73 research outputs found

    Bile Duct Injury After Single Incision Laparoscopic Cholecystectomy

    Get PDF
    This study notes that the development of single-incision laparoscopic surgery is not without risk and that obtaining the critical view in appropriately selected patients is essential for safe single-incision laparoscopic surgery

    Evaluation of ECHO PS Positioning System in a Porcine Model of Simulated Laparoscopic Ventral Hernia Repair

    Get PDF
    Purpose. Operative efficiency improvements for laparoscopic ventral hernia repair (LVHR) have focused on reducing operative time while maintaining overall repair efficacy. Our objective was to evaluate procedure time and positioning accuracy of an inflatable mesh positioning device (Echo PS Positioning System), as compared to a standard transfascial suture technique, using a porcine model of simulated LVHR. Methods. The study population consisted of seventeen general surgeons (n = 17) that performed simulated LVHR on seventeen (n = 17) female Yorkshire pigs using two implantation techniques: (1) Ventralight ST Mesh + Echo PS Positioning System (Echo PS) and (2) Ventralight ST Mesh + transfascial sutures (TSs). Procedure time and mesh centering accuracy overtop of a simulated surgical defect were evaluated. Results. Echo PS demonstrated a 38.9% reduction in the overall procedure time, as compared to TS. During mesh preparation and positioning, Echo PS demonstrated a 60.5% reduction in procedure time (P \u3c 0.0001). Although a trend toward improved centering accuracy was observed for Echo PS (16.2%), this was not significantly different than TS. Conclusions. Echo PS demonstrated a significant reduction in overall simulated LVHR procedure time, particularly during mesh preparation/positioning. These operative time savings may translate into reduced operating room costs and improved surgeon/operating room efficiency

    Evaluation of Composite Mesh for Ventral Hernia Repair

    Get PDF
    Composite mesh was associated with minimal intraabdominal adhesions, progressive in-growth of host tissue, and complete degradation of an internal polydioxanone ring that was of assistance in mesh positioning

    Current trends in vena cava reconstructive techniques with major liver resection: a systematic review

    Full text link
    Purpose: Historically, invasion of the inferior vena cava (IVC) represented advanced and often unresectable hepatic disease. With surgical and anesthetic innovations, IVC resection and reconstruction have become feasible in selected patients. This review assesses technical variations in reconstructive techniques and post-operative management. Methods: A comprehensive literature search was performed according to PRISMA. Inclusion criteria were (i) peer-reviewed articles in English; (ii) at least three cases; (iii) hepatic IVC resection and reconstruction (January 2015-March 2020). Primary outcomes were reconstructive technique, anti-thrombotic regimen, post-operative IVC patency, and infection. Secondary outcomes included post-operative complications and malignant disease survival. Results: Fourteen articles were included allowing for investigation of 351 individual patients. Analysis demonstrated significant heterogeneity in surgical reconstructive technique, anti-thrombotic management, and post-operative monitoring of patency. There was increased utilization of ex vivo approaches and decreased use of venovenous bypass compared with previously published reviews. Conclusion: This review of literature published between 2015 and 2020 reveals persistent heterogeneity of hepatic IVC reconstructive techniques and peri-operative management. Increased utilization of ex vivo approaches and decreased use of venovenous bypass point towards improved operative techniques, peri-operative management, and anesthesia. In order to gain evidence for consensus on management, a registry would be beneficial

    Role of yttrium-90 selective internal radiation therapy in the treatment of liver-dominant metastatic colorectal cancer: An evidence-based expert consensus algorithm

    Get PDF
    Surgical resection of colorectal liver metastases is associated with greater survival compared with non-surgical treatment, and a meaningful possibility of cure. However, the majority of patients are not eligible for resection and may require other non-surgical interventions, such as liver-directed therapies, to be converted to surgical eligibility. Given the number of available therapies, a general framework is needed that outlines the specific roles of chemotherapy, surgery, and locoregional treatments [including selective internal radiation therapy (SIRT) with Y-90 microspheres]. Using a data-driven, modified Delphi process, an expert panel of surgical oncologists, transplant surgeons, and hepatopancreatobiliary (HPB) surgeons convened to create a comprehensive, evidence-based treatment algorithm that includes appropriate treatment options for patients stratified by their eligibility for surgical treatment. The group coined a novel, more inclusive phrase for targeted locoregional tumor treatment (a blanket term for resection, ablation, and other emerging locoregional treatments)

    Evaluation of E CHO

    Get PDF
    Purpose. Operative efficiency improvements for laparoscopic ventral hernia repair (LVHR) have focused on reducing operative time while maintaining overall repair efficacy. Our objective was to evaluate procedure time and positioning accuracy of an inflatable mesh positioning device (Echo PS Positioning System), as compared to a standard transfascial suture technique, using a porcine model of simulated LVHR. Methods. The study population consisted of seventeen general surgeons (n = 17) that performed simulated LVHR on seventeen (n = 17) female Yorkshire pigs using two implantation techniques: (1) Ventralight ST Mesh + Echo PS Positioning System (Echo PS) and (2) Ventralight ST Mesh + transfascial sutures (TSs). Procedure time and mesh centering accuracy overtop of a simulated surgical defect were evaluated. Results. Echo PS demonstrated a 38.9% reduction in the overall procedure time, as compared to TS. During mesh preparation and positioning, Echo PS demonstrated a 60.5% reduction in procedure time (P < 0.0001). Although a trend toward improved centering accuracy was observed for Echo PS (16.2%), this was not significantly different than TS. Conclusions. Echo PS demonstrated a significant reduction in overall simulated LVHR procedure time, particularly during mesh preparation/positioning. These operative time savings may translate into reduced operating room costs and improved surgeon/operating room efficiency
    • …
    corecore