211 research outputs found
Evaluation of wound healing and postoperative pain after oral mucosa laser biopsy with the aid of compound with chlorhexidine and sodium hyaluronate: a randomized double blind clinical trial
OBJECTIVES:
The aim of this study is to evaluate secondary intention healing process and postoperative pain of oral soft tissues after laser surgery with the use of a compound containing chlorhexidine and sodium hyaluronate.
MATERIALS AND METHODS:
This double-blind, randomized clinical study included 56 patients affected by benign oral lesions and subjected to excisional biopsy with diode laser and randomly divided into three groups. Study group (SG) received 0.2% chlorhexidine digluconate and 0.2% sodium hyaluronate treatment; control group (CG) received 0.2% chlorhexidine digluconate; and placebo group (PG) followed the same protocol, taking a neutral solution having the same organoleptic characteristics. Wound healing was evaluated using percentage healing index (PHI). Numeric rating scale (NRS) was used to evaluate postoperative pain.
RESULTS:
PHI (T1 = 7 days) was 67.25% for SG, 58.67% for CG, and 54.55% for PG. PHI (T2 = 14 days) was 94.35% for SG, 77.79% for CG, and 78.98% for PG. A statistically significant difference was between the groups for PHI at T2 p = 0.001. No difference was detectable for pain index.
CONCLUSIONS:
A solution containing sodium hyaluronate and chlorhexidine is a good support to increase wound healing by secondary intention after laser biopsy, but no differences were in postoperative perception of pain.
CLINICAL RELEVANCE:
The use of the tested solution can be recommended after laser oral biopsies, to achieve a healing without suture. About the postoperative pain, the compound has not showed the same results and did not have measurable effects
Исследование в области химии производных карбазола
A biopsy is a surgical procedure performed to establish a clear diagnosis of a lesion in order to clarify a clinical diagnostic suspicion. During a biopsy procedure it is fundamental to maintain safe and readable cut margins in order to permit histological visualization of possible marginal infiltrations or malignant transformation of a lesion. The aim of this study was to evaluate the histological peripheral damage caused by application of a KTP (potassium titanium phosphate) laser during oral soft tissue biopsy procedures. A KTP laser (λ 532 nm) at different power settings and fluences was used to obtain 45 samples from pig cadaver tongues. The samples were then subdivided into five groups of nine samples each. A final specimen was taken by scalpel as a control. All samples were put into test tubes containing 10% buffered formalin solution, and were examined separately under an optical microscope by two pathologists to evaluate the peripheral thermal damage induced by the laser. In all specimens the cut edges of the incision were free from histological artefacts, especially when lower settings were applied. Statistical analysis showed no differences among the groups. The KTP laser demonstrated surgical effectiveness and caused little peripheral damage to the cut edges, and therefore would always allow a safe histological diagnosis to be obtained. © Springer-Verlag London Ltd 2010
Bone damage induced by different cutting instruments: an in vitro study
The aim of this study was to compare the peripheral bone damage induced by different cutting systems. Four devices were tested: Er:YAG laser (2.94 mm), Piezosurgery, high-speed drill and low-speed drill. Forty-five bone sections, divided into 9 groups according to different parameters, were taken from pig mandibles within 1 h post mortem. Specimens were fixed in 10% buffered formalin, decalcified and cut in thin sections. Four different parameters were analyzed: cut precision, depth of incision, peripheral carbonization and presence of bone fragments. For statistical analysis, the Kruskal-Wallis test was applied to assess equality of sample medians among groups. All sections obtained with the Er:YAG laser showed poor peripheral carbonization. The edges of the incisions were always well-shaped and regular, no melting was observed. Piezosurgery specimens revealed superficial incisions without thermal damage but with irregular edges. The sections obtained by traditional drilling showed poor peripheral carbonization, especially if obtained at lower speed. There was statistically significant differences (p<0.01) among the cutting systems for all analyzed parameters. Er:YAG laser, gave poor peripheral carbonization, and may be considered an effective method in oral bone biopsies and permits to obtain clear and readable tissue specimens
Laser photobiomodulation (PBM)-A possible new frontier for the treatment of oral cancer: a review of In vitro and in vivo studies
The treatment of oral squamous cell carcinoma (OSCC) is particularly complex due to its aggressive behavior, location, the patient's age, and its spread at diagnosis. In recent years, photobiomodulation (PBM) has been introduced in different medical fields; however, its application, in patients suffering from OSCC for palliative support or to induce analgesia, has been hotly debated due to the possibility that the cell growth stimuli induced by PBM could lead to a worsening of the lesions. The aim of this study is to review the literature to observe the available data investigating the effect of PBM on cancer cells in vitro and in vivo. A review was conducted on the PubMed and Scopus databases. A total of twelve studies met the inclusion criteria and were therefore included for quality assessment and data extraction. The analysis showed that the clinical use of PBM is still only partially understood and is, therefore, controversial. Some authors stated that it could be contraindicated for clinical use in patients suffering from SCC, while others noted that it could have beneficial effects. According to the data that emerged from this review, it is possible to hypothesize that there are possibilities for PBM to play a beneficial role in treating cancer patients, but further evidence about its clinical efficacy and the identification of protocols and correct dosages is still needed
Liquid biopsy in the assessment of microRNAs in oral squamous cell carcinoma : a systematic review
The identification of non-invasive biomarkers from biological fluids collected by liquid biopsy provides new horizons for individualized therapeutic strategies and improves clinical decision-making in OSCC patients. Circulating microRNAs have emerged as
Histological effects of an innovative 445 Nm Blue Laser during oral soft tissue biopsy.
Continuously evolving laser devices can be used in various fields; they are an alternative to the traditional cold blade surgery to perform biopsies of oral soft tissues. The aspect focused on in this paper is the possibility to use the 445 nm diode laser (Eltech K-Laser srl, Treviso, Italy) in complete safety, by evaluating its thermal effects during microscopy. A histological evaluation of the alteration of the peri-incisional edges on 10 samples was realized. All excisional biopsies were related to clinically unsuspected lesions and performed by the same expert operator. The surgical procedure was performed with the same laser parameters and the same pathologist evaluated the thermal effect on the samples. An average value of the detected tissue alteration was calculated; the average damage of the epithelium was 650.93 μm, while in the connective tissue it was 468.07 μm. In all the cases a clear diagnosis was possible, and no clinical complications were observed; so, the 445 nm diode laser proved to be a device that can be safely used for biopsies of clinically unsuspicious lesions. Due to the small number of cases, this in vivo preliminary experience needs to be extended
Effectiveness of KTP laser versus 980nm diode laser to kill Enterococcus faecalis in biofilms developed in experimentally infected root canals
This study aimed to evaluate the antibacterial action of KTP (potassium-titanyl-phosphate) laser irradiations (compared with 980nm diode laser), associated with conventional endodontic procedures, on Enterococcus faecalis biofilms. Fifty-six dental roots with single canals were prepared with Ni-Ti rotary instruments, autoclaved, inoculated with an E.faecalis suspension and incubated for 72h. They were randomly allocated to control and treatment groups. Laser parameters were as follows: power 2.5W, Ton 35ms, Toff 50ms (KTP laser); power 2.5W, Ton 30ms, Toff 30ms (980nm diode laser). To evaluate the residual bacterial load, BioTimer Assay was employed. The chemo-mechanical treatment together with laser irradiations (KTP and 980nm diode lasers) achieved a considerable reduction of bacterial load (higher than 96% and 93%, respectively). Regarding both laser systems, comparisons with conventional endodontic procedures (mortality rate of about 67%) revealed statistically highly significant differences (P≤0.01). This study confirms that laser systems can provide an additional aid in endodontic disinfection. © 2014 Australian Society of Endodontology
Photo-biomodulation as a prevention modality of oral mucositis in patients undergoing allogeneic hematopoietic stem cell transplantation
The aim of the study was to observe the eectiveness of a photo-biomodulation (PBM)
protocol for the prevention of oral mucositis (OM) in patients undergoing allogeneic hematopoietic
stem cell transplantation (aHSCT). A case-control study was conducted on 40 patients undergoing
aHSCT. The patients were divided into two groups; the preventive group (PG) included 20 patients
(7 females and 13 males) who were subjected to intra-oral PBM for five sessions a week, starting one
day before the conditioning regimen and continuing until the 10th day after transplantation (D+10).
In each session, ten points on the at-risk mucosal surfaces were irradiated using a double diode
laser that emits two wavelengths simultaneously at 650 nm and at 904–910 nm with the following
parameters at each point: energy of 4 J, and power of 88.9 mW. The control group (CG) included
20 patients (10 females and 10 males) who were not subjected to laser therapy and were selected
retrospectively to compare the obtained results. For all patients, OM was assessed by the World
Health Organization (WHO) grading scale. Eight patients in the PG did not experience OM during
their hospitalization period (with grade 0). Severe OM was observed in 40% of the patients in the
PG, while in the CG, severe OM was shown in 85% of the patients. The mean duration of OM in the
PG was significantly lower than that of CG (4.7 days in the PG and 15 days in the CG) (p < 0.001).
The study demonstrated that the preventive PBM protocol reduced the severity and duration of OM
in patients undergoing aHSCT
Heat treatment procedure of the Aluminium 6061-T651 for the Ariel Telescope mirrors
The Atmospheric Remote-Sensing Infrared Exoplanet Large Survey (Ariel) is the M4 mission adopted by ESA’s ”Cosmic Vision” program. Its launch is scheduled for 2029. The purpose of the mission is the study of exoplanetary atmospheres on a target of ∼ 1000 exoplanets. Ariel scientific payload consists of an off-axis, unobscured Cassegrain telescope. The light is directed towards a set of photometers and spectrometers with wavebands between 0.5 and 7.8 µm and operating at cryogenic temperatures. The Ariel Space Telescope consists of a primary parabolic mirror with an elliptical aperture of 1.1· 0.7 m, followed by a hyperbolic secondary, a parabolic collimating tertiary and a flat-folding mirror directing the output beam parallel to the optical bench; all in bare aluminium. The choice of bare aluminium for the realization of the mirrors is dictated by several factors: maximizing the heat exchange, reducing the costs of materials and technological advancement. To date, an aluminium mirror the size of Ariel’s primary has never been made. The greatest challenge is finding a heat treatment procedure that stabilizes the aluminium, particularly the Al6061T651 Laminated alloy. This paper describes the study and testing of the heat treatment procedure developed on aluminium samples of different sizes (from 50mm to 150mm diameter), on 0.7m diameter mirror, and discusses future steps
- …