74 research outputs found
Pull-out and push-in tests of bonded steel strands
MartĂ Vargas, JR. (2013). Pull-out and push-in tests of bonded steel strands. Magazine of Concrete Research. 65(18):1128-1131. doi:10.1680/macr.13.00061S112811316518BalĂĄzs LG .Bond Model with Non-Linear Bond-Slip Law, 1987, Politecnico di Milano, Italy, 395â430, Studi e Ricerche, Post-Graduate Course for Reinforced Concrete Structures, V.8/86.Balazs, G. L. (1992). Transfer Control of Prestressing Strands. PCI Journal, 37(6), 60-71. doi:10.15554/pcij.11011992.60.71Balazs, G. L. (1993). Transfer Length of Prestressing Strand as a Function of Draw-In and Initial Prestress. PCI Journal, 38(2), 86-93. doi:10.15554/pcij.03011993.86.93BalĂĄzs, G. L. (2007). Connecting Reinforcement to Concrete by Bond. Beton- und Stahlbetonbau, 102(S1), 46-50. doi:10.1002/best.200710109Carmo RNF .Ancoragem de Armaduras PrĂ©-Esforçadas por PrĂ©-TensĂŁo. MSc thesis, 1999, Faculdade de CiĂȘncias e Tecnologia, Universidade de Coimbra, Portugal, (in Portuguese).Faria, D. M. V., LĂșcio, V. J. G., & Pinho Ramos, A. (2011). Pull-out and push-in tests of bonded steel strands. Magazine of Concrete Research, 63(9), 689-705. doi:10.1680/macr.2011.63.9.689Faria, D. M. V., LĂșcio, V. J. G., & Ramos, A. P. (2011). Strengthening of flat slabs with post-tensioning using anchorages by bonding. Engineering Structures, 33(6), 2025-2043. doi:10.1016/j.engstruct.2011.02.039Faria, D. M. V., LĂșcio, V. J. G., & Pinho Ramos, A. (2012). Post-punching behaviour of flat slabs strengthened with a new technique using post-tensioning. Engineering Structures, 40, 383-397. doi:10.1016/j.engstruct.2012.03.014Laldji S .Bond Characteristics of Prestressing Strand in Grout. MPhil thesis, 1987, University of Leicester, UK.Laldji, S., & Young, A. G. (1988). Bond between steel strand and cement grout in ground anchorages. Magazine of Concrete Research, 40(143), 90-98. doi:10.1680/macr.1988.40.143.90Lopes, S. M. R., & do Carmo, R. N. F. (2002). Bond of prestressed strands to concrete: transfer rate and relationship between transmission length and tendon draw-in. Structural Concrete, 3(3), 117-126. doi:10.1680/stco.2002.3.3.117MartĂ-Vargas, J. R., Serna-Ros, P., FernĂĄndez-Prada, M. A., Miguel-Sosa, P. F., & ArbelĂĄez, C. A. (2006). Test method for determination of the transmission and anchorage lengths in prestressed reinforcement. Magazine of Concrete Research, 58(1), 21-29. doi:10.1680/macr.2006.58.1.21Marti-Vargas, J. R., Arbelaez, C. A., Serna-Ros, P., Navarro-Gregori, J., & Pallares-Rubio, L. (2007). Analytical model for transfer length prediction of 13 mm prestressing strand. Structural Engineering and Mechanics, 26(2), 211-229. doi:10.12989/sem.2007.26.2.211Palmer, K. D., & Schultz, A. E. (2011). Experimental investigation of the web-shear strength of deep hollow-core units. PCI Journal, 56(4), 83-104. doi:10.15554/pcij.09012011.83.10
Mobile app-based symptom-rhythm correlation assessment in patients with persistent atrial fibrillation
Background: The assessment of symptom-rhythm correlation (SRC) in patients with persistent atrial fibrillation (AF) is challenging. Therefore, we performed a novel mobile app-based approach to assess SRC in persistent AF.Methods: Consecutive persistent AF patients planned for electrical cardioversion (ECV) used a mobile app to record a 60-s photoplethysmogram (PPG) and report symptoms once daily and in case of symptoms for four weeks prior and three weeks after ECV. Within each patient, SRC was quantified by the SRC-index defined as the sum of symptomatic AF recordings and asymptomatic non-AF recordings divided by the sum of all recordings.Results: Of 88 patients (33% women, age 68 +/- 9 years) included, 78% reported any symptoms during recordings. The overall SRC-index was 0.61 (0.44-0.79). The study population was divided into SRC-index tertiles: low (= 0.73). Patients within the low (vs high) SRC-index tertile had more often heart failure and diabetes mellitus (both 24.1% vs 6.9%). Extrasystoles occurred in 19% of all symptomatic non-AF PPG recordings. Within each patient, PPG recordings with the highest (vs lowest) tertile of pulse rates conferred an increased risk for symptomatic AF recordings (odds ratio [OR] 1.26, 95% coincidence interval [CI] 1.04-1.52) and symptomatic non-AF recordings (OR 2.93, 95% CI 2.16-3.97). Pulse variability was not associated with reported symptoms.Conclusions: In patients with persistent AF, SRC is relatively low. Pulse rate is the main determinant of reported symptoms. Further studies are required to verify whether integrating mobile app-based SRC assessment in current workflows can improve AF management
Selective ETA vs. Dual ETA/B receptor blockade for the prevention of sunitinib-induced hypertension and albuminuria in WKY rats
Aims Although effective in preventing tumour growth, angiogenesis inhibitors cause off-target effects including cardiovascular toxicity and renal injury, most likely via endothelin (ET)-1 up-regulation. ET-1 via stimulation of the ETA receptor has pro-hypertensive actions whereas stimulation of the ETB receptor can elicit both pro-or antihypertensive effects. In this study, our aim was to determine the efficacy of selective ETA vs. dual ETA/B receptor blockade for the prevention of angiogenesis inhibitor-induced hypertension and albuminuria. Methods and results Male Wistar Kyoto (WKY) rats were treated with vehicle, sunitinib (angiogenesis inhibitor; 14 mg/kg/day) alone or in combination with macitentan (ETA/B receptor antagonist; 30 mg/kg/day) or sitaxentan (selective ETA receptor antagonist; 30 or 100 mg/kg/day) for 8 days. Compared with vehicle, sunitinib treatment caused a rapid and sustained increase in mean arterial pressure of-25 mmHg. Co-treatment with macitentan or sitaxentan abolished the pressor response to sunitinib. Sunitinib did not induce endothelial dysfunction. However, it was associated with increased aortic, mesenteric, and renal oxidative stress, an effect that was absent in mesenteric arteries of the macitentan and sitaxentan co-treated groups. Albuminuria was greater in the sunitinib-than vehicle-treated group. Co-treatment with sitaxentan, but not macitentan, prevented this increase in albuminuria. Sunitinib treatment increased circulating and urinary prostacyclin levels and had no effect on thromboxane levels. These increases in prostacyclin were blunted by co-treatment with sitaxentan. Conclusions Our results demonstrate that both selective ETA and dual ETA/B receptor antagonism prevents sunitinib-induced hypertension, whereas sunitinib-induced albuminuria was only prevented by selective ETA receptor antagonism. In addition, our results uncover a role for prostacyclin in the development of these effects. In conclusion, selective ETA receptor antagonism is sufficient for the prevention of sunitinib-induced hypertension and renal injury
Characterization of Loading Responses and Failure Loci of a Boron Steel Spot Weld
Boron steel, classed as an ultra high-strength steel (UHSS), has been utilized in anti-intrusion systems in automobiles, providing high strength and weight-saving potential through gage reduction. UHSS spot welds exhibit unique hardness distributions, with a hard nugget and outlying base material, but with a soft heat-affected zone in-between these regions. This soft zone reduces the strength of the weld and makes it susceptible to failure. Due to the interaction of various weld zones that occurs during loading, there is a need to characterize the loading response of the weld for accurate failure predictions. The loading response of certain weld zones, as well as failure loci, was obtained through physical simulation of the welding process. The results showed a significant difference in mechanical behavior through the weld length. An important result is that instrumented indentation was shown to be a valid, quantitative method for verifying the accuracy with which weld microstructure has been recreated with regard to the target weld microstructure
Effect of Weld Schedule on the Residual Stress Distribution of Boron Steel Spot Welds
Press-hardened boron steel has been utilized in anti-intrusion systems in automobiles, providing high strength and weight-saving potential through gage reduction. Boron steel spot welds exhibit a soft heat-affected zone which is surrounded by a hard nugget and outlying base material. This soft zone reduces the strength of the weld and makes it susceptible to failure. Additionally, different welding regimes lead to significantly different hardness distributions, making failure prediction difficult. Boron steel sheets, welded with fixed and adaptive schedules, were characterized. These are the first experimentally determined residual stress distributions for boron steel resistance spot welds which have been reported. Residual strains were measured using neutron diffraction, and the hardness distributions were measured on the same welds. Additionally, similar measurements were performed on spot welded DP600 steel as a reference material. A correspondence between residual stress and hardness profiles was observed for all welds. A significant difference in material properties was observed between the fixed schedule and adaptively welded boron steel samples, which could potentially lead to a difference in failure loads between the two boron steel welds
Shear capacity of 50 years old reinforced concrete bridge deck without shear reinforcement
A relatively low direct tensile strength is observed in cores drilled from old bridges in the Netherlands. To check whether this will influence the shear capacity of the bridges, beams sawn from a bridge deck built in 1961 were tested under shear loading in the Stevin laboratory at TU Delft. The flexural capacity of the beams was increased by means of carbon laminates glued to the bottom side. New beams with the same concrete compressive strength and reinforcement arrangement were casted and tested as reference. Six tests on old concrete beams and six tests on new concrete beams with a shear slenderness ratio between 2.2 to 4.1, and a cube compressive strength of about 80 MPa have been performed. In these tests no difference was found between the shear capacity of old and new beams with the same compressive strength, although the lower direct tensile strength of the old concrete compared to the new concrete
NONLINEAR FINITE ELEMENT ANALYSES OF REINFORCED CONCRETE SLABS: COMPARISON OF SAFETY FORMATS
According to the new fib Model Code 2010 the design shear resistance of a reinforced
concrete (RC) structure can be evaluated through analytical and numerical calculation methods that
fall into four different levels of approximations; the complexity and the accuracy of the calculated
shear resistance increases with increasing the level of approximation. Nonlinear finite element
(NLFE) analyses belong to the highest level of approximation (Level IV) thanks to their advantage
to take into account real material properties and âhiddenâ capacities of the structure. Nevertheless,
even if NLFE analyses are more and more becoming an usual instrument in the daily design
process, building codes do not provide specific guidance on how to perform these analyses and if
appropriate checks are not done on the model used, a big scatter in the results obtained can be
detected. For this reason the Dutch Ministry of Transport, Public Works and Water Management is
running a project to re-evaluate the carrying capacity of existing bridges and viaducts (e.g.
reinforced and prestressed concrete beams and slabs) through NLFE analyses and published in a
document containing guidelines for nonlinear finite element analyses to be followed by users in
order to reduce model and users factors. In the paper several reinforced concrete slabs have been
analyzed through analytical and numerical procedures according to the Model Code 2010
prescriptions and following the Dutch guidelines. The analytical and numerical results obtained
have been compared with experimental results.
Parametric studies have also been carried out on the slabs in order to focus on the main sensitive
parameters that influence the results obtained from numerical simulations and in order to obtain
reliable and, at the same time, safe results. The main indications of the guidelines for reinforced
concrete slabs are presented in the paper
- âŠ