26 research outputs found

    Plasma free DNA: Evaluation of temperature-associated storage effects observed for Roche Cell-Free DNA collection tubes

    Get PDF
    Introduction: Standardized pre-analytical blood sample procedures for the analysis of circulating cell-free DNA (ccfDNA) are still not available. Therefore, the present study aimed at evaluating the impact of storage conditions related to different times (24 and 48 h) and temperatures (room temperature (RT) and 4 - 8 °C) on the plasma ccfDNA concentration of blood samples drawn into Cell-Free DNA collection tubes (Roche Diagnostics GmbH, Mannheim, Germany). Materials and methods: Venous blood from 30 healthy individuals was collected into five 8.5 mL Cell-Free DNA Collection Tubes (Roche Diagnostics GmbH) each. Plasma samples were processed at time point of blood collection (tube 1), and after storage under the following conditions: 24 h at RT (tube 2) or 4-8 °C (tube 3), and 48 h at RT (tube 4) or 4 - 8 °C (tube 5). Circulating cell-free DNA concentrations were determined by EvaGreen chemistry-based droplet digital PCR (ddPCR). Results: No statistically significant differences between median (interquartile range) plasma ccfDNA concentrations (ng/mL) at time point of blood collection (3.17 (2.13 – 3.76)) and after storage for 24 h (RT: 3.02 (2.41 – 3.68); 4-8 °C: 3.21 (2.19 – 3.46)) and 48 h (RT: 3.13 (2.10 – 3.76); 4-8 °C: 3.09 (2.19 – 3.50)) were observed (P values from 0.102 – 0.975). Conclusions: No unwanted release of genomic DNA from white blood cells could be detected in plasma samples after tube storage for 24 and 48 h regardless of storage temperature

    Evaluation of a commercial liquid-chromatography high-resolution mass-spectrometry method for the determination of hepcidin-25

    Get PDF
    Introduction: Reliable determination of hepcidin-25, a key regulator of iron metabolism, is important. This study aimed at evaluating the performance of the Hepcidin-25 Liquid Chromatography-Tandem Mass-Spectrometry (LC-MS/MS) Kit (Immundiagnostik AG, Bensheim, Germany) for quantification of the hepcidin-25 protein. Materials and methods: Precision, accuracy, linearity, and preanalytical requirements of the liquid-chromatography high-resolution massspectrometry (LC-HR-MS) method were evaluated. The imprecision and bias acceptance criteria were defined ≀ 15%. We investigated sample stability at room temperature (RT) and after repeated freeze and thaw cycles. Additionally, we assessed serum hepcidin-25 concentrations of 165 healthy adults referred for a medical check-up. Results: The hepcidin-25 LC-MS/MS assay was linear over the concentration range of 3 – 200 ng/mL. Within- and between-run precision ranged between 1.9 – 8.6% and 5.1 – 12.4%, respectively. The mean bias of the low and high control material was - 2.7% and 2.1%, respectively. At RT, serum samples were stable for 3 h (mean bias + 0.3%). After two and three freeze and thaw cycles, hepcidin-25 concentrations showed a bias of +8.0 and + 20%, respectively. Of 165 healthy adults, 109 females had a significantly lower median of 8.42 (range: 1.00 – 60.10) ng/mL compared to 56 males with 15.76 (range: 1.50 – 60.50) ng/mL (P = 0.002). Conclusions: The hepcidin-25 LC-MS/MS kit shows a broad analytical range and meets the imprecision and bias acceptance criteria of ≀ 15%. Serum samples can be stored at RT for 3 h and resist up to two freeze and thaw cycles

    Pneumatic tube system transport does not alter platelet function in optical and whole blood aggregometry, prothrombin time, activated partial thromboplastin time, platelet count and fibrinogen in patients on anti-platelet drug therapy

    Get PDF
    Introduction: The aim of this study was to assess pneumatic tube system (PTS) alteration on platelet function by the light transmission aggregometry (LTA) and whole blood aggregometry (WBA) method, and on the results of platelet count, prothrombin time (PT), activated partial thromboplastin time (APTT), and fibrinogen. Materials and methods: Venous blood was collected into six 4.5 mL VACUETTEÂź 9NC coagulation sodium citrate 3.8% tubes (Greiner Bio-One International GmbH, KremsmĂŒnster, Austria) from 49 intensive care unit (ICU) patients on dual anti-platelet therapy and immediately hand carried to the central laboratory. Blood samples were divided into 2 Groups: Group 1 samples (N = 49) underwent PTS (4 m/s) transport from the central laboratory to the distant laboratory and back to the central laboratory, whereas Group 2 samples (N = 49) were excluded from PTS forces. In both groups, LTA and WBA stimulated with collagen, adenosine-5’-diphosphate (ADP), arachidonic acid (AA) and thrombin-receptor-activated-peptide 6 (TRAP-6) as well as platelet count, PT, APTT, and fibrinogen were performed. Results: No statistically significant differences were observed between blood samples with (Group 1) and without (Group 2) PTS transport (P values from 0.064 – 0.968). The AA-induced LTA (bias: 68.57%) exceeded the bias acceptance limit of ? 25%. Conclusions: Blood sample transportation with computer controlled PTS in our hospital had no statistically significant effects on platelet aggregation determined in patients with anti-platelet therapy. Although AA induced LTA showed a significant bias, the diagnostic accuracy was not influenced

    Method evaluation study of a new generation of vitamin D assays

    Get PDF
    Introduction: Recently several diagnostic manufacturers have launched new 25-hydroxy-vitamin D (25[OH]D) assays, which are aligned to the National Institute of Standards and Technology (NIST) Standard Reference Materials (SRM) (NIST, Gaithersburg, Maryland). The aim of this study was to compare the performance of one liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, one enzyme linked immunosorbent assay (ELISA), and one recalibrated and previous version of a chemiluminescence immunoassay (CLIA). Material and methods: Serum-aliquots of 198 patient samples from routine 25(OH)D analysis were measured by the ClinMassÂź LC-MS/MS Complete Kit (RECIPE Chemicals + Instruments GmbH, Munich, Germany), the ORGENTEC 25(OH)D3/D2 ELISA (ORGENTEC Diagnostika GmbH, Mainz, Germany), the recalibrated Immunodiagnostic Systems (IDS)-iSYS 25(OH)DS and the previous used IDS-iSYS 25(OH)D CLIA (Immunodiagnostic Systems Ltd, Boldon, United Kingdom). Bland-Altman and Deming regression analyses were calculated for methods comparison of all tested 25(OH)D assays. The LC-MS/MS method was defined as the reference method. Within-run and between-run precision measurements were performed for all methods with three different concentration levels. Results: Compared to the LC-MS/MS method, the new IDS-iSYS 25(OH)DS and ORGENTEC 25(OH)D3/D2 assay demonstrated mean relative biases of 16.3% and 17.8%. The IDS-iSYS 25(OH)D assay showed the lowest mean bias of 1.5%. Deming regression analyses of the recalibrated IDS-iSYS 25(OH)DS and the ORGENTEC 25(OH)D3/D2 assay showed proportional differences, when compared to the reference method. All assays showed a within-run and between-run imprecision of ≀ 20% at each of the evaluated concentration levels. Conclusions: The evaluated standardized immunoassays and LC-MS/MS are useful methods for measuring 25(OH)D serum-levels in clinical laboratories

    Histamine Intolerance Originates in the Gut

    No full text
    Histamine intolerance (HIT) is assumed to be due to a deficiency of the gastrointestinal (GI) enzyme diamine oxidase (DAO) and, therefore, the food component histamine not being degraded and/or absorbed properly within the GI tract. Involvement of the GI mucosa in various disorders and diseases, several with unknown origin, and the effects of some medications seem to reduce gastrointestinal DAO activity. HIT causes variable, functional, nonspecific, non-allergic GI and extra-intestinal complaints. Usually, evaluation for HIT is not included in differential diagnoses of patients with unexplained, functional GI complaints or in the here-listed disorders and diseases. The clinical diagnosis of HIT is challenging, and the thorough anamnesis of all HIT-linked complaints, using a standardized questionnaire, is the mainstay of HIT diagnosis. So far, DAO values in serum have not been established to correlate with DAO activity in the gut, but the diagnosis of HIT may be supported with determination of a low serum DAO value. A targeted dietary intervention, consisting of a histamine-reduced diet and/or supplementation with oral DAO capsules, is helpful to reduce HIT-related symptoms. This manuscript will present why histamine should also be taken into account in the differential diagnoses of patients with various diseases and disorders of unknown origin, but with association to functional gastrointestinal complaints. In this review, we discuss currently increasing evidence that HIT is primarily a gastrointestinal disorder and that it originates in the gut

    Lactose Malabsorption Testing in Daily Clinical Practice: A Critical Retrospective Analysis and Comparison of the Hydrogen/Methane Breath Test and Genetic Test ( C

    No full text
    The aim of this study was to establish a retrospective evaluation and comparison of the hydrogen/methane (H2/CH4) breath test and genetic test (C/T−13910 polymorphism) results in lactose malabsorption testing. In total 263 consecutive patients with suspected lactose malabsorption were included in this study. They underwent the H2/CH4 breath test following the ingestion of 50 g lactose and were tested for the C/T−13910 polymorphism. In total 51 patients (19.4%) had a C/C−13910 genotype, indicating primary lactose malabsorption. Only 19 patients (7.2%) also had a positive H2/CH4 breath test. All in all 136 patients (51.69%) had a C/T−13910 and 76 patients (28.91%) a T/T−13910 genotype, indicating lactase persistence. Four patients (1.5%) with the C/T−13910 genotype and one patient (0.4%) with the T/T−13910 genotype had a positive H2/CH4 breath test result, indicating secondary lactose malabsorption. Cohen's Kappa measuring agreement between the two methods was 0.44. Twenty patients (7.6%) with a positive H2/CH4 peak within 60 minutes after lactose ingestion were classified as patients with lactose-dependent small intestinal bacterial overgrowth (SIBO). In conclusion, only moderate agreement between the breath test and the genetic test was shown. Secondary lactose malabsorption as well as preanalytical limitations of the combined H2/CH4 breath test procedure can cause discrepant results. This trial is registered with K-42-13

    Implementation of a Dual-Column Liquid Chromatography-Tandem Mass-Spectrometry Method for the Quantification of Isavuconazole in Clinical Practice

    No full text
    Objectives Therapeutic drug monitoring (TDM) of isavuconazole, which is a novel broad-spectrum antimycoticum against invasive fungal infections, ensures an effective exposure of the drug and minimizes the risk of toxicity. This study is aimed at evaluating the analytical performance of a dual-column liquid chromatography-tandem mass-spectrometry (LC-MS/MS) method for isavuconazole quantification. Materials and Methods The method was performed on a Voyager TSQ Quantum triple quadrupole instrument equipped with an Ultimate 3000 chromatography system (Thermo Fisher Scientific, San Jose, California, United States). Analytical and preanalytical requirements of the isavuconazole LC-MS/MS method were evaluated. Sample stability measurements were performed at room temperature (RT) and in serum tubes with separator gel. Results The isavuconazole LC-MS/MS method was linear over the concentration range of 0.2 to 12.8 mg/L. The coefficient of determination (r 2) always exceeded 0.999. Within- and between-run precision ranged between 1.4 to 2.9% and 1.5 to 3.0%, the recovery between 93.9 and 102.7%. At RT, serum samples were stable for 3 days. Isavuconazole serum concentrations were significantly lower after incubation (18 hours) in serum tubes with separator gel at RT. Conclusion The dual-column isavuconazole LC-MS/MS is a reliable tool for the TDM of isavuconazole. Serum samples are stable for at least 3 days and should be collected in tubes without separator gel

    Functional Abdominal Pain Disorders in Children May Be Associated with Food Intolerance/Malabsorption

    No full text
    Functional abdominal pain disorders (FAPDs) are among the most common types of chronic pain disorders in children. FAPD symptoms are characterized by chronic abdominal pain and changed bowel movements. The pathophysiology of FAPDs in children is unknown, but these conditions may have an imprecise clinical overlap to food intolerance/malabsorption. We report on 51 consecutive children (23/28 males/females; median age 15.3 years) with investigated FAPDs from 2017 to 2022 in this retrospective pilot study. Small intestinal biopsies in children demonstrated the association of lactase and diamine oxidase (DAO), which prompted us to perform hydrogen (H2) breath tests for lactose intolerance (LIT) and determine serum DAO for the evaluation of histamine intolerance (HIT) in pediatric patients with FAPDs. To complete the food intolerance/malabsorption evaluation tests, we included a search for antibodies against tissue transglutaminase to find celiac disease (CD), performed H2 breath tests to detect fructose malabsorption (FM), and conducted a search for IgA antibodies against H. pylori infection. The results demonstrate that all 51 children evaluated were diagnosed with food intolerance/malabsorption and/or various combinations thereof. Seven children showed FM, eight of the children had HIT, and eight children had LIT. The other children had combinations: thirteen children (25.5%) had HIT and LIT, seven children (9.8%) had FM with HIT, five children (13.7%) had FM and LIT, and three children (5.9%) had a triple combination of FM, HIT, and LIT. By describing this method of personalized investigation for food intolerance/malabsorption in children with FAPDs, we demonstrate that functional abdominal pain disorders may be associated with food intolerance/malabsorption. After such diagnosis in this pediatric population, a registered dietitian helped to establish a reduction and/or exclusion diet individually tailored to their symptomatology
    corecore