343 research outputs found

    Land selection and management in Alaskan municipalities

    Get PDF

    Testing the single-pass VOC removal efficiency of an active green wall using methyl ethyl ketone (MEK)

    Full text link
    © 2017, The Author(s). In recent years, research into the efficacy of indoor air biofiltration mechanisms, notably living green walls, has become more prevalent. Whilst green walls are often utilised within the built environment for their biophilic effects, there is little evidence demonstrating the efficacy of active green wall biofiltration for the removal of volatile organic compounds (VOCs) at concentrations found within an interior environment. The current work describes a novel approach to quantifying the VOC removal effectiveness by an active living green wall, which uses a mechanical system to force air through the substrate and plant foliage. After developing a single-pass efficiency protocol to understand the immediate effects of the system, the active green wall was installed into a 30-m3 chamber representative of a single room and presented with the contaminant 2-butanone (methyl ethyl ketone; MEK), a VOC commonly found in interior environments through its use in textile and plastic manufacture. Chamber inlet levels of MEK remained steady at 33.91 ± 0.541 ppbv. Utilising a forced-air system to draw the contaminated air through a green wall based on a soil-less growing medium containing activated carbon, the combined effects of substrate media and botanical component within the biofiltration system showed statistically significant VOC reduction, averaging 57% single-pass removal efficiency over multiple test procedures. These results indicate a high level of VOC removal efficiency for the active green wall biofilter tested and provide evidence that active biofiltration may aid in reducing exposure to VOCs in the indoor environment

    Transmissivity of solar radiation within a Picea sitchensis stand under various sky conditions

    Get PDF
    We tested the hypothesis that diffuse radiation from cloudy and overcast skies penetrates the canopy more effectively than direct radiation from clear skies. We compared the flux density and spectral properties of direct and diffuse radiation (around solar noon (+/-1 h)) above, within and below a forest stand under sunny, cloudy and overcast conditions in a thinned Sitka spruce (Picea sitchensis (Bong.) Carr.) forest (28 years old, with a leaf area index of approximately 5.2m(2) m(-2)). We recorded vertical profiles of radiation penetration (from 350 to 1050 nm), and we also explored the horizontal pattern of radiation along a 115m transect. We showed that in "clear sky" conditions, the photosynthetically active radiation in the lower parts of the canopy was substantially attenuated, more so than under cloudy and overcast skies. It was particularly depleted in the blue part of the spectrum, but only slightly blue-depleted when the sky was overcast or cloudy. Moreover, the red : far-red ratio under clear skies fell to values less than 0.3 but only to 0.6 under cloudy or overcast skies. Near the ground, the light climate was strongly influenced by the thinning pattern (carried out in accordance with standard forestry management practice).Peer reviewe

    Improvement of Indoor Air Quality by MDF panels containing walnut shells

    Get PDF
    High levels of Volatile Organic Compounds (VOCs) and extremes of Relative Humidity (RH) commonly reduce indoor air quality with associated negative effects on human health and wellbeing. Interior materials are known to be one of the main contributors to poor indoor air quality. Notwithstanding, they can also act as a sink for airborne pollutants and excess moisture through adsorption. In this paper, we evaluate the ability of Medium Density Fibreboard (MDF) modified with walnut shell to regulate RH, toluene, limonene, dodecane and formaldehyde. The physicochemical properties, including molecular size/shape, vapour pressure, polarity and boiling point of VOCs allowed them to represent a range of pollutants. Adsorption and desorption behaviour of MDF containing up to 15% walnut shell was evaluated in 2-L environmental chambers under dynamic conditions at 23 °C and 50% RH. The porous microstructure of the MDF and walnut shell and their chemical composition were analysed using SEM, XRD and FTIR. Compared to a control panel, walnut shell additions showed an improved ability to remove VOCs and formaldehyde from the indoor air and buffer humidity. Of particular significance was the irreversible sink effect of formaldehyde and dodecane. This was attributed to the porous surface of walnut shell increasing the specific surface area of the panel and thus its adsorption capacity. The improved capacity of buffer humidity also increased the ability to adsorb water soluble VOCs such as formaldehyde. This research provides for the first time significant evidence that walnut shell modified MDF can improve indoor air quality

    Noninvasive measurements of arterial stiffness: Repeatability and interrelationships with endothelial function and arterial morphology measures

    Get PDF
    Corey J Huck1, Ulf G Bronas1, Eric B Williamson1, Christopher C Draheim1, Daniel A Duprez2, Donald R Dengel1,31School of Kinesiology, University of Minnesota, Minneapolis, MN, USA; 2Cardiovascular Division, Department of Medicine, University of Minnesota, Minneapolis, MN; 3Research Service, Minneapolis Veterans Affairs Medical Center, Minneapolis, MN, USABackground: Many noninvasive arterial assessment techniques have been developed, measuring different parameters of arterial stiffness and endothelial function. However, there is little data available comparing different devices within the same subject. Therefore, the purpose of this study was to examine the repeatability and interrelationships between 3 different techniques to measure arterial stiffness and to compare this with forearm-mediated dilation.Methods: Carotid-radial pulse wave velocity was measured by the Sphygmocor (SPWV) and Complior (CPWV) devices, cardio-ankle vascular index (CAVI) was measured by the VaSera device, vascular structure and function was assessed using ultrasonography and evaluated for reliability and compared in 20 apparently healthy, college-aged men and women.Results: The intraclass correlation coefficient and standard error of the mean for the Sphygmocor (R = 0.56, SEM = 0.69), Complior (R = 0.62, SEM = 0.69), and VaSera (R = 0.60, SEM = 0.56), indicated moderate repeatability. Bland-Altman plots indicated a mean difference of 0.11 ± 0.84 for SPWV, 0.13 ± 1.15 for CPWV, and –0.43 ± 0.90 for CAVI. No significant interrelationships were found among the ultrasound measures and SPWV, CPWV, and CAVI.Conclusions: The three noninvasive modalities to study arterial stiffness reliably measures arterial stiffness however, they do not correlate with ultrasound measures of vascular function and structure in young and apparently healthy subjects.Keywords: Pulse wave velocity, intima-media thickness, flow-mediated dilatio

    Lateral magnetic anisotropy superlattice out of a single (Ga,Mn)As layer

    Full text link
    We use lithographically induced strain relaxation to periodically modulate the magnetic anisotropy in a single (Ga,Mn)As layer. This results in a lateral magnetoresistance device where two non-volatile magnetic states exist at zero external magnetic field with resistances resulting from the orientation of two lithographically defined regions in a single and contiguous layer.Comment: 5 pages, 7 figure

    Submaximal Oxygen Uptake Kinetics, Functional Mobility, and Physical Activity in Older Adults with Heart Failure and Reduced Ejection Fraction

    Get PDF
    Background: Submaximal oxygen uptake measures are more feasible and may better predict clinical cardiac outcomes than maximal tests in older adults with heart failure (HF). We examined relationships between maximal oxygen uptake, submaximal oxygen kinetics, functional mobility, and physical activity in older adults with HF and reduced ejection fraction. Methods: Older adults with HF and reduced ejection fraction (n = 25, age 75 ± 7 years) were compared to 25 healthy age- and gender-matched controls. Assessments included a maximal treadmill test for peak oxygen uptake (VO2peak), oxygen uptake kinetics at onset of and on recovery from a submaximal treadmill test, functional mobility testing [Get Up and Go (GUG), Comfortable Gait Speed (CGS), Unipedal Stance (US)], and self-reported physical activity (PA). Results: Compared to controls, HF had worse performance on GUG, CGS, and US, greater delays in submaximal oxygen uptake kinetics, and lower PA. In controls, VO2peak was more strongly associated with functional mobility and PA than submaximal oxygen uptake kinetics. In HF patients, submaximal oxygen uptake kinetics were similarly associated with GUG and CGS as VO2peak, but weakly associated with PA. Conclusions: Based on their mobility performance, older HF patients with reduced ejection fraction are at risk for adverse functional outcomes. In this population, submaximal oxygen uptake measures may be equivalent to VO2 peak in predicting functional mobility, and in addition to being more feasible, may provide better insight into how aerobic function relates to mobility in older adults with HF

    Next big challenges in core AI technology

    Get PDF
    Algorithms and the Foundations of Software technolog
    • …
    corecore