42 research outputs found

    Systolic Blood Pressure and Effects of Screening for Atrial Fibrillation With Long-Term Continuous Monitoring (a LOOP Substudy)

    Get PDF
    BACKGROUND: Hypertension is a well-known risk factor for atrial fibrillation (AF) and stoke, but data on the interaction between systolic blood pressure (SBP) and effects of AF screening are lacking. METHODS: The LOOP Study randomized AF-naïve individuals aged 70 to 90 years with additional stroke risk factors to either screening with implantable loop recorder (ILR) and anticoagulation initiation upon detection of AF episodes ≥6 minutes, or usual care. In total, 5997 participants with available baseline SBP measurements were included in this substudy. Outcomes were analyzed according to the time-to-first-event principle using cause-specific Cox models. RESULTS: The hazard ratio of stroke or systemic arterial embolism for ILR versus control decreased with increasing SBP. ILR screening yielded a 44% risk reduction of stroke or systemic arterial embolism among participants with SBP ≥150 mm Hg (adjusted hazard ratio, 0.56 [0.37–0.83]). Within the ILR group, SBP≥150 mm Hg was associated with a higher incidence of AF episodes ≥24 hours than lower SBP (adjusted hazard ratio, 1.70 [1.08–2.69]) but not with the overall occurrence of AF (adjusted P>0.05). CONCLUSIONS: The impact of AF screening on thromboembolic events increased with increasing blood pressure. SBP≥150 mm Hg was associated with a >1.5-fold increased risk of AF episodes ≥24 hours, along with an almost 50% risk reduction of stroke or systemic arterial embolism by ILR screening compared to lower blood pressure. These findings should be considered hypothesis-generating and warrant further study. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique Identifier: NCT02036450

    Severity and Etiology of Incident Stroke in Patients Screened for Atrial Fibrillation vs Usual Care and the Impact of Prior Stroke:A Post Hoc Analysis of the LOOP Randomized Clinical Trial

    Get PDF
    IMPORTANCE: Atrial fibrillation (AF) screening trials have failed to demonstrate a significant reduction in stroke risk. The impact on stroke severity and the importance of prior strokes are unknown. OBJECTIVE: To assess stroke characteristics in patients undergoing implantable loop recorder (ILR) screening for AF vs usual care and assess the importance of prior stroke. DESIGN, SETTING, AND PARTICIPANTS: This was a post hoc analysis of the Atrial Fibrillation Detected by Continuous Electrocardiogram Monitoring Using Implantable Loop Recorder to Prevent Stroke in High-Risk Individuals (LOOP) randomized clinical trial. Persons 70 years or older without known AF but diagnosed with 1 or more of the following, hypertension, diabetes, heart failure, or prior stroke, were screened for inclusion. Four sites in Denmark recruited participants by letter between January 31, 2014, and May 17, 2016. The median (IQR) follow-up period was 65 (59-70) months. Data were analyzed from April 1 to May 31, 2022. INTERVENTIONS: ILR screening for AF and anticoagulation initiation if AF duration of 6 minutes or longer was detected (ILR group) vs usual care (control group). MAIN OUTCOMES AND MEASURES: Adjudicated stroke, classified according to the modified Rankin Scale (mRS) using a score of 3 or more as a cutoff for severe (disabling or lethal) stroke, and according to the Trial of Org 10172 in Acute Stroke Treatment (TOAST) classification for ischemic strokes. RESULTS: A total of 6205 individuals were screened for inclusion, and 6004 were randomized and included in the analysis; 4503 participants (75%; mean [SD] age, 74.7 [4.1] years; 2375 male [52.7%]) were assigned to the control group and 1501 participants (25%; mean [SD] age, 74.7 [4.1] years; 792 male [52.8%]) were assigned to the ILR group. A total of 794 of 4503 participants (17.6%) in the control group had a history of prior stroke compared with 262 of 1501 participants (17.5%) in the ILR group. During follow-up, AF was diagnosed in 1027 participants (control group, 550 [12%] vs ILR group, 477 [32%]), and anticoagulation was initiated in 89% of these (910). A total of 315 participants (5.2%) had a stroke (control group, 249 [5.5%] vs ILR group, 66 [4.4%]), and the median (IQR) mRS score was 2 (1-3) with no difference across the groups. A total of 272 participants (4.5%) had ischemic stroke (control group, 217 [4.8%] vs ILR group, 55 [3.7%]), and 123 (2.0%) had severe stroke (control group, 100 [2.2%] vs ILR group, 23 [1.5%]), and the hazard ratios comparing the control and ILR groups were 0.76 (95% CI, 0.57-1.03; P = .07) and 0.69 (95% CI, 0.44-1.09; P = .11), respectively. For participants without prior stroke, the hazard ratios were 0.68 (95% CI, 0.48-0.97; P = .04) and 0.54 (95% CI, 0.30-0.97; P = .04), respectively. CONCLUSIONS AND RELEVANCE: This post hoc analysis of the LOOP randomized clinical trial found that ILR screening for AF did not result in a significant decrease in ischemic or severe strokes compared with usual care. Exploratory subgroup analyses indicated a possible reduction of these outcomes among participants without prior stroke. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT0203645

    Potential role of conventional and speckle-tracking echocardiography in the screening of structural and functional cardiac abnormalities in elderly individuals:Baseline echocardiographic findings from the LOOP study

    Get PDF
    BACKGROUND: Elderly individuals occupy an increasing part of the general population. Conventional and speckle-tracking transthoracic echocardiography may help guide risk stratification in these individuals. The purpose of this study was to evaluate the potential utility of conventional and speckle-tracking echocardiography in the screening of cardiac abnormalities in the elderly population. METHODS: Two cohorts of elderly individuals (sample size: 1441 and 944) were analyzed, who were part of a randomized controlled clinical trial (LOOP study) and of an observational study (Copenhagen City Heart Study), recruiting participants from the general population >70 years of age with cardiovascular risk factors (arterial hypertension, diabetes mellitus, heart failure, or prior stroke) and sinus rhythm. Participants underwent a comprehensive transthoracic echocardiographic examination, including myocardial speckle tracking. Cardiac abnormalities were defined according to the ASE/EACVI guidelines. RESULTS: Structural cardiac abnormalities such as left ventricular (LV) remodeling, mitral annular calcification (MAC), and aortic valve sclerosis (with or without stenosis) were highly prevalent in the LOOP study (40%, 39%, and 27%, respectively). Moreover, a high prevalence of functional cardiac alterations such as LV diastolic dysfunction (LVDD), abnormal LV longitudinal systolic strain (GLS), and abnormal left atrial (LA) reservoir strain was present in the LOOP study (27%, 18%, and 9%, respectively). Likewise, the rate of LVDD, abnormal GLS, and abnormal LA reservoir strain was comparable in the validation sample from the Copenhagen City Heart Study. In line with these findings, subjects with LV remodeling, MAC, and aortic valve changes had a higher prevalence of LVDD, abnormal GLS, and abnormal LA reservoir strain than those without structural cardiac alterations. CONCLUSION: The findings of this study highlight the potential clinical utility of conventional and speckle-tracking echocardiography in the screening of structural and functional cardiac abnormalities in the elderly population. Further studies are warranted to determine the prognostic relevance of these findings

    Early diagnosis and better rhythm management to improve outcomes in patients with atrial fibrillation: the 8th AFNET/EHRA consensus conference

    Get PDF
    Aims Despite marked progress in the management of atrial fibrillation (AF), detecting AF remains difficult and AF-related complications cause unacceptable morbidity and mortality even on optimal current therapy.Methods and results This document summarizes the key outcomes of the 8th AFNET/EHRA Consensus Conference of the Atrial Fibrillation NETwork (AFNET) and the European Heart Rhythm Association (EHRA). Eighty-three international experts met in Hamburg for 2 days in October 2021. Results of the interdisciplinary, hybrid discussions in breakout groups and the plenary based on recently published and unpublished observations are summarized in this consensus paper to support improved care for patients with AF by guiding prevention, individualized management, and research strategies. The main outcomes are (i) new evidence supports a simple, scalable, and pragmatic population-based AF screening pathway; (ii) rhythm management is evolving from therapy aimed at improving symptoms to an integrated domain in the prevention of AF-related outcomes, especially in patients with recently diagnosed AF; (iii) improved characterization of atrial cardiomyopathy may help to identify patients in need for therapy; (iv) standardized assessment of cognitive function in patients with AF could lead to improvement in patient outcomes; and (v) artificial intelligence (AI) can support all of the above aims, but requires advanced interdisciplinary knowledge and collaboration as well as a better medico-legal framework.Conclusions Implementation of new evidence-based approaches to AF screening and rhythm management can improve outcomes in patients with AF. Additional benefits are possible with further efforts to identify and target atrial cardiomyopathy and cognitive impairment, which can be facilitated by AI.</p
    corecore