7 research outputs found

    Device-related complications in the subcutaneous and transvenous ICD: a secondary analysis of the PRAETORIAN trial.

    Get PDF
    BACKGROUND: The subcutaneous ICD (S-ICD) is developed to overcome lead-related complications and systemic infections, inherent to transvenous ICD (TV-ICD) therapy. The PRAETORIAN trial demonstrated that the S-ICD is non-inferior to the TV-ICD with regard to the combined primary endpoint of inappropriate shocks and complications. This prespecified secondary analysis evaluates all complications in the PRAETORIAN trial. METHODS: The PRAETORIAN trial is an international, multicenter, randomised trial in which 849 patients with an indication for ICD therapy were randomised to receive an SICD (N = 426) or TV-ICD (N = 423) and followed for a median of 49 months. Endpoints were device-related complications, lead-related complications, systemic infections and the need for invasive interventions. RESULTS: Thirty-six device-related complications occurred in 31 patients in the S-ICD group of which bleedings were the most frequent. In the TV-ICD group 49 complications occurred in 44 patients of which lead-dysfunction was most frequent (HR 0.69; P =0.11). In both groups half of all complications were within 30 days after implantation. Lead-related complications and systemic infections occurred significantly less in the S-ICD group compared to the TV-ICD group (P <0.001, P =0.03 respectively). Significantly more complications required invasive interventions in the TV-ICD group compared to the S-ICD group (8.3% vs. 4.3%, HR 0.59; P =0.047). CONCLUSIONS: This secondary analysis shows that, lead-related complications and systemic infections are more prevalent in the TV-ICD group compared to the S-ICD group. In addition, complications in the TV-ICD group were more severe as they required significantly more invasive interventions. This data contributes to shared decision making in clinical practice

    Efficacy and Safety of Appropriate Shocks and Antitachycardia Pacing in Transvenous and Subcutaneous Implantable Defibrillators: Analysis of All Appropriate Therapy in the PRAETORIAN Trial.

    Get PDF
    BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) showed noninferiority of subcutaneous implantable cardioverter defibrillator (S-ICD) compared with transvenous implantable cardioverter defibrillator (TV-ICD) with regard to inappropriate shocks and complications. In contrast to TV-ICD, S-ICD cannot provide antitachycardia pacing for monomorphic ventricular tachycardia. This prespecified secondary analysis evaluates appropriate therapy and whether antitachycardia pacing reduces the number of appropriate shocks. METHODS: The PRAETORIAN trial was an international, investigator-initiated randomized trial that included patients with an indication for implantable cardioverter defibrillator (ICD) therapy. Patients with previous ventricular tachycardia <170 bpm or refractory recurrent monomorphic ventricular tachycardia were excluded. In 39 centers, 849 patients were randomized to receive an S-ICD (n=426) or TV-ICD (n=423) and were followed for a median of 49.1 months. ICD programming was mandated by protocol. Appropriate ICD therapy was defined as therapy for ventricular arrhythmias. Arrhythmias were classified as discrete episodes and storm episodes (≥3 episodes within 24 hours). Analyses were performed in the modified intention-to-treat population. RESULTS: In the S-ICD group, 86 of 426 patients received appropriate therapy, versus 78 of 423 patients in the TV-ICD group, during a median follow-up of 52 months (48-month Kaplan-Meier estimates 19.4% and 17.5%; P=0.45). In the S-ICD group, 83 patients received at least 1 shock, versus 57 patients in the TV-ICD group (48-month Kaplan-Meier estimates 19.2% and 11.5%; P=0.02). Patients in the S-ICD group had a total of 254 shocks, compared with 228 shocks in the TV-ICD group (P=0.68). First shock efficacy was 93.8% in the S-ICD group and 91.6% in the TV-ICD group (P=0.40). The first antitachycardia pacing attempt successfully terminated 46% of all monomorphic ventricular tachycardias, but accelerated the arrhythmia in 9.4%. Ten patients with S-ICD experienced 13 electrical storms, versus 18 patients with TV-ICD with 19 electrical storms. Patients with appropriate therapy had an almost 2-fold increased relative risk of electrical storms in the TV-ICD group compared with the S-ICD group (P=0.05). CONCLUSIONS: In this trial, no difference was observed in shock efficacy of S-ICD compared with TV-ICD. Although patients in the S-ICD group were more likely to receive an ICD shock, the total number of appropriate shocks was not different between the 2 groups. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01296022

    Platelets and cardiac arrhythmia

    No full text
    \u3cp\u3eSudden cardiac death (SCD) remains one of the most prevalent modes of death in industrialized countries, and myocardial ischemia due to thrombotic coronary occlusion is its primary cause. The role of platelets in the occurrence of SCD extends beyond coronary flow impairment by clot formation. Here we review the substances released by platelets during clot formation and their arrhythmic properties. Platelet products are released from three types of platelet granules: dense core granules, alpha-granules, and platelet lysosomes. The physiologic properties of dense granule products are of special interest as a potential source of arrhythmic substances. They are released readily upon activation and contain high concentrations of serotonin, histamine, purines, pyrimidines, and ions such as calcium and magnesium. Potential arrhythmic mechanisms of these substances, e.g., serotonin and high energy phosphates, include induction of coronary constriction, calcium overloading, and induction of delayed after-depolarizations. Alpha-granules produce thromboxanes and other arachidonic-acid products with many potential arrhythmic effects mediated by interference with cardiac sodium, calcium, and potassium channels. Alpha-granules also contain hundreds of proteins that could potentially serve as ligands to receptors on cardiomyocytes. Lysosomal products probably do not have an important arrhythmic effect. Platelet products and ischemia can induce coronary permeability, thereby enhancing interaction with surrounding cardiomyocytes. Antiplatelet therapy is known to improve survival after myocardial infarction. Although an important part of this effect results from prevention of coronary clot formation, there is evidence to suggest that antiplatelet therapy also induces anti-arrhythmic effects during ischemia by preventing the release of platelet activation products.\u3c/p\u3

    Determinants of label non-adherence to non-vitamin K oral anticoagulants in patients with newly diagnosed atrial fibrillation

    Get PDF
    AIMS: To evaluate the extent and determinants of off-label non-vitamin K oral anticoagulant (NOAC) dosing in newly diagnosed Dutch AF patients. METHODS AND RESULTS: In the DUTCH-AF registry, patients with newly diagnosed AF (<6 months) are prospectively enrolled. Label adherence to NOAC dosing was assessed using the European Medicines Agency labelling. Factors associated with off-label dosing were explored by multivariable logistic regression analyses. From July 2018 to November 2020, 4500 patients were registered. The mean age was 69.6 ± 10.5 years, and 41.5% were female. Of the 3252 patients in which NOAC label adherence could be assessed, underdosing and overdosing were observed in 4.2% and 2.4%, respectively. In 2916 (89.7%) patients with a full-dose NOAC recommendation, 4.6% were underdosed, with a similar distribution between NOACs. Independent determinants (with 95% confidence interval) were higher age [odds ratio (OR): 1.01 per year, 1.01-1.02], lower renal function (OR: 0.96 per ml/min/1.73 m(2), 0.92-0.98), lower weight (OR: 0.98 per kg, 0.97-1.00), active malignancy (OR: 2.46, 1.19-5.09), anaemia (OR: 1.73, 1.08-2.76), and concomitant use of antiplatelets (OR: 4.93, 2.57-9.46). In the 336 (10.3%) patients with a reduced dose NOAC recommendation, 22.9% were overdosed, most often with rivaroxaban. Independent determinants were lower age (OR: 0.92 per year, 0.88-0.96) and lower renal function (OR: 0.98 per ml/min/1.73 m(2), 0.96-1.00). CONCLUSION: In newly diagnosed Dutch AF patients, off-label dosing of NOACs was seen in only 6.6% of patients, most often underdosing. In this study, determinants of off-label dosing were age, renal function, weight, anaemia, active malignancy, and concomitant use of antiplatelets
    corecore