592 research outputs found

    Technical and economic analysis of the reconversion of an existing biogas plant to biomethane production: a case study.

    Get PDF
    The paper deals with the technical and economic analysis of a project aimed at transforming an existing plant, used for the anaerobic digestion of zoo-technical and agroforest biomass and including a CHP system of about 1 MW of electric capacity, into a facility producing bio-methane for automotive and/or stationary power applications. A comparison of different biogas upgrading technologies is performed, aimed at selecting the technology most appropriate to the size and typology of application under evaluation. Similarly, an analysis is performed to evaluate the opportunity of installing a bio-methane liquefaction facility, to simplify the management and transportation of the fuel, to be used in vehicles. The economic analysis is performed by considering the incentives presently available in Italy for bio-methane producers. Different scenarios are analyzed and discussed, and it was concluded that the conversion of the existing plant into a facility to produce bio-methane to be liquified and sold as fuel for vehicles represents at this moment a very attractive and profitable option

    X-ray detection with a scintillating YAP-window hybrid photomultiplier tube

    Get PDF
    A YAP(YAlO/sub 3/:Ce)-scintillating window, coated on its inner surface with an S20-photocathode, seals a cross-focusing hybrid photomultiplier tube (HPMT) equipped with a small p-i-n anode of 2-mm diameter. This new radiation detector separates X-ray lines down to about 2-keV peak energy from the HPMT noise. Its detection efficiency for high gamma energies depends on the YAP-window thickness and amounts to about 18% attenuation at 400-keV energy in the present version. Competitive radiation detectors like Si photodiodes and Si drift chambers are discussed and compared to our prototype, with particular attention given to their energy resolution and noise performance, which limits their active area considerably. (19 refs)

    An ISPA-camera for gamma rays

    Get PDF
    With the recently developed ISPA (Imaging Silicon Pixel Array)-tube attached either to a planar YAlO3(Ce) (YAP) disc (1mm thick) or to a matrix of optically-separated YAP-crystals (5mm high, 0.6 x 0.6 mm2 cross-section) we achieved high spatial resolution of 57Co-122 keV photons. The vacuum-sealed ISPA-tube is only 4 cm long with 3.5 cm diameter and consists of a photocathode viewed at 3 cm distance by a silicon pixel chip, directly detecting the photoelectrons. The chip-anode consists of 1024 rectangular pixels with 75 µm x 500 µm edges, each bump-bonded to their individual front-end electronics. The total pixel array read-out time is 10 µs. The measured intrinsic spatial resolutions (FWHM) of this ISPA-camera are 700 µm (planar YAP) and 310 µm (YAP-matrix). Apart from its already demonstrated application for particle tracking with scintillating fibres, the ISPA-tube provides also an excellent tool in medicine, biology and chemistry

    Dedicated multichannel readout ASIC coupled with single crystal diamond for dosimeter application

    Get PDF
    This paper reports on the tests of a low-noise, multi-channel readout integrated circuit used as a readout electronic front-end for a diamond multi-pixel dosimeter. The system is developed for dose distribution measurement in radiotherapy applications. The first 10-channel prototype chip was designed and fabricated in a 0.18 um CMOS process. Every channel includes a charge integrator with a 10 pF capacitor and a double slope A/D converter. The diamond multi-pixel detector, based on CVD synthetic single crystal diamond Schottky diodes, is made by a 3 × 3 sensor matrix. The overall device has been tested under irradiation with 6 MeV radio therapeutic photon beams at the Policlinico ``Tor Vergata'' (PTV) hospital. Measurements show a 20 fA RMS leakage current from the front-end input stage and a negligible dark current from the diamond detector, a stable temporal response and a good linear behaviour as a function of both dose and dose rate. These characteristics were common to each tested channel

    Search for Charginos with a Small Mass Difference with the Lightest Supersymmetric Particle at \sqrt{s} = 189 GeV

    Get PDF
    A search for charginos nearly mass-degenerate with the lightest supersymmetric particle is performed using the 176 pb^-1 of data collected at 189 GeV in 1998 with the L3 detector. Mass differences between the chargino and the lightest supersymmetric particle below 4 GeV are considered. The presence of a high transverse momentum photon is required to single out the signal from the photon-photon interaction background. No evidence for charginos is found and upper limits on the cross section for chargino pair production are set. For the first time, in the case of heavy scalar leptons, chargino mass limits are obtained for any \tilde{\chi}^{+-}_1 - \tilde{\chi}^0_1 mass difference

    Search for Charged Higgs Bosons in e+e- Collisions at \sqrt{s} = 189 GeV

    Full text link
    A search for pair-produced charged Higgs bosons is performed with the L3 detector at LEP using data collected at a centre-of-mass energy of 188.6 GeV, corresponding to an integrated luminosity of 176.4 pb^-1. Higgs decays into a charm and a strange quark or into a tau lepton and its associated neutrino are considered. The observed events are consistent with the expectations from Standard Model background processes. A lower limit of 65.5 GeV on the charged Higgs mass is derived at 95 % confidence level, independent of the decay branching ratio Br(H^{+/-} -> tau nu)

    Photodetector and scintillation crystals requirements for gamma-ray imaging

    Get PDF
    The diffusion of the PET and SPET techniques in different applications, like investigation on small organs and tissues or animal imaging, has induced in the past years the researchers to develop modular scintillation cameras to have compactness and versatility in order to obtain dimensions and configurations suitable to the particular application. To this purpose different photodetectors have been studied, as an alternative to the photomultiplier tubes (PMT) based on semiconductor technology. At the same time new scintillating crystals have been tested to match the requirements like high light yield or fast decay time, needed for SPET and PET application, respectively. In this paper we have investigated the photodetector and scintillation crystals requirements to optimize a gamma-ray imager based on scintillation crystals. To this aim we show results about the principal parameters characterizing a gamma-ray imaging, like energy and spatial resolution. The performances of a continuous LaBr3:Ce crystal (49×49×4mm3+3mm glass window) are compared to the ones from a pixellated and continuous NaI:Tl crystal, coupled to multi-anode photomultiplier tube (Hamamatsu H8500 MA-PMT). Furthermore the results are supported with Monte Carlo simulations. With the lanthanum detector, we obtain 1.1mm of intrinsic spatial resolution, comparable with that predicted by the MC simulations. We test also the new ultra bialkali PMT Hamamatsu R7600-200 with a QE = 42%, obtaining an improvement in terms of energy resolution of about 25%, respect to a standard PMT, with a LaBr3:Ce cylinder (1/2" ��φ × 1/2" thickness)

    Study of Spin and Decay-Plane Correlations of W Bosons in the e+e- -> W+W- Process at LEP

    Get PDF
    Data collected at LEP at centre-of-mass energies \sqrt(s) = 189 - 209 GeV are used to study correlations of the spin of W bosons using e+e- -> W+W- -> lnqq~ events. Spin correlations are favoured by data, and found to agree with the Standard Model predictions. In addition, correlations between the W-boson decay planes are studied in e+e- -> W+W- -> lnqq~ and e+e- -> W+W- -> qq~qq~ events. Decay-plane correlations, consistent with zero and with the Standard Model predictions, are measured

    Search for an Invisibly-Decaying Higgs Boson at LEP

    Get PDF
    A search for a Higgs boson produced in e^+e^- collisions in association with a Z boson and decaying into invisible particles is performed. Data collected at LEP with the L3 detector at centre-of-mass energies from 189 GeV to 209 GeV are used, corresponding to an integrated luminosity of 0.63/fb. Events with hadrons, electrons or muons with visible masses compatible with a Z boson and missing energy and momentum are selected. They are consistent with the Standard Model expectations. A lower limit of 112.3 GeV is set at 95% confidence level on the mass of the invisibly-decaying Higgs boson in the hypothesis that its production cross section equals that of the Standard Model Higgs boson. Relaxing this hypothesis, upper limits on the production cross section are derived
    corecore