101 research outputs found

    Time and position sensitive single photon detector for scintillator read-out

    Full text link
    We have developed a photon counting detector system for combined neutron and gamma radiography which can determine position, time and intensity of a secondary photon flash created by a high-energy particle or photon within a scintillator screen. The system is based on a micro-channel plate photomultiplier concept utilizing image charge coupling to a position- and time-sensitive read-out anode placed outside the vacuum tube in air, aided by a standard photomultiplier and very fast pulse-height analyzing electronics. Due to the low dead time of all system components it can cope with the high throughput demands of a proposed combined fast neutron and dual discrete energy gamma radiography method (FNDDER). We show tests with different types of delay-line read-out anodes and present a novel pulse-height-to-time converter circuit with its potential to discriminate gamma energies for the projected FNDDER devices for an automated cargo container inspection system (ACCIS).Comment: Proceedings of FNDA 201

    A position- and time-sensitive photon-counting detector with delay-line read-out

    Get PDF
    We have developed image intensifier tubes with delay-anode read-out for time- and position-sensitive photon counting. The timing precision is better than 1 ns with 1000x1000 pixels position resolution and up to one megacounts/s processing rate. Large format detectors of 40 and 75 mm active diameter with internal helical-wire delay-line anodes have been produced and specified. A different type of 40 and 25 mm tubes with semi-conducting screen for image charge read-out allow for an economic and robust tube design and for placing the read-out anodes outside the sealed housing. Two types of external delay-line anodes, i.e. pick-up electrodes for the image charge, have been tested. We present tests of the detector and anode performance. Due to the low background this technique is well suited for applications with very low light intensity and especially if a precise time tagging for each photon is required. As an example we present the application of scintillator read-out in time-of-flight (TOF) neutron radiography. Further applications so far are Fluorescence Life-time Microscopy (FLIM) and AstronomyComment: Proceedings of SPIE Conference "Optics and Optoelectronics", 16 - 19. Apr.200

    High Spatial Resolution Fast-Neutron Imaging Detectors for Pulsed Fast-Neutron Transmission Spectroscopy

    Full text link
    Two generations of a novel detector for high-resolution transmission imaging and spectrometry of fast-neutrons are presented. These devices are based on a hydrogenous fiber scintillator screen and single- or multiple-gated intensified camera systems (ICCD). This detector is designed for energy-selective neutron radiography with nanosecond-pulsed broad-energy (1 - 10 MeV) neutron beams. Utilizing the Time-of-Flight (TOF) method, such a detector is capable of simultaneously capturing several images, each at a different neutron energy (TOF). In addition, a gamma-ray image can also be simultaneously registered, allowing combined neutron/gamma inspection of objects. This permits combining the sensitivity of the fast-neutron resonance method to low-Z elements with that of gamma radiography to high-Z materials.Comment: Also published in JINST: http://www.iop.org/EJ/abstract/1748-0221/4/05/P0501

    Advances in imaging THGEM-based detectors

    Get PDF
    The thick GEM (THGEM) [1] is an "expanded" GEM, economically produced in the PCB industry by simple drilling and etching in G-10 or other insulating materials (fig. 1). Similar to GEM, its operation is based on electron gas avalanche multiplication in sub-mm holes, resulting in very high gain and fast signals. Due to its large hole size, the THGEM is particularly efficient in transporting the electrons into and from the holes, leading to efficient single-electron detection and effective cascaded operation. The THGEM provides true pixilated radiation localization, ns signals, high gain and high rate capability. For a comprehensive summary of the THGEM properties, the reader is referred to [2, 3]. In this article we present a summary of our recent study on THGEM-based imaging, carried out with a 10x10 cm^2 double-THGEM detector.Comment: 3 pages, 3 figures. Presented at the 10th Pisa Meeting on Advanced Detectors; ELBA-Italy; May 21-27 200
    • …