29 research outputs found
Higher return to pre-injury type of sports after revision anterior ligament reconstruction with lateral extra-articular tenodesis compared to without lateral extra-articular tenodesis
PurposeTo evaluate the rate of return to pre-injury type of sports (RTS type) in patients after revision anterior cruciate ligament reconstruction (ACLR) with lateral extra-articular tenodesis (LET) compared to patients after revision ACLR without LET.MethodsSeventy-eight patients who underwent revision ACLR with an autologous ipsilateral bone-patellar tendon-bone autograft with and without LET were included at least one year after surgery (mean follow-up: 43.9, SD: 29.2 months). All patients filled in a questionnaire about RTS type, the Knee injury and Osteoarthritis Outcome Score (KOOS), the International Knee Documentation Committee subjective form (IKDCsubjective), and the Tegner activity score.ResultsThe RTS type for revision ACLR with LET was 22 of 42 (52%), whereas 11 of 36 (31%) of the patients who underwent revision ACLR without LET returned to the pre-injury type of sport (p = 0.05). No significant differences were found in KOOS subscores, IKDCsubjective, and Tegner activity scores.ConclusionAn additional LET increases the rate of RTS type after revision ACLR
A comparison of 3-D CT and 2-D plain radiograph measurements of the wrist in extra-articular malunited fractures of the distal radius
Two-dimensional (2-D) plain radiographs may be insufficient for the evaluation of distal radial malunion, as it is a three-dimensional (3-D) deformity. This study introduced a 3-D measuring method that outputs radial inclination, ulnar variance, palmar tilt and axial rotation. To this end, a standardized and clearly defined coordinate system was constructed that allowed 3-D measurements closely resembling the conventional 2-D method in 35 patients. Mean differences between 3-D and 2-D measurements in affected wrists were 1.8° for radial inclination, 0.8 mm for ulnar variance and 3.7° for palmar tilt. In addition, inter- and intra-observer reproducibility of all 3-D and 2-D measurements were good or excellent (intraclass correlation coefficient >0.75), with 3-D reproducibility always better than 2-D. Axial rotation was present in all patients with a mean of 7.9° (SD 6.9). Although the differences between 2-D and 3-D measurements were small, 3-D evaluation enables the assessment of axial rotation and brings us closer to a routine 3-D evaluation of malunion.</p
Binaural summation, binaural unmasking and fluctuating masker benefit in bimodal and bilateral adult cochlear implant users
OBJECTIVES : The number of bilateral adult cochlear implant (CI) users and bimodal CI users is expanding worldwide. The addition of a hearing aid (HA) in the contralateral non-implanted ear (bimodal) or a second CI (bilateral) can provide CI users with some of the benefits associated with listening with two ears. Our was to examine whether bilateral and bimodal CI users demonstrate binaural summation, binaural unmasking and a fluctuating masker benefit.
METHODS : Direct audio input was used to present stimuli to 10 bilateral and 10 bimodal CochlearTM CI users. Speech recognition in noise (speech reception threshold, SRT) was assessed monaurally, diotically (identical signals in both devices) and dichotically (antiphasic speech) with different masking noises (steady-state and interrupted), using the digits-in-noise test.
RESULTS : Bilateral CI users demonstrated a trend towards better SRTs with both CIs than with one CI. Bimodal CI users showed no difference between the bimodal SRT and the SRT for CI alone. No significant differences in SRT were found between the diotic and dichotic conditions for either group. Analyses of electrodograms created from bilateral stimuli demonstrated that substantial parts of the interaural speech cues were preserved in the Advanced Combination Encoder, an n-of-m channel selection speech coding strategy, used by the CI users. Speech recognition in noise was significantly better with interrupted noise than with steady-state masking noise for both bilateral and bimodal CI users.
CONCLUSION : Bilateral CI users demonstrated a trend towards binaural summation, but bimodal CI users did not. No binaural unmasking was demonstrated for either group of CI users. A large fluctuating masker benefit was found in both bilateral and bimodal CI users.https://www.tandfonline.com/loi/ycii20hj2022Speech-Language Pathology and Audiolog
The Preoperative CT-Scan Can Help to Predict Postoperative Complications after Pancreatoduodenectomy
After pancreatoduodenectomy, complication rates are up to 40%. To predict the risk of developing postoperative pancreatic fistula or severe complications, various factors were evaluated. 110 consecutive patients undergoing pancreatoduodenectomy at our institute between January 2012 and September 2014 with complete CT scan were retrospectively identified. Pre-, per-, and postoperative patients and pathological information were gathered. The CT-scans were analysed for the diameter of the pancreatic duct, attenuation of the pancreas, and the visceral fat area. All data was statistically analysed for predicting POPF and severe complications by univariate and multivariate logistic regression analyses. The POPF rate was 18%. The VFA measured at umbilicus (OR 1.01; 95% CI = 1.00–1.02; P=0.011) was an independent predictor for POPF. The severe complications rate was 33%. Independent predictors were BMI (OR 1.24; 95% CI = 1.10–1.42; P=0.001), ASA class III (OR 17.10; 95% CI = 1.60–182.88; P=0.019), and mean HU (OR 0.98; 95% CI = 0.96–1.00; P=0.024). In conclusion, VFA measured at the umbilicus seems to be the best predictor for POPF. BMI, ASA III, and the mean HU of the pancreatic body are independent predictors for severe complications following PD
Prioritizing cleft/craniofacial surgical care after the COVID-19 pandemic
Background: It is anticipated that in due course the burden of emergency care due to COVID-19 infected patients will reduce sufficiently to permit elective surgical procedures to recommence. Prioritizing cleft/craniofacial surgery in the already overloaded medical system will then become an issue. The European Cleft Palate Craniofacial Association, together with the European Cleft and Craniofacial Initiative for Equality in Care, performed a brief survey to capture a current snapshot during a rapidly evolving pandemic. Methods: A questionnaire was sent to the 2242 participants who attended 1 of 3 recent international cleft/craniofacial meetings. Results: The respondents indicated that children with Robin sequence who were not responding to nonsurgical options should be treated as emergency cases. Over 70% of the respondents indicated that palate repair should be performed before the age of 15 months, an additional 22% stating the same be performed by 18 months. Placement of middle ear tubes, primary cleft lip surgery, alveolar bone grafting, and velopharyngeal insufficiency surgery also need prioritization. Children with craniofacial conditions such as craniosynostosis and increased intracranial pressure need immediate care, whilst children with craniosynostosis and associated obstructive sleep apnea syndrome or proptosis need surgical care within 3 months of the typical timing. Craniosynostosis without signs of increased intracranial pressure needs correction before the age of 18 months. Conclusions: This survey indicates several areas of cleft and craniofacial conditions that need prioritization, but also certain areas where intervention is less urgent. We acknowledge that there will be differences in the post COVID-19 response according to circumstances and policies in individual countries
Patient-Specific Guided Osteotomy to Correct a Symptomatic Malunion of the Left Forearm.
We present a case report of a 12-year old female with a midshaft forearm fracture. Initial conservative treatment with a cast failed, resulting in a malunion. The malunion resulted in functional impairment for which surgery was indicated. A corrective osteotomy was planned using 3D analyses of the preoperative CT-scan. Subsequently, patient-specific guides were printed and used during the procedure to precisely correct the malunion. Three months after surgery, the radiographs showed full consolidation and the patient was pain-free with full range of motion and comparable strength in both forearms. The current case report shows that a corrective osteotomy with patient-specific guides based on preoperative 3D analyses can help surgeons to plan and precisely correct complex malunions resulting in improved functional outcomes
Assessment of speech recognition abilities in quiet and in noise: a comparison between self-administered home testing and testing in the clinic for adult cochlear implant users
Self speech recognition tests in quiet and noise at home are compared to the standard tests performed in the clinic. Potential effects of stimuli presentation modes (loudspeaker or audio cable) and assessment (clinician or self-assessment at home) on test results were investigated. Speech recognition in quiet was assessed using the standard Dutch test with monosyllabic words. Speech recognition in noise was assessed with the digits-in-noise test. Sixteen experienced CI users (aged between 44 and 83 years) participated. No significant difference was observed in speech recognition in quiet between and presentation modes. Speech recognition in noise was significantly better with the audio cable than with the loudspeaker. There was no significant difference in speech recognition in quiet at 65 dB and in speech recognition in noise between self-assessment at home and testing in the clinic. At 55 dB, speech recognition assessed at home was slightly but significantly better than that assessed in the clinic. The results demonstrate that it is feasible for experienced CI users to perform self-administered speech recognition tests at home. Self-assessment by CI users of speech recognition in quiet and noise within the home environment could serve as an alternative to the tests performed in the clinic
Binaural summation, binaural unmasking and fluctuating masker benefit in bimodal and bilateral adult cochlear implant users
OBJECTIVES: The number of bilateral adult cochlear implant (CI) users and bimodal CI users is expanding worldwide. The addition of a hearing aid (HA) in the contralateral non-implanted ear (bimodal) or a second CI (bilateral) can provide CI users with some of the benefits associated with listening with two ears. Our was to examine whether bilateral and bimodal CI users demonstrate binaural summation, binaural unmasking and a fluctuating masker benefit. METHODS: Direct audio input was used to present stimuli to 10 bilateral and 10 bimodal CochlearTM CI users. Speech recognition in noise (speech reception threshold, SRT) was assessed monaurally, diotically (identical signals in both devices) and dichotically (antiphasic speech) with different masking noises (steady-state and interrupted), using the digits-in-noise test. RESULTS: Bilateral CI users demonstrated a trend towards better SRTs with both CIs than with one CI. Bimodal CI users showed no difference between the bimodal SRT and the SRT for CI alone. No significant differences in SRT were found between the diotic and dichotic conditions for either group. Analyses of electrodograms created from bilateral stimuli demonstrated that substantial parts of the interaural speech cues were preserved in the Advanced Combination Encoder, an n-of-m channel selection speech coding strategy, used by the CI users. Speech recognition in noise was significantly better with interrupted noise than with steady-state masking noise for both bilateral and bimodal CI users. CONCLUSION: Bilateral CI users demonstrated a trend towards binaural summation, but bimodal CI users did not. No binaural unmasking was demonstrated for either group of CI users. A large fluctuating masker benefit was found in both bilateral and bimodal CI users