734 research outputs found

    Towards a time-reversal mirror for quantum systems

    Full text link
    The reversion of the time evolution of a quantum state can be achieved by changing the sign of the Hamiltonian as in the polarization echo experiment in NMR. In this work we describe an alternative mechanism inspired by the acoustic time reversal mirror. By solving the inverse time problem in a discrete space we develop a new procedure, the perfect inverse filter. It achieves the exact time reversion in a given region by reinjecting a prescribed wave function at its periphery.Comment: 6 pages, 4 figures. Introduction modified, references added, one figure added to improve the discussio

    Role of PET/CT in the detection of liver metastases from colorectal cancer

    Get PDF
    The aim of this study was to compare the diagnostic accuracy of 2-[fluorine-18] fluoro-2-deoxy-D-glucose positron emission tomography (F-18-FDG-PET) and computed tomography (CT) with PET/CT in the detection of liver metastases during tumour staging in patients suffering from colorectal carcinoma for the purposes of correct surgical planning and follow-up. A total of 467 patients underwent a PET/CT scan using an iodinated contrast medium. We compared images obtained by the single PET scan, the single CT scan and by the fusion of the two procedures (PET/CT). The final diagnosis was obtained by histological examination and/or by the follow-up of all patients, including those who did not undergo surgery or biopsy. The PET scan had 94.05% sensitivity, 91.60% specificity and 93.36% accuracy; the CT scan had 91.07% sensitivity, 95.42% specificity and 92.29% accuracy. The combined procedures (PET/CT) had the following values: sensitivity 97.92%, specificity 97.71% and accuracy 97.86%. This study indicates that PET/CT is very useful in staging and restaging patients suffering from colorectal cancer. It was particularly useful when recurrences could not be visualised either clinically or by imaging despite increasing tumour markers, as it guaranteed an earlier diagnosis. PET/CT not only provides high diagnostic performance in terms of sensitivity and specificity, enabling modification of patient treatment, but it is also a unique, high-profile procedure that can produce cost savings

    Involvement of subcortical brain structures during olfactory stimulation in multiple chemical sensitivity

    Get PDF
    Multiple chemical sensitivity (MCS) patients usually react to odour compounds and the majority of neuroimaging studies assessed, especially at the cortical level, many olfactory-related correlates. The purpose of the present study was to depict sub-cortical metabolic changes during a neutral (NC) and pure (OC) olfactory stimulation by using a recently validated 18F-2-fluoro-2-deoxy-D-glucose (FDG)-positron emission tomography/computer tomography procedure in 26 MCS and 11 healthy (HC) resting subjects undergoing a battery of clinical tests. Twelve subcortical volumes of interest were identified by the automated anatomical labeling library and normalized to thalamus FDG uptake. In both groups, when comparing OC to NC, the within-subjects ANOVA demonstrated a relative decreased metabolism in bilateral putamen and hippocampus and a relative increased metabolism in bilateral amygdala, olfactory cortex (OLF), caudate and pallidum. The between-groups ANOVA demonstrated in MCS a significant higher metabolism in bilateral OLF during NC. As in HC subjects negative correlations were found in OC between FDG uptake in bilateral amygdala and hippocampus and odor pleasantness scale, the latter positively correlated with MCS subjects\u27 bilateral putamen FDG uptake in OC. Besides FDG uptake resemblances in both groups were found, for the first time a relative higher metabolism increase in OLF in MCS subjects at rest with respect to HC was found. When merging this aspect to the different subcortical FDG uptake correlations patterns in the two groups, the present study demonstrated to describe a peculiar metabolic index of behavioral and neurological aspects of MCS complaints

    Mutations in the Cardiac Ryanodine Receptor Gene (hRyR2) Underlie Catecholaminergic Polymorphic Ventricular Tachycardia

    Get PDF
    BACKGROUND: Catecholaminergic polymorphic ventricular tachycardia is a genetic arrhythmogenic disorder characterized by stress-induced, bidirectional ventricular tachycardia that may degenerate into cardiac arrest and cause sudden death. The electrocardiographic pattern of this ventricular tachycardia closely resembles the arrhythmias associated with calcium overload and the delayed afterdepolarizations observed during digitalis toxicity. We speculated that a genetically determined abnormality of intracellular calcium handling might be the substrate of the disease; therefore, we considered the human cardiac ryanodine receptor gene (hRyR2) a likely candidate for this genetically transmitted arrhythmic disorder. METHODS AND RESULTS: Twelve patients presenting with typical catecholaminergic polymorphic ventricular tachycardia in the absence of structural heart abnormalities were identified. DNA was extracted from peripheral blood lymphocytes, and single-strand conformation polymorphism analysis was performed on polymerase chain reaction-amplified exons of the hRyR2 gene. Four single nucleotide substitutions leading to missense mutations were identified in 4 probands affected by the disease. Genetic analysis of the asymptomatic parents revealed that 3 probands carried de novo mutations. In 1 case, the identical twin of the proband died suddenly after having suffered syncopal episodes. The fourth mutation was identified in the proband, in 4 clinically affected family members, and in none of 3 nonaffected family members in a kindred with 2 sudden deaths that occurred at 16 and 14 years, respectively, in the sisters of the proband. CONCLUSIONS: We demonstrated that, in agreement with our hypothesis, hRyR2 is a gene responsible for catecholaminergic polymorphic ventricular tachycardia

    Pharmacological characterization of a new Ca2+ sensitizer

    Get PDF
    The benzimidazole molecule was modified to synthesize a Ca(2+) sensitizer devoid of additional effects associated with Ca(2+) overload. Newly synthesized compounds, termed 1, 2, 3, 4, and 5, were evaluated in spontaneously beating and electrically driven atria from reserpine-treated guinea pigs. Compound 3 resulted as the most effective positive inotropic agent, and experiments were performed to study its mechanism of action. In spontaneously beating atria, the inotropic effect of 3 was concentration-dependent (3.0 microM-0.3 mM). Compound 3 was more potent and more active than the structurally related Ca(2+) sensitizers sulmazole and caffeine, but unlike them it did not increase the heart rate. In electrically driven atria, the inotropic activity of 3 was well preserved and it was not inhibited by propranolol, prazosin, ranitidine, pyrilamine, carbachol, adenosine deaminase, or ruthenium red. At high concentrations (0.1-1.0 mM) 3 inhibited phosphodiesterase-III, whereas it did not affect Na(+)/K(+)-ATPase, sarcolemmal Ca(2+)-ATPase, Na(+)/Ca(2+) exchange carrier, or sarcoplasmic reticulum Ca(2+) pump activities of guinea pig heart. In skinned fibers obtained from guinea pig papillary muscle and skeletal soleus muscle, compound 3 (0.1 mM, 1 mM) shifted the pCa/tension relation curve to the left, with no effect on maximal tension and no signs of toxicity. Compound 3 did not influence the basal or raised tone of guinea pig isolated aorta rings, whose cells do not contain the contractile protein troponin. The present results indicate that the inotropic effect of compound 3 seems to be primarily sustained by sensitization of the contractile proteins to Ca(2+)

    Neuropsychological Functioning in Bilateral versus Unilateral Temporal Lobe Epilepsy

    Get PDF
    Although relatively specific anatomo-electro-clinical features of temporal lobe epilepsy (TLE) with bilateral ictal involvement (bitemporal epilepsy-BTLE) have been described, differentiating between BTLE and unilateral TLE (UTLE) remains challenging. Surgery is often the treatment of choice for drug-resistant UTLE, whereas its use is more controversial in BTLE. It is currently unclear whether neuropsychological assessment can contribute to the differential diagnosis. We retrospectively reviewed the neuropsychological evaluation of 46 consecutive patients with refractory TLE. Eighteen patients were diagnosed with BTLE on the basis of ictal electro-clinical data, in particular a video EEG recording of at least one seizure simultaneously involving the two temporal lobes without the possibility of lateralizing its onset or at least two different seizures independently arising from the two temporal lobes. Twenty-eight patients were classified as UTLE. Presurgery evaluation data were used in this study. Compared with UTLE, BTLE was associated with a lower intelligence quotient (IQ) and more severe impairment in long-term memory, the latter remaining significant even after controlling for IQ. No significant differences were found between right and left UTLE. In conclusion, BTLE and UTLE are associated with relatively distinct neuropsychological profiles, further supporting their classification as different disorders within the TLE spectrum

    Quantitative and Qualitative Assessments of Retinal Structure with Variable A-Scan Rate Spectralis OCT: Insights into IPL Multilaminarity

    Get PDF
    The aim of this study was to evaluate the qualitative and quantitative differences between 20 and 85 kHz A-scan rate optical coherence tomography (OCT) images acquired by spectral domain OCT. The study included 60 healthy subjects analyzed with horizontal linear scans with a variable A-scan rate (SHIFT technology, Heidelberg Engineering, Heidelberg, Germany). The retinal thickness measurement of each retinal layer was performed in three different positions (subfoveal, nasal, and temporal). The qualitative assessment was performed by two independent observers who rated every image with a score ranging from 1 ("sufficient") to 3 ("excellent") on the basis of three parameters: visualization of the vitreo-retinal interface, characterization of the retinal layers, and visualization of the sclero-choroidal interface. No statistically significant differences in terms of retinal layer thickness between the two A-scan rate scans were observed (p > 0.05). The coefficient of variation of the retinal thickness values was lower in the 20 kHz group (25.8% versus 30.1% with the 85 kHz). The 20 kHz images showed a higher quality index for both observers. An inner plexiform layer (IPL) multilaminarity was detected in 78.3% of patients from the 20 kHz group and in 40% of patients from the 85 kHz group (p < 0.05)
    corecore