5,482 research outputs found

    Expected sensitivity of ARGO-YBJ to detect point gamma-ray sources

    Full text link
    ARGO-YBJ is a full coverage air shower detector currently under construction at the Yangbajing Laboratory (4300 m a.s.l., Tibet, China). First data obtained with a subset of the apparatus will be available in summer 2003 while the full detector operation is expected in 2005. One of the main aims of ARGO-YBJ is the observation of gamma-ray sources, at an energy threshold of a few hundreds GeV. In this paper we present the expected sensitivity to detect point gamma ray sources, with particular attention to the Crab Nebula. According to our simulations a Crab-like signal could be detected in one year of operation with a statistical significance of 10 standard deviations, without any gamma/hadron discrimination.Comment: 4 pages, 2 Postscript figure

    Surgical management of rhinosinusitis in onco-hematological patients

    Get PDF
    ObjectivesIn onco-hematological diseases, the incidence of paranasal sinuses infection dramatically increase and requires a combination of medical and surgical therapy. Balloon dilatation surgery (DS) is a minimally invasive, tissue preserving procedure. The study evaluates the results of DS for rhinosinusitis in immunocompromised patients.MethodsA retrospective chart review was conducted in 110 hematologic patients with rhinosinusitis. Twenty-five patients were treated with DS technique and 85 patients with endoscopic sinus surgery (ESS). We considered the type of anesthesia and the extent of intra- and postoperative bleeding. Patients underwent Sino-Nasal Outcome Test (SNOT-20) to evaluate changes in subjective symptoms and global patient assessment (GPA) questionnaire to value patient satisfaction.ResultsLocal anesthesia was employed in 8 cases of DS and in 15 of ESS. In 50 ESS patients, an anterior nasal packing was placed and in 12 cases a repacking was necessary. In the DS group, nasal packing was required in 8 cases and in 2 cases a repacking was placed (P=0.019 and P=0.422, respectively). The SNOT-20 change score showed significant improvement of health status in both groups. However the DS group showed a major improvement in 3 voices: need to blow nose, runny nose, and facial pain/pressure. The 3-month follow-up GPA questionnaire showed an higher satisfaction of DS group.ConclusionBalloon DS represents a potentially low aggressive treatment and appears to be relatively safe and effective in onco-hematologic patients. All these remarks may lead the surgeon to consider a larger number of candidates for surgical procedure

    A general estimator of the primary cosmic ray energy with the ARGO-YBJ experiment

    Get PDF
    The determination of the primary cosmic ray all-particle spectrum with ground-based air shower experiments usually depends on the assumed elemental composition and hadronic interaction model. Here we show that an energy estimator independent of the primary mass composition can be defined by means of shower parameters measured in the core region, as carried out in the ARGO-YBJ experiment. The energy resolution is <10% above 100 TeV and gets better with energy increasing. Being insensitive to the number of muons, this energy determination has only a weak dependence on the hadronic interaction model. The features of this energy estimator have been validated by extensive MC simulations and used in the analysis of the ARGO-YBJ data

    Retropharyngeal Lipoma Causing Sleep Apnea Syndrome

    Get PDF

    Surface doping in T6/ PDI-8CN2 Heterostructures investigated by transport and photoemission measurements

    Full text link
    In this paper, we discuss the surface doping in sexithiophene (T6) organic field-effect transistors by PDI-8CN2. We show that an accumulation heterojunction is formed at the interface between the organic semiconductors and that the consequent band bending in T6 caused by PDI-8CN2 deposition can be addressed as the cause of the surface doping in T6 transistors. Several evidences of this phenomenon have been furnished both by electrical transport and photoemission measurements, namely the increase in the conductivity, the shift of the threshold voltage and the shift of the T6 HOMO peak towards higher binding energies.Comment: 5 pages, 5 figure

    Vestibulo-Ocular Reflex Modification after Virtual Environment Exposure

    Get PDF
    Immersion in an illusory world is possible by means of virtual reality (VR), where environmental perception is modi bff c1c ed by artificial sensorial stimulation. The application of VR for the assessment and rehabilitation of pathologies affecting the vestibular system, in terms of both diagnosis and care, could represent an interesting new line of research. Our perception of reality is in fact based on static and dynamic spatial information perceived by our senses. During head movements in a virtual environment the images on the display and the labyrinthine information relative to the head angular accelerations differ and therefore a visuo-vestibular conflict is present. It is known that mismatches between visual and labyrinthine information may modify the vestibulo-oculomotor reflex (VOR) gain. We studied the post-immersion modifications in 20 healthy subjects (mean age 25 years) exposed to a virtual environment for 20 min by wearing a head-mounted display. VOR gain and phase were measured by means of harmonic sinusoidal stimulation in the dark before, at the end of and 30 min after VR exposure. A VOR gain reduction was observed in all subjects at the end of VR exposure which disappeared after 30 min. Our data show that exposure to a virtual environment can induce a temporary modi bff c1c cation of the VOR gain. This bff c1c nding can be employed to enable an artificial, instrumental modification of the VOR gain and therefore opens up new perspectives in the assessment and rehabilitation of vestibular diseases

    Rain evaporation rate estimates from dual-wavelength lidar measurements and intercomparison against a model analytical solution

    Get PDF
    Rain evaporation, while significantly contributing to moisture and heat cloud budgets, is a still poorly understood process with few measurements presently available. Multiwavelength lidars, widely employed in aerosols and clouds studies, can also provide useful information on the microphysical characteristics of light precipitation, for example, drizzle and virga. In this paper, lidar measurements of the median volume raindrop diameter and rain evaporation rate profiles are compared with a model analytical solution. The intercomparison reveals good agreement between the model and observations, with a correlation between the profiles up to 65% and a root-mean-square error up to 22% with a 5% bias. Larger discrepancies are due to radiosonde soundings different air masses and model assumptions no more valid along the profile as nonsteady atmosphere and/or appearance of collision–coalescence processes. Nevertheless, this study shares valuable information to better characterize the rain evaporation processes

    Assembly and Certification of ATLAS Muon Stations for the Middle and Outer Barrel at CERN

    Get PDF
    Roughly 400 of the approximately 700 muon stations of the ATLAS barrel belong to the middle and outer layer. Barrel Middle and Barrel Outer stations consist of both an MDT chamber and one or two RPC planes delivering the level-1 trigger information. While MDT chambers and individual RPC units are constructed at their home institutes, the assembly of the RPCs into planes, including the final cabling and the mounting of the trigger electronics, as well as the integration of MDTs and RPCs into muon stations takes place at CERN. MDT chambers, RPC planes and the completed stations have to pass a series of tests before being declared 'ready-for-installation'. Final certification criteria is the passing of a one-day cosmic ray test, for which a special setup has been built in building 899 (BB5). This note gives an overview over the work carried out in BB5, with emphasis on the cosmic ray test. Examples of abnormal chamber behavior will be discussed and a summary of common mistakes in station assembly or chamber cabling will be given. A second focus of the note is on the statistical analysis of the certification results
    • …
    corecore