26 research outputs found

    Natural history and clinical effect of aortic valve regurgitation after left ventricular assist device implantation

    Get PDF
    ObjectivesAortic valve regurgitation reduces left ventricular assist device mechanical efficiency. Evidence has also suggested that left ventricular assist device implantation can induce or exacerbate aortic valve regurgitation. However, this has not been compared with aortic valve regurgitation progression in a nonsurgical end-stage heart failure population. Furthermore, its clinical effect is unclear. We sought to characterize the development and progression of aortic valve regurgitation in left ventricular assist device recipients and to identify its clinical effect.MethodsA review of all consecutive patients who received an intracorporeal left ventricular assist device at Duke University Medical Center from January 2004 to January 2011 was conducted. Cases of previous or concomitant aortic valve surgery were excluded. Data from the remaining implants (n = 184) and a control group of contemporaneous nonsurgical patients with end-stage heart failure (n = 132) were analyzed. Serial transthoracic echocardiography was used to characterize aortic valve regurgitation as a function of time.ResultsLeft ventricular assist device implantation was associated with worsening aortic valve regurgitation, defined as an increase in aortic valve regurgitation grade, relative to the nonsurgical patients with end-stage heart failure (P < .0001). The recipients of continuous flow left ventricular assist devices were more likely than recipients of pulsatile left ventricular assist devices to develop worsening aortic valve regurgitation (P = .0348). Moderate or severe aortic valve regurgitation developed in 21 left ventricular assist device recipients; this was unrelated to the type of device implanted (continuous vs pulsatile; P = .754) or aortic valve regurgitation grade before left ventricular assist device implantation (P = .42). Five patients developed severe aortic valve regurgitation; all of whom underwent aortic valve procedures.ConclusionsNative aortic valve regurgitation developed and/or progressed after left ventricular assist device implantation, with this effect being more pronounced in continuous flow left ventricular assist device recipients. However, the preoperative aortic valve regurgitation grade failed to correlate with the development of substantial aortic valve regurgitation after left ventricular assist device implantation. After left ventricular assist device implantation, aortic valve regurgitation had a small, but discernible, clinical effect, with some patients developing severe aortic valve regurgitation and requiring aortic valve procedures. These data have implications for the long-term management of left ventricular assist device recipients, in particular as the durability of implantable continuous flow left ventricular assist device therapy improves

    Reproducibility of left atrial ablation with high-intensity focused ultrasound energy in a calf model

    Get PDF
    ObjectiveAchieving transmural tissue ablation might be necessary for successful treatment of atrial fibrillation. The purpose of this study was to evaluate the reproducibility of transmural left atrial ablation using a high-intensity focused ultrasound energy system in a calf model.MethodsNine heparinized bovines underwent a beating-heart left atrial ablation with a single application of the high-intensity focused ultrasound device. All animals were acutely killed, and the left atrium was fixed in formalin. Protocolized histological sections (5 μm) were obtained throughout each lesion and prepared with Masson trichrome and hematoxylin and eosin staining. Measurements were performed on a total of 359 slides from the 9 lesions. In addition, fresh left atrial tissues from 18 unused human donor hearts that did not meet the criteria for cardiac transplantation were measured at the site where the high-intensity focused ultrasound device is normally applied.ResultsCalf left atrial thickness ranged between 2.5 and 20.1 mm, with a mean of 9.10 mm. High-intensity focused ultrasound ablation consistently produced a 100% transmural lesion in left atrial thickness up to 6 mm. In addition, a transmural lesion was observed in 91% of tissues that were up to 10 mm thick and in 85% that were up to 15 mm thick. Human left atrial thickness ranged between 1.2 to 6 mm, with a mean of 3.7 mm.ConclusionsCalf left atrial thickness in this study was greater than human left atrial thickness. Human left atrial thickness is generally less than 6 mm, and in this range high-intensity focused ultrasound ablation achieved 100% transmurality. These histological results might correlate with a high success rate of atrial fibrillation ablation by using the high-intensity focused ultrasound system

    Twenty-five-year outcomes after multiple internal thoracic artery bypass

    Get PDF
    ObjectiveCoronary artery bypass grafting with multiple internal thoracic artery grafts is currently controversial. This study assessed single institutional outcomes with multiple internal thoracic artery grafting for guidance with future clinical decisions.MethodsIn 19,482 patients undergoing multivessel coronary artery bypass grafting (1984-2009), baseline characteristics were recorded in a prospective databank, and follow-up was obtained by questionnaires, phone contact, or National Death Index. Outcomes examined were subsequent myocardial infarction, percutaneous coronary intervention, reoperative coronary artery bypass grafting, all-cause death, and a composite of the 4. Three groups were defined: (1) no internal thoracic artery graft (1874/19,482 or 9%); (2) single internal thoracic artery grafts and adjunctive venous conduits (single internal thoracic artery; 16,881/19,482 or 87%); and (3) multiple internal thoracic artery grafts (728/19,482 or 4%). Multivariable Cox modeling adjusted for differences in baseline characteristics, and comparisons were performed using area under the curve analysis.ResultsDifferences in baseline characteristics for the no internal thoracic artery graft, single internal thoracic artery, and multiple internal thoracic artery groups were as follows: median age 66, 64, and 59 years, respectively; congestive heart failure 22%, 18%, and 13%, respectively; ejection fraction 0.50, 0.52, and 0.51, respectively; reoperation 10%, 3%, and 7%, respectively; diabetes 27%, 30%, and 15%, respectively; and female gender 33%, 28%, and 20%, respectively. No differences existed in the median number of diseased vessels (3, 3, and 3, respectively) or number of grafts per patient (3, 3, and 3, respectively). Composite outcome improved with increasing internal thoracic artery grafts, whether assessing unadjusted or risk-adjusted data. Compared with no internal thoracic artery graft, the adjusted hazard ratio was 0.79 (confidence interval, 0.74-0.83) for single internal thoracic artery grafting and 0.70 (confidence interval, 0.62-0.80) for multiple internal thoracic artery grafting (both P < .001), reducing risk by 21% and 30%, respectively.ConclusionsThis study confirms improved patient outcomes with multiple internal thoracic artery grafting, achieving half again as much benefit as single internal thoracic artery grafting alone. The data suggest that increasing application of multiple internal thoracic artery grafting should be encouraged to mitigate the inherent risks and costs of long-term cardiac events

    Adeno-Associated Viral Vectors Based on Serotype 3b Use Components of the Fibroblast Growth Factor Receptor Signaling Complex for Efficient Transduction

    Get PDF
    Adeno-associated virus type 3b (AAV3b) has been largely ignored by gene therapists because of the inability of vectors based on this serotype to transduce target tissues efficiently. Here we describe a phenomenon unique to AAV3b in that vectors based on this serotype mediate enhanced transduction in the presence of heparin. Among the many biological functions attributed to heparin, its interaction with, and ability to regulate, several growth factors (GFs) and growth factor receptors (GFRs) has been well characterized. Using GFR-overexpressing cell lines, soluble GFs and heparins, as well as specific GFR inhibitors, we have demonstrated a requirement for fibroblast growth factor receptor-2 (FGFR2) and FGF1 in the heparin-mediated augmentation of AAV3b vector transduction. In contrast to AAV2, we establish that heparin can be used as an adjunct with AAV3b to further increase transduction in a variety of cells and target tissues, additionally suggesting that AAV3b may be an attractive viral vector for clinical use during procedures in which heparin is used. In summary, AAV3b exhibits FGFR2-dependent, markedly enhanced transduction efficiency in the presence of heparin and FGFs, which could make it a useful vector for gene therapy in a variety of human diseases

    Cold Agglutinin Autoantibodies in a Patient without a Visible Coronary Sinus Ostium: Strategies for Myocardial Protection without Using Retrograde Cardioplegia

    No full text
    The presence of cold agglutinins (CA) during cardiac surgery with cardiopulmonary bypass usually creates the need for an altered surgical plan. In this case, the CA were discovered after the initiation of bypass, limiting the time, and cardioplegia solutions that could be used in the new approach. The inability to cannulate the coronary sinus with a retrograde cardioplegia catheter excluded the standard approach to myocardial preservation with CA of using continuous warm blood. For this case, we used intermittent cold crystalloid delivered via the antegrade needle for the first half of the procedure and through the saphenous vein graft anastomosis during the aortic valve portion of the cross-clamp period

    EOS® is reliable to evaluate spinopelvic parameters: a validation study

    No full text
    Abstract Background Sagittal and coronal standing radiographs have been the standard imaging for assessing spinal alignment. However, their disadvantages include distortion at the image edges and low interobserver reliability in some parameters. EOS® is a low-dose biplanar digital radiographic imaging system that can avoid distortion by obtaining high-definition images. Methods This study aimed to evaluate spinopelvic parameters in conventional lateral C1S1 upright radiographs and EOS® images and compare them. Patients with non-deformity changes were subjected to routine clinical examinations. Plain AP and lateral X-ray radiographs were obtained along the entire spine length. Patients were also referred for full-length EOS® of the spine. Thoracic Kyphosis (TK), Lumbar Lordosis (LL), Pelvic Tilt (PT), Sacral Slope (SS), Pelvic Incidence (PI), and Sagittal Vertical Axis (SVA) were measured in the two studies by an orthopedic surgeon and a radiologist using PACS software. Also, the orthopedic surgeon evaluated the studies again after two weeks. Intra- and inter-observer reliability was then assessed using the interclass correlation coefficient (ICC). Also, the coefficient of variation was used to assess intra- and inter-observer reliability. Bland-Altman plots were drawn for each parameter. Results The mean age was 48.2 ± 6.6 years. Among the 50 patients, 30 (60%) were female. The mean ICC for TK, LL, PT, SS, PI, and SVA in EOS® images are 0.95, 0.95, 0.92, 0.90, 0.94, and 0.98, respectively, and in C1S1 radiography images, it was 0.92, 0.87, 0.94, 0.88, 0.93, and 0.98, respectively which shows good to excellent results. The coefficient of variation for intraobserver reliability was relatively low (< 18.6%), while it showed higher percentages in evaluating interobserver reliability (< 54.5%). Also, the Bland-Altman plot showed good agreement for each parameter. Conclusion Spinopelvic parameters, e.g., TK, LL, SS, PI, and SS, in EOS® are reliable and comparable to those in conventional lateral upright C1S1 radiographs

    Outcomes After Implantable Left Ventricular Assist Device Replacement Procedures

    No full text
    As the duration of support increases for patients with continuous flow left ventricular assist devices (LVADs), device replacement may still be necessary for a variety of indications. Outcomes after replacement LVAD surgeries have not been extensively described, and whether these patients experience outcomes similar to primary LVAD implant patients remains unclear. From 2003 to 2012, 342 consecutive implantable LVAD procedures took place at a single institution, of which 201 were considered destination therapy. Within this larger group, 30 patients underwent 35 replacement procedures. The three major indications for replacement LVAD procedures were mechanical/electrical failure (57%), hemolysis/thrombosis (29%), and infection (14%). Propensity matching using preoperative characteristics was used to generate a primary implant control group to determine the impact of the replacement status on outcomes. Thirty-day and 1-year survival after LVAD replacement was 90% and 48%, respectively. Survival outcomes were worse for patients undergoing device replacement compared with the matched primary cohort (p = 0.03). The need for transfusion and the incidence of postoperative right ventricular and renal dysfunction were similar between the two groups, as was length of hospitalization. There was no difference between the rates of postoperative infection or stroke. Emergent replacement procedures had a higher mortality than those done nonemergently. Given these findings, earlier timing for replacement, temporary stabilization with an extracorporeal device, and use of a nonsternotomy surgical approach should be investigated as strategies to improve outcomes
    corecore