197 research outputs found

    Gold(i)/Zn(ii) catalyzed tandem hydroamination/annulation reaction of 4-yne-nitriles

    Get PDF
    The tandem hydroamination-annulation reaction of 4-pentyne-nitriles in the presence of amine nucleophiles and a cooperatively operating catalyst system, consisting of Ph3PAuCl and Zn(ClO4)2, provides an efficient route to 2-aminopyrroles. Two regioisomeric 2-aminopyrroles were formed in moderate to good yields. © 2010 The Royal Society of Chemistry.TÜBİTAK; TÜBA and MET

    Oligonucleotide Delivery Systems for Camptothecins

    Get PDF
    Camptothecin drugs are stabilized in their antitumor active lactone form by complexation with an oligonucleotide including RNA or catalytic RNA. The oligonucleotide-camptothecin drug complex may be incorporated within a macromolecular assembly including both viral and non-viral oligonucleotide vectors. The invention allows combination gene and camptothecin drug therapy

    The evaluation of doxorubicin-induced cardiotoxicity: Comparison of Doppler and tissue Doppler-derived myocardial performance index

    Get PDF
    Background: Doxorubicin is a chemotherapeutic agent used in a wide spectrum of cancers. However, cardiotoxic effects have limited its clinical use. The early detection of doxorubicin-induced cardiotoxicity is crucial. The purpose of our study was to assess values of Doppler and tissue Doppler imaging (TDI)-derived myocardial performance index (MPI) in adult cancer patients receiving doxorubicin treatment. Methods: A total of 45 patients underwent echocardiographic examinations before any doxorubicin had been administered and then after doxorubicin. Doppler and TDI-derived MPI of left ventricular (LV) were determined in the evaluation of cardiotoxicity. Additionally, TDI-derived MPI of right ventricular (RV) was determined. Results: All patients underwent control echocardiographic examination after mean 5 ± 1.7 months. The LV MPI obtained by both Doppler and TDI were increased after doxorubicin treatment (0.56 ± 0.11, 0.61 ± 0.10, p = 0,005 vs 0.51 ± 0.09, 0.59 ± 0.09, p = 0.001, respectively). There was no correlation between Doppler-derived MPI and cumulative doxorubicin dose (coefficient of correlation 0.11, p = 0.6). TDI-derived MPI was correlated with cumulative doxorubicin dose (coefficient of correlation 0.35, p = 0.015), but this correlation is weak (r = 0.38). The study population was divided into two groups according to doxorubicin dose (below and above 300 mg level). There was a moderate correlation between TDI-derived MPI and less than 300 mg of doxorubicin dose (coefficient of correlation 0.51, p = 0.028). However, Doppler-derived MPI was not correlated with less than 300 mg of doxorubicin dose (coefficient of correlation 0.38, p = 0.123). Also, there was no significant change in the TDI-derived RV-MPI (0.49 ± 0.14, 0.50 ± 0.12, p = 0.56). Conclusions: TDI-derived MPI is a useful parameter and an early indicator compared with Doppler-derived MPI in the detection of cardiotoxicity during the early stages. Also, doxorubicin administration does not affect RV function

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented

    Real-world efficacy and safety of Ledipasvir plus Sofosbuvir and Ombitasvir/Paritaprevir/Ritonavir +/- Dasabuvir combination therapies for chronic hepatitis C: A Turkish experience

    Get PDF
    Background/Aims: This study aimed to evaluate the real-life efficacy and tolerability of direct-acting antiviral treatments for patients with chronic hepatitis C (CHC) with/without cirrhosis in the Turkish population.Material and Methods: A total of 4,352 patients with CHC from 36 different institutions in Turkey were enrolled. They received ledipasvir (LDV) and sofosbuvir (SOF)+/- ribavirin (RBV) ombitasvir/paritaprevir/ritonavir +/- dasabuvir (PrOD)+/- RBV for 12 or 24 weeks. Sustained virologic response (SVR) rates, factors affecting SVR, safety profile, and hepatocellular cancer (HCC) occurrence were analyzed.Results: SVR12 was achieved in 92.8% of the patients (4,040/4,352) according to intention-to-treat and in 98.3% of the patients (4,040/4,108) according to per-protocol analysis. The SVR12 rates were similar between the treatment regimens (97.2%-100%) and genotypes (95.6%-100%). Patients achieving SVR showed a significant decrease in the mean serum alanine transaminase (ALT) levels (50.90 +/- 54.60 U/L to 17.00 +/- 14.50 U/L) and model for end-stage liver disease (MELD) scores (7.51 +/- 4.54 to 7.32 +/- 3.40) (p<0.05). Of the patients, 2 were diagnosed with HCC during the treatment and 14 were diagnosed with HCC 37.0 +/- 16.0 weeks post-treatment. Higher initial MELD score (odds ratio [OR]: 1.92, 95% confidence interval [CI]: 1.22-2.38; p=0.023]), higher hepatitis C virus (HCV) RNA levels (OR: 1.44, 95% CI: 1.31-2.28; p=0.038), and higher serum ALT levels (OR: 1.38, 95% CI: 1.21-1.83; p=0.042) were associated with poor SVR12. The most common adverse events were fatigue (12.6%), pruritis (7.3%), increased serum ALT (4.7%) and bilirubin (3.8%) levels, and anemia (3.1%).Conclusion: LDV/SOF or PrOD +/- RBV were effective and tolerable treatments for patients with CHC and with or without advanced liver disease before and after liver transplantation. Although HCV eradication improves the liver function, there is a risk of developing HCC.Turkish Association for the Study of The Liver (TASL

    Calibration of the CMS Drift Tube Chambers and Measurement of the Drift Velocity with Cosmic Rays

    Get PDF
    Peer reviewe

    CMS Data Processing Workflows during an Extended Cosmic Ray Run

    Get PDF
    Peer reviewe

    Commissioning and performance of the CMS silicon strip tracker with cosmic ray muons

    Get PDF
    This is the Pre-print version of the Article. The official published version of the Paper can be accessed from the link below - Copyright @ 2010 IOPDuring autumn 2008, the Silicon Strip Tracker was operated with the full CMS experiment in a comprehensive test, in the presence of the 3.8 T magnetic field produced by the CMS superconducting solenoid. Cosmic ray muons were detected in the muon chambers and used to trigger the readout of all CMS sub-detectors. About 15 million events with a muon in the tracker were collected. The efficiency of hit and track reconstruction were measured to be higher than 99% and consistent with expectations from Monte Carlo simulation. This article details the commissioning and performance of the Silicon Strip Tracker with cosmic ray muons.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)

    Alignment of the CMS silicon tracker during commissioning with cosmic rays

    Get PDF
    The CMS silicon tracker, consisting of 1440 silicon pixel and 15 148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions of the modules were determined with respect to cosmic ray trajectories to an average precision of 3-4 microns RMS in the barrel and 3-14 microns RMS in the endcap in the most sensitive coordinate. The results have been validated by several studies, including laser beam cross-checks, track fit self-consistency, track residuals in overlapping module regions, and track parameter resolution, and are compared with predictions obtained from simulation. Correlated systematic effects have been investigated. The track parameter resolutions obtained with this alignment are close to the design performance
    corecore