47 research outputs found
Bail‐out treatment of pulmonary embolism using a large‐bore aspiration mechanical thrombectomy device
We report on thefirst pulmonary embolism treatment via the large-bore aspiration mechanical thrombectomy device (InariFlowTriever®) outside the USA, in a resuscitated patient on veno-arterial extracorporeal membrane oxygenation (VA-ECMO)suffering from severe and acute right heart failure. In this particular high-risk patient population, where thrombolysis is mostlynot applicable, this new technology could be a promising solution as the combination of large-bore thrombus aspiration andextraction successfully removes large emboli. In our case, right ventricular function improved rapidly after the procedure,ECMO could be weaned, and the patient was dismissed 2 weeks after. In summary, we provide a new therapeutic optionfor the often difficult treatment of pulmonary embolism in high-risk patients on VA-ECMO
Less major bleeding and higher hemoglobin after left atrial appendage closure in high‐risk patients: Data from a long‐term, longitudinal, two‐center observational study
Background
Left atrial appendage closure (LAAC) is a mechanical alternative for stroke prevention in patients at risk who cannot tolerate oral anticoagulation (OAC).
Hypothesis
Our hypothesis was that the reduction of anticoagulation following LAAC results in a decrease of bleeding events and a rise in serum hemoglobin in a high-risk collective of patients with atrial fibrillation (AF).
Methods
Bleeding events, use of erythrocyte concentrates, anticoagulation, embolic events, and serum hemoglobin levels before and following LAAC were compared over more than 4 years.
Results
Seventy-five patients (CHA₂DS₂-VASc score 4.4 ± 1.7, HAS-BLED score 4.6 ± 1.1) were analyzed. Before LAAC (observation period 1.8 ± 1.8 years), 67 patients experienced 1.8 ± 1.4 bleeding events (0.9 ± 1.3 major) per year resulting in 0.7 ± 1.3 transfusions per year. After LAAC (2.6 ± 2.0 years), 26 patients (p < .0001 vs. before) had 0.6 ± 2.1 bleeding events (p < .0001), 0.2 ± 0.6 major bleedings (p < .0001) and received 0.6 ± 1.9 transfusions per year (p = .671). Fourteen patients had stroke before and 3 after LAAC (p = .008). Serum hemoglobin increased from initially 9.9 ± 3.0 to 11.9 ± 2.3 g/dL until the end of follow-up (p = .0005). Adverse embolic events did not differ before and after LAAC in our collective.
Conclusion
In this clinical relevant cohort of AF patients with high risk for stroke and intolerance to OAC, we show that LAAC was able to reduce the rate of stroke and bleeding events, which translated into a rising serum hemoglobin concentration
Occurrence of Coronary Collaterals in Acute Myocardial Infarction and Sleep Apnea
Background
In patients with acute myocardial infarction (MI), cardioprotective effects of obstructive sleep apnea are postulated on account of hypoxemic preconditioning. The aim of this single‐center substudy was to investigate a potential association between obstructive sleep apnea and the presence of coronary collaterals in patients with first‐time acute MI who have been enrolled in an ongoing, multicenter clinical trial.
Methods and Results
In TEAM‐ASV I (Treatment of Sleep Apnea Early After Myocardial Infarction With Adaptive Servo‐Ventilation Trial; NCT02093377) patients with first acute MI who received a coronary angiogram within 24 hours after onset of symptoms underwent polygraphy within the first 3 days. Coronary collaterals were classified visually by assigning a Cohen‐Rentrop Score (CRS) ranging between 0 (no collaterals) and 3. Of 94 analyzed patients, 14% had significant coronary collaterals with a CRS ≥2. Apnea‐Hypopnea Index (AHI) score was significantly higher in patients with CRS ≥2 compared with those with CRS <2 (31/hour [11–54] versus 13/hour [4–27]; P=0.032). A multivariable regression model revealed a significant association between obstructive AHI and CRS ≥2 that was independent of age, sex, body mass index, and culprit lesion left anterior descending artery (odds ratio [OR], 1.06; 95% CI, 1.01–1.12; P=0.023), but no significant association between coronary collaterals and central AHI (OR, 1.02; 95% CI, 0.97–1.08; P=0.443).
Conclusions
Patients with first‐time acute MI had more extensive coronary collateralization with an increased AHI or rather an increased obstructive AHI. This finding supports the hypothesis that obstructive sleep apnea exerts potential cardioprotective effects, in addition to its known deleterious effects, in patients with acute MI
Left atrial strain parameters derived by echocardiography are impaired in patients with acute myocarditis and preserved systolic left ventricular function
Purpose:
Data derived by cardiac magnetic resonance (CMR) feature tracking suggest that not only left ventricular but also left atrial function is impaired in patients with acute myocarditis. Therefore, we investigated the diagnostic value of speckle tracking echocardiography of the left ventricle and left atrium in patients with acute myocarditis and normal left ventricular ejection fraction (LVEF). Methods and results:
30 patients with acute myocarditis confirmed by CMR according to the Lake Louise criteria and 20 healthy controls were analyzed including global longitudinal strain (GLS) and left atrial (LA) strain parameters. Although preserved LVEF was present in both groups, GLS was significantly lower in patients with acute myocarditis (GLS − 19.1 ± 1.8% vs. GLS − 22.1 ± 1.7%, p < 0.001). Further diastolic dysfunction measured by E/e’ mean was significantly deteriorated in the myocarditis group compared to the control group (E/e’ mean 6.4 ± 1.6 vs. 5.5 ± 1.0, p = 0.038). LA reservoir function (47.6 ± 10.4% vs. 55.5 ± 10.8%, p = 0.013) and LA conduit function (-33.0 ± 9.6% vs. -39.4 ± 9.5%, p = 0.024) were significantly reduced in patients with acute myocarditis compared to healthy controls. Also left atrial stiffness index (0.15 ± 0.05 vs. 0.10 ± 0.03, p = 0.003) as well as left atrial filling index (1.67 ± 0.47 vs. 1.29 ± 0.34, p = 0.004) were deteriorated in patients with myocarditis compared to the control group. Conclusion:
In patients with acute myocarditis and preserved LVEF not only GLS but also LA reservoir function, LA conduit function and left atrial stiffness index as well as left atrial filling index were impaired compared to healthy controls indicating ventricular diastolic dysfunction and elevated LV filling pressures
Reduction of radiation exposure during transcatheter edge‐to‐edge mitral valve repair
Background
Transcatheter mitral valve repair is an increasingly used therapy for mitral regurgitation which requires fluoroscopic guidance. Limiting radiation exposure during lengthy procedures is important for both patient and operator safety. This study aimed to investigate radiation dose during contemporary use of MitraClip implantation and the effects of a dose reduction program.
Methods
A total of 115 patients who underwent MitraClip implantation were prospectively enrolled in a single-center observational study. During the inclusion period, our institution adopted a radiation dose reduction program, comprising lowering of fluoroscopy pulse rate and image target dose. The first 58 patients were treated with conventional fluoroscopy settings, while the following 57 patients underwent the procedure with the newly implemented low dose protocol.
Results
Radiation dose area product significantly decreased after introduction of the low dose protocol (693 [366–1231] vs. 2265 [1517–3914] cGy·cm2, p < 0.001). After correcting for fluoroscopy time, gender and body mass index, the low dose protocol emerged as a strong negative predictor of radiation dose (p < 0.001), reducing dose area product by 64% (95% confidence interval [57–70]). Device time, device success, and procedural safety did not differ between the normal dose and low dose group. Furthermore, the low dose protocol was not associated with an increased incidence of a combined endpoint consisting of death, repeat intervention, or heart surgery during 12 months follow-up.
Conclusion
Reduction of radiation exposure during transcatheter mitral valve repair by 64% is feasible without affecting procedural success or safety
Association of Coronary Collaterals and Myocardial Salvage Measured by Serial Cardiac Magnetic Resonance Imaging after Acute Myocardial Infarction
Background: Coronary collateral flow in angiography has been linked with lower mortality
rates in patients with coronary artery disease. However, the relevance of the underlying mechanism
is sparse. Therefore, we tested the hypothesis that in patients with acute myocardial infarction
(AMI), relevant coronary collateral flow is associated with more salvaged myocardium and lower
risk of developing heart failure. Methods and Results: Patients with first AMI who received a
percutaneous coronary intervention within 24 h after symptom onset were classified visually by
assigning a Cohen–Rentrop Score (CRS) ranging between 0 (no collaterals) and 3 (complete retrograde
filling of the occluded vessel). All 36 patients included in the analysis underwent cardiac magnetic
resonance examination within 3 to 5 days after myocardial infarction and after 12 weeks. Patients
with relevant collateral flow (CRS 2–3) to the infarct-related artery had significantly smaller final
infarct size compared to those without (7 � 4% vs. 20 � 12%, p < 0.001). In addition, both groups
showed improvement in left ventricular ejection fraction early after AMI, whereas the recovery
was greater in CRS 2–3 (+8 � 5% vs. +3 � 5%, p = 0.015). Conclusion: In patients with first AMI,
relevant collateral flow to the infarct-related artery was associated with more salvaged myocardium
at 12 weeks, translating into greater improvement of systolic left ventricular function. The protective
effect of coronary collaterals and the variance of infarct location should be further investigated in
larger studies
Central Sleep Apnea Is Associated with an Abnormal P-Wave Terminal Force in Lead V1 in Patients with Acute Myocardial Infarction Independent from Ventricular Function
Sleep-disordered breathing (SDB) is highly prevalent in patients with cardiovascular disease. We have recently shown that an elevation of the electrocardiographic (ECG) parameter P wave terminal force in lead V1 (PTFV1) is linked to atrial proarrhythmic activity by stimulation of reactive oxygen species (ROS)-dependent pathways. Since SDB leads to increased ROS generation, we aimed to investigate the relationship between SDB-related hypoxia and PTFV1 in patients with first-time acute myocardial infarction (AMI). We examined 56 patients with first-time AMI. PTFV1 was analyzed in 12-lead ECGs and defined as abnormal when ≥4000 µV*ms. Polysomnography (PSG) to assess SDB was performed within 3–5 days after AMI. SDB was defined by an apnea-hypopnea-index (AHI) >15/h. The multivariable regression analysis showed a significant association between SDB-related hypoxia and the magnitude of PTFV1 independent from other relevant clinical co-factors. Interestingly, this association was mainly driven by central but not obstructive apnea events. Additionally, abnormal PTFV1 was associated with SDB severity (as measured by AHI, B 21.495; CI [10.872 to 32.118]; p < 0.001), suggesting that ECG may help identify patients suitable for SDB screening. Hypoxia as a consequence of central sleep apnea may result in atrial electrical remodeling measured by abnormal PTFV1 in patients with first-time AMI independent of ventricular function. The PTFV1 may be used as a clinical marker for increased SDB risk in cardiovascular patients
Predictors of functional improvement in the short term after MitraClip implantation in patients with secondary mitral regurgitation
Background and objectives MitraClip implantation is an established therapy for secondary mitral regurgitation (MR) in high-risk patients and has shown to improve several important outcome parameters such as functional capacity. Patient selection is both challenging and crucial for achieving therapeutic success. This study investigated baseline predictors of functional improvement as it was quantified by the six-minute walk distance (6MWD) after transcatheter mitral valve repair. Methods and results We retrospectively analyzed 79 patients with secondary MR treated with MitraClip implantation at an academic tertiary care center. Before and four weeks after the procedure, all patients underwent comprehensive clinical assessment, six-minute walk tests and echocardiography. 6MWD significantly improved after MitraClip therapy (295 m vs. 265 m, p < 0.001). A linear regression model including seven clinical baseline variables significantly predicted the change in 6MWD (p = 0.002, R-2 = 0.387). Female gender, diabetes mellitus and arterial hypertension were found to be significant negative predictors of 6MWD improvement. At baseline, female patients had significant higher left ventricular ejection fraction (49% vs. 42%, p = 0.019) and lower 6MWD (240 m vs. 288 m, p = 0.034) than male patients. Conclusion MitraClip implantation in secondary MR significantly improves functional capacity in high risk patients even in the short term of four weeks after the procedure. Female gender, diabetes mellitus and arterial hypertension are baseline predictors of a less favourable functional outcome. While further validation in a larger cohort is recommended, these parameters may improve patient selection for MitraClip therapy
Electrocardiographic diagnosis of left ventricular hypertrophy in aortic valve disease: evaluation of ECG criteria by cardiovascular magnetic resonance
<p>Abstract</p> <p>Background</p> <p>Left ventricular hypertrophy (LVH) is a hallmark of chronic pressure or volume overload of the left ventricle and is associated with risk of cardiovascular morbidity and mortality. The purpose was to evaluate different electrocardiographic criteria for LVH as determined by cardiovascular magnetic resonance (CMR). Additionally, the effects of concentric and eccentric LVH on depolarization and repolarization were assessed.</p> <p>Methods</p> <p>120 patients with aortic valve disease and 30 healthy volunteers were analysed. As ECG criteria for LVH, we assessed the Sokolow-Lyon voltage/product, Gubner-Ungerleider voltage, Cornell voltage/product, Perugia-score and Romhilt-Estes score.</p> <p>Results</p> <p>All ECG criteria demonstrated a significant correlation with LV mass and chamber size. The highest predictive values were achieved by the Romhilt-Estes score 4 points with a sensitivity of 86% and specificity of 81%. There was no difference in all ECG criteria between concentric and eccentric LVH. However, the intrinsicoid deflection (V6 37 ± 1.0 ms vs. 43 ± 1.6 ms, p < 0.05) was shorter in concentric LVH than in eccentric LVH and amplitudes of ST-segment (V5 -0.06 ± 0.01 vs. -0.02 ± 0.01) and T-wave (V5 -0.03 ± 0.04 vs. 0.18 ± 0.05) in the anterolateral leads (p < 0.05) were deeper.</p> <p>Conclusion</p> <p>By calibration with CMR, a wide range of predictive values was found for the various ECG criteria for LVH with the most favourable results for the Romhilt-Estes score. As electrocardiographic correlate for concentric LVH as compared with eccentric LVH, a shorter intrinsicoid deflection and a significant ST-segment and T-wave depression in the anterolateral leads was noted.</p