the octogenarian patients were extremely low compared with patients operated on with cardiopulmonary bypass (CPB) (2.2% versus 12.6%) (p<0.001). Postoperative complications regarded as nonfatal occurred in 7.6%. In the final year no difference was observed between the number of conduits in the patients operated on with and without CPB [with CPB 2.8 ± 1.2 and without 2.8 ± 0.8 (NS)]. Acute myocardial infarction was the most frequent complication, occurring in 2.7% of the patients. The mean time in the intensive care unit was 22.3 hours. CONCLUSIONS: Off-pump coronary surgery, employed as a revascularization technique in patients requiring multiple grafts, is a reproducible procedure, the results of which are similar to those obtained from conventional surgery with CPB. In the present series it was possible to perform coronary artery bypass grafting without CPB in 95% of the patients, thus making all patients with indication for grafting potential candidates for the procedure without CPB.<br>OBJETIVO: Nos últimos anos, tem-se observado um grande avanço na cirurgia de revascularização miocárdica sem circulação extracorpórea (RMSCEC). Esse desenvolvimento deveu-se à combinação dos avanços da técnica cirúrgica e ao desenvolvimento de instrumentos que possibilitam a realização deste procedimento nas mais variadas situações. Este é um estudo retrospectivo, que visa avaliar nossa experiência com este procedimento nos últimos 11,5 anos. Os autores enfatizam o rápido progresso do método nos últimos anos, suas indicações, contra-indicações e resultados. MÉTODO: No período de agosto de 1991 e dezembro de 2002, 3.410 pacientes consecutivos, portadores de angina do peito, foram submetidos a cirurgia de revascularização miocárdica sem circulação extracorpórea. A idade variou de 13 a 93 anos (63 12,0 anos), sendo 58% dos pacientes do sexo masculino. A angina foi classificada segundo a Canadian Cardiovascular Society, sendo 6,1% na classe I, 6,8% na classe II, 46,3% na classe III e 40,8% na classe IV. RESULTADOS: A mortalidade intra-operatória foi baixa (0,4%). A mortalidade hospitalar (trinta dias de pós-operatório) foi de 2,58%. A mortalidade e morbidade, no grupo dos pacientes octogenários, foram extremamente baixas em relação aos pacientes operados com circulação extracorpórea (2,2% x 12,6%) (p<0,001). As complicações pós-operatórias que não resultaram em óbito foram de 7,6%. No último ano, não observamos diferença entre o número de condutos nos pacientes operados com e sem CEC [com CEC 2,81,2 e sem CEC 2,80,8 (NS)]. Infarto agudo do miocárdio foi a complicação não fatal mais freqüente, observada em 2,8% dos pacientes. O tempo médio de permanência na UTI foi de 22,3 horas. CONCLUSÕES: A RMSCEC, usada como técnica de revascularização em pacientes multiarteriais, é um procedimento reproduzível e apresenta resultados semelhantes aos obtidos com a operação convencional com CEC. Nesta série foi possível revascularizar o miocárdio sem circulação extracorpórea em mais de 95% dos pacientes, tornando assim, a princípio, todos os pacientes, com indicação de revascularização miocárdica, potenciais candidatos à operação de RMSCEC
    corecore