8 research outputs found

    High-dose intensity-modulated radiotherapy for prostate cancer using daily fiducial marker-based position verification: acute and late toxicity in 331 patients

    Get PDF
    We evaluated the acute and late toxicity after high-dose intensity-modulated radiotherapy (IMRT) with fiducial marker-based position verification for prostate cancer. Between 2001 and 2004, 331 patients with prostate cancer received 76 Gy in 35 fractions using IMRT combined with fiducial marker-based position verification. The symptoms before treatment (pre-treatment) and weekly during treatment (acute toxicity) were scored using the Common Toxicity Criteria (CTC). The goal was to score late toxicity according to the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer (RTOG/EORTC) scale with a follow-up time of at least three years. Twenty-two percent of the patients experienced pre-treatment grade ≥ 2 genitourinary (GU) complaints and 2% experienced grade 2 gastrointestinal (GI) complaints. Acute grade 2 GU and GI toxicity occurred in 47% and 30%, respectively. Only 3% of the patients developed acute grade 3 GU and no grade ≥ 3 GI toxicity occurred. After a mean follow-up time of 47 months with a minimum of 31 months for all patients, the incidence of late grade 2 GU and GI toxicity was 21% and 9%, respectively. Grade ≥ 3 GU and GI toxicity rates were 4% and 1%, respectively, including one patient with a rectal fistula and one patient with a severe hemorrhagic cystitis (both grade 4). In conclusion, high-dose intensity-modulated radiotherapy with fiducial marker-based position verification is well tolerated. The low grade ≥ 3 toxicity allows further dose escalation if the same dose constraints for the organs at risk will be used

    Individualized 3D-printed applicators for magnetic resonance imaging-guided brachytherapy in nasal vestibule cancer

    Get PDF
    Background and purpose Brachytherapy is treatment of choice for early stage nasal vestibule cancer. Over the years improvements were achieved by means of image guided target definition, interstitial implant techniques and also individual mold techniques. The aim of this study was to improve the technique of the implant so that the need for interstitial catheters can be limited by making use of patient individualized 3D-printed applicators. Materials and Methods In 19 patients 3D-printed applicators were used to deliver pulse dose rate (PDR) brachytherapy. All patients underwent computed tomography (CT) and magnetic resonance imaging (MRI). A pre-plan with tumor delineation and manually optimized catheter positions to achieve tumor coverage was made. Based on the pre-plan a 3D-printed applicator was manufactured. Dose was evaluated by several indices: Conformity Index, Healthy Tissues Conformity Index, Dose Homogeneity Index, Dose non-uniformity ratio, Conformal index and high dose (HD) index. Results A high target coverage was achieved, with a median V100%CTV of 99.1 % (range, 81.8–100 %) and median CI of 0.99 (range, 0.82–1.00), as well as a median V0.7GyGTV of 100 % (range, 93.0–100 %). The median HD was 0.39 (range, 0.20–0.83). Interstitial catheters were needed in 12 patients. None of the patients developed grade ≥ II toxicity within the median follow up of 18 months. Conclusions This study shows that using 3D-printed applicators limits the need for interstitial catheters and also limits the high doses in normal tissue

    Long-term oncological follow-up after mold-based pulsed dose rate brachytherapy for early stage squamous cell carcinoma of the nasal vestibule: A single center experience of 68 patients over a 17-year period

    Get PDF
    PURPOSE: Cancer of the nasal vestibule is a rare type of malignancy constituting less than one percent of all head and neck cancers. These tumors are typically diagnosed at an early stage. Both surgery and radiotherapy provide excellent oncological results, but esthetic results are better after radiotherapy. The aim of this study was to evaluate the long-term oncological follow-up after brachytherapy for early stage squamous cell carcinoma of the nasal vestibule. METHODS AND MATERIALS: Retrospective analysis of patients with carcinoma of the nasal vestibule who were treated with primary brachytherapy in the Utrecht University Medical Center. RESULTS: In this single center experience over a 17-year period 68 patients with early stage squamous cell carcinoma of the nasal vestibule were treated with brachytherapy. Two patients had lymph node metastases at first clinical presentation. Median follow-up duration was 46.5 months. Five-year locoregional recurrence-free survival, disease-specific survival, and overall survival were 91.1%, 96.1%, and 66.2%, respectively. All recurrences occurred within the first 3 years of follow-up. CONCLUSIONS: Brachytherapy offers excellent oncological outcomes and is a safe and effective treatment for early stage carcinoma of the nasal vestibule. Recurrences typically occur within 3 years after treatment

    Optimal High-Dose-Rate Brachytherapy Fractionation Scheme After Keloid Excision: A Retrospective Multicenter Comparison of Recurrence Rates and Complications

    No full text
    Purpose: To determine the optimal brachytherapy dose and fractionation scheme for keloid treatment. Methods and Materials: Patient cohorts from 3 centers treated with keloid excision followed by 2 × 9 Gy, 3 × 6 Gy, or 2 × 6 Gy high-dose-rate brachytherapy were retrospectively compared regarding recurrence (after at least 12 months' follow-up) and complications (after at least 1 month's follow-up), using logistic regression analyses. Results: A total of 238 keloids were treated. An overall full recurrence rate of 8.3% was found. After correction for confounders (sex, skin color, keloid location, keloid duration) no statistically significant differences in recurrence rates could be discerned between fractionation schemes. There were 12.8% major and 45.6% minor complication rates. Lower radiation dose resulted in significantly fewer complications (odds ratio 0.35, P=.015). Conclusions: After excision of resistant keloids, high-dose-rate brachytherapy with a biological equivalent dose of approximately 20 Gy is recommended, on the basis of low recurrence and complication rates

    Comparison of megavoltage position verification for prostate irradiation based on bony anatomy and implanted fiducials

    No full text
    PURPOSE: The patient position during radiotherapy treatment of prostate cancer can be verified with the help of portal images acquired during treatment. In this study we quantify the clinical consequences of the use of image-based verification based on the bony anatomy and the prostate target itself. PATIENTS AND METHODS: We analysed 2025 portal images and 23 computed tomography (CT) scans from 23 patients with prostate cancer. In all patients gold markers were implanted prior to CT scanning. Statistical data for both random and systematic errors were calculated for displacements of bones and markers and we investigated the effectiveness of an off-line correction protocol. RESULTS: Standard deviations for systematic marker displacement are 2.4 mm in the lateral (LR) direction, 4.4 mm in the anterior-posterior (AP) direction and 3.7 mm in the caudal-cranial direction (CC). Application of off-line position verification based on the marker positions results in a shrinkage of the systematic error to well below 1 mm. Position verification based on the bony anatomy reduces the systematic target uncertainty to 50% in the AP direction and in the LR direction. No reduction was observed in the CC direction. For six out of 23 patients we found an increase of the systematic error after application of bony anatomy-based position verification. CONCLUSIONS: We show that even if correction based on the bony anatomy is applied, considerable margins have to be set to account for organ motion. Our study highlights that for individual patients the systematic error can increase after application of bony anatomy-based position verification, whereas the population standard deviation will decrease. Off-line target-based position verification effectively reduces the systematic error to well below 1 mm, thus enabling significant margin reductio

    High-dose intensity-modulated radiotherapy for prostate cancer using daily fiducial marker-based position verification: acute and late toxicity in 331 patients

    No full text
    Abstract We evaluated the acute and late toxicity after high-dose intensity-modulated radiotherapy (IMRT) with fiducial marker-based position verification for prostate cancer. Between 2001 and 2004, 331 patients with prostate cancer received 76 Gy in 35 fractions using IMRT combined with fiducial marker-based position verification. The symptoms before treatment (pre-treatment) and weekly during treatment (acute toxicity) were scored using the Common Toxicity Criteria (CTC). The goal was to score late toxicity according to the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer (RTOG/EORTC) scale with a follow-up time of at least three years. Twenty-two percent of the patients experienced pre-treatment grade ≥ 2 genitourinary (GU) complaints and 2% experienced grade 2 gastrointestinal (GI) complaints. Acute grade 2 GU and GI toxicity occurred in 47% and 30%, respectively. Only 3% of the patients developed acute grade 3 GU and no grade ≥ 3 GI toxicity occurred. After a mean follow-up time of 47 months with a minimum of 31 months for all patients, the incidence of late grade 2 GU and GI toxicity was 21% and 9%, respectively. Grade ≥ 3 GU and GI toxicity rates were 4% and 1%, respectively, including one patient with a rectal fistula and one patient with a severe hemorrhagic cystitis (both grade 4). In conclusion, high-dose intensity-modulated radiotherapy with fiducial marker-based position verification is well tolerated. The low grade ≥ 3 toxicity allows further dose escalation if the same dose constraints for the organs at risk will be used.</p

    Clinical feasibility study for the use of implanted gold seeds in the prostate as reliable positioning markers during megavoltage irradiation

    No full text
    BACKGROUND AND PURPOSE: The aim of this study was to assess the feasibility of using gold seed implants in the prostate for position verification, using an a-Si flat panel imager as a detector during megavoltage irradiation of prostate carcinoma. This is a study to guarantee positioning accuracy in intensity-modulated radiotherapy. METHODS AND MATERIALS: Ten patients with localized prostate carcinoma (T2-3) received between one and three fiducial gold markers in the prostate. All patients were treated with 3-D conformal radiotherapy with an anterior-posterior (AP) and two lateral wedge fields. The acute gastrointestinal (GI) and genitourinary (GU) toxicities were scored using common toxicity criteria scales (CTC). Using three consecutive CT scans and portal images obtained during the treatment we have studied the occurrence of any change in prostate shape (deformation), seed migration and the magnitude of translations and rotations of the prostate. RESULTS: We observed no acute major complications for prostate irradiation regarding the seed implantation. The maximum acute GU toxicity grade 2 (dysuria and frequency) was observed in seven patients during the treatment. The maximum grade 2 (diarrhoea) was scored in two patients regarding the acute GI toxicities. No significant prostate deformation could be detected in the consecutive CT scans. It appeared that the distances between the markers only slightly changed during treatment (S.D. 0.5 mm). Random prostate translations were (1 S.D.) 2.1, 3.2 and 2.2 mm in the lateral (LR), AP and cranial-caudal (CC) directions, respectively, whereas systematic translations were 3.3, 4.8 and 3.5 mm in the LR, AP and CC directions, respectively. Random prostate rotations were (1 S.D.) 3.6, 1.7 and 1.9 degrees around the LR, AP and CC axis, respectively, whereas systematic rotations were 4.7, 2.0 and 2.7 degrees around the LR, AP and CC axis, respectively. CONCLUSIONS: We found that the fiducial gold seeds are a safe and appropriate device to verify and correct the position of prostate during megavoltage irradiation. The amount of seed migration and prostate deformation is far below our present tumour delineation accurac
    corecore