90 research outputs found

    The Effect of Unenhanced MRI on the Surgeons' Decision-Making Process in Females with Suspected Appendicitis

    Get PDF
    This prospective study evaluated the impact of the results of unenhanced magnetic resonance imaging (MRI) on the surgeon's diagnosis of acute appendicitis in potentially fertile females. 112 female patients, aged 12-55, with suspected appendicitis underwent MRI of the abdomen. At three defined intervals; admission and clinical re-evaluation before and after revealing the MRI results, the surgeon recorded the attendance of each patient in operative treatment, observation or discharge. Appendicitis was confirmed or declined by pathology or by telephone follow-up in case of non-intervention. Appendicitis was confirmed in 29 of 112 patients. At admission the surgeon's disposition had a sensitivity of 97 % and specificity of 29 %. After knowing the MRI results, sensitivity was 97 % and specificity 64 %. The sensitivity and specificity of MRI alone were 89 and 100 %, with a negative and positive predictive value of 96 and 100 %, respectively. We believe that MRI should perhaps be standard in all female patients during their reproductive years with suspected appendicitis. It avoids an operation in 32 % of cases and allows earlier planning for patients with an equivocal clinical picture. Trial number: OND1292733 (Narcis.nl)

    Does Centralization of Radical Prostatectomy Reduce the Incidence of Postoperative Urinary Incontinence?

    Get PDF
    Background: On the basis of previous analyses of the incidence of urinary incontinence (UI) after radical prostatectomy (RP), the hospital RP volume threshold in the Netherlands was gradually increased from 20 per year in 2017, to 50 in 2018 and 100 from 2019 onwards. Objective: To evaluate the impact of hospital RP volumes on the incidence and risk of UI after RP (RP-UI). Design, setting, and participants: Patients who underwent RP during 2016–2020 were identified in the claims database of the largest health insurance company in the Netherlands. Incontinence was defined as an insurance claim for ≥1 pads/d. Outcome measurements and statistical analysis: The relationship between hospital RP volume (HV) and RP-UI was assessed via multivariable analysis adjusted for age, comorbidity, postoperative radiotherapy, and lymph node dissection. Results and limitations: RP-UI incidence nationwide and by RP volume category did not decrease significantly during the study period, and 5-yr RP-UI rates varied greatly among hospitals (19–85%). However, low-volume hospitals (≤120 RPs/yr) had a higher percentage of patients with RP-UI and higher variation in comparison to high-volume hospitals (&gt;120 RPs/yr). In comparison to hospitals with low RP volumes throughout the study period, the risk of RP-UI was 29% lower in hospitals shifting from the low-volume to the high-volume category (&gt;120 RPs/yr) and 52% lower in hospitals with a high RP volume throughout the study period (&gt;120 RPs/yr for 5 yr). Conclusions: A focus on increasing hospital RP volumes alone does not seem to be sufficient to reduce the incidence of RP-UI, at least in the short term. Measurement of outcomes, preferably per surgeon, and the introduction of quality assurance programs are recommended. Patient summary: In the Netherlands, centralization of surgery to remove the prostate (RP) because of cancer has not yet improved the occurrence of urinary incontinence (UI) after surgery. Hospitals performing more than 120 RP operations per year had better UI outcomes. However, there was a big difference in UI outcomes between hospitals.</p

    Procedural Performance of Ultrathin, Biodegradable Polymer-Coated Stents Versus Durable Polymer-Coated Stents Based on Intracoronary Imaging

    Get PDF
    OBJECTIVE: Thinner stent struts might lead to a higher risk of recoil and subsequently a smaller minimal stent area (MSA), which is known to be the strongest predictor of stent failure. We compared procedural performance between an ultrathin-strut biodegradable-polymer sirolimus-eluting stent (BP-SES) and a durable-polymer zotarolimus-eluting stent (DP-ZES) using intracoronary imaging.METHODS: A consecutive cohort of patients underwent percutaneous coronary intervention (PCI) with either BP-SES or DP-ZES in a pseudorandomized fashion between July 2018 and October 2019. In the present subanalysis, we included cases in which post-PCI imaging with intravascular ultrasound (IVUS) or optical coherence tomography (OCT) was performed. The primary endpoint of the study was MSA. Secondary endpoints included percentage stent expansion and presence of residual edge disease, malapposition, tissue protrusion, submedial edge dissections, or edge hematoma.RESULTS: A total of 141 treated lesions (78 BP-SES and 63 DP-ZES) in 127 patients were analyzed. Median age was 69.3 years (interquartile range [IQR], 57.3-75.6) and 74.0% of patients were male. All baseline and procedural characteristics were comparable between both groups. Median MSA was 5.80 mm² (IQR, 4.40-7.24) for BP-SES and 6.35 mm² (IQR, 4.76-8.31) for DP-ZES (P=.15). No significant differences in stent expansion, residual edge disease and presence of malapposition, tissue protrusion, submedial edge dissections, or edge hematomas were found. Stent diameter and stent length were found to be independent predictors of MSA.CONCLUSIONS: No significant differences in MSA were found between lesions treated with BP-SES vs DP-ZES. BP-SES and DP-ZES were comparable in terms of procedural performance.</p

    Procedural Performance of Ultrathin, Biodegradable Polymer-Coated Stents Versus Durable Polymer-Coated Stents Based on Intracoronary Imaging

    Get PDF
    OBJECTIVE: Thinner stent struts might lead to a higher risk of recoil and subsequently a smaller minimal stent area (MSA), which is known to be the strongest predictor of stent failure. We compared procedural performance between an ultrathin-strut biodegradable-polymer sirolimus-eluting stent (BP-SES) and a durable-polymer zotarolimus-eluting stent (DP-ZES) using intracoronary imaging.METHODS: A consecutive cohort of patients underwent percutaneous coronary intervention (PCI) with either BP-SES or DP-ZES in a pseudorandomized fashion between July 2018 and October 2019. In the present subanalysis, we included cases in which post-PCI imaging with intravascular ultrasound (IVUS) or optical coherence tomography (OCT) was performed. The primary endpoint of the study was MSA. Secondary endpoints included percentage stent expansion and presence of residual edge disease, malapposition, tissue protrusion, submedial edge dissections, or edge hematoma.RESULTS: A total of 141 treated lesions (78 BP-SES and 63 DP-ZES) in 127 patients were analyzed. Median age was 69.3 years (interquartile range [IQR], 57.3-75.6) and 74.0% of patients were male. All baseline and procedural characteristics were comparable between both groups. Median MSA was 5.80 mm² (IQR, 4.40-7.24) for BP-SES and 6.35 mm² (IQR, 4.76-8.31) for DP-ZES (P=.15). No significant differences in stent expansion, residual edge disease and presence of malapposition, tissue protrusion, submedial edge dissections, or edge hematomas were found. Stent diameter and stent length were found to be independent predictors of MSA.CONCLUSIONS: No significant differences in MSA were found between lesions treated with BP-SES vs DP-ZES. BP-SES and DP-ZES were comparable in terms of procedural performance.</p

    Validation of Claims Data for Absorbing Pads as a Measure for Urinary Incontinence after Radical Prostatectomy, a National Cross-Sectional Analysis

    Get PDF
    The use of healthcare insurance claims data for urinary incontinence (UI) pads has the potential to serve as an objective measure for assessing post-radical prostatectomy UI rates, but its validity for this purpose has not been established. The aim of this study is to correlate claims data with Patient Reported Outcome Measures (PROMs) for UI pad use. Patients who underwent RP in the Netherlands between September 2019 and February 2020 were included. Incontinence was defined as the daily use of ≥1 pad(s). Claims data for UI pads at 12-15 months after RP were extracted from a nationwide healthcare insurance database in the Netherlands. Participating hospitals provided PROMS data. In total, 1624 patients underwent RP. Corresponding data of 845 patients was provided by nine participating hospitals, of which 416 patients were matched with complete PROMs data. Claims data and PROMs showed 31% and 45% post-RP UI (≥1 pads). UI according to claims data compared with PROMs had a sensitivity of 62%, specificity of 96%, PPV of 92%, NPV of 75% and accuracy of 81%. The agreement between both methods was moderate (κ = 0.60). Claims data for pads moderately align with PROMs in assessing post-prostatectomy urinary incontinence and could be considered as a conservative quality indicator.</p

    Belonging from the Start: Proactive Techniques For Fostering Comfort in the Library Setting

    No full text
    Approaching the library for research help for the first time can sometimes be an intimidating prospect for our students — even more so for those from marginalized communities or those struggling with a sense of belonging on our campus. This presentation details ways Roesch Library\u27s librarians attempt to extend a welcoming atmosphere of belonging to all students, primarily in the time before they even set foot into an office or classroom with one of us
    • …
    corecore