8 research outputs found

    Journal of Cardiovascular Magnetic Resonance

    No full text
    Poster presentation Myocardial delayed enhancement using parallel imaging with an overlapping partial-Fourier acquisition and variable k-space segmentatio

    High resolution multi-arterial phase MRI improves lesion contrast in chronic liver disease

    No full text
    Purpose: To determine the reliability of arterial phase capture and evaluate hypervascular lesion contrast kinetics with a combined view-sharing and parallel imaging dynamic contrast-enhanced acquisition, DIfferential Sub-sampling with Cartesian Ordering (DISCO), in patients with known chronic liver disease. Methods: A retrospective review of 3T MR images from 26 patients with known chronic liver disease referred for hepatocellular carcinoma surveillance or post-treatment follow up was performed. After administration of a gadolinium-based contrast agent, a multiphasic acquisition was obtained in a 28 s breath-hold, from which seven sequential post-contrast image volumes were reconstructed. Results: The late arterial phase was successfully captured in all cases (26/26, 95% CI 87-100%). Images obtained 26 s post-injection had the highest frequency of late arterial phase capture (20/26) and lesion detection (23/26) of any individual post-contrast time; however, the multiphasic data resulted in a significantly higher frequency of late arterial phase capture (26/26, p=0.03) and a higher relative contrast (5.37+/-0.97 versus 7.10+/-0.98, p < 0.01). Conclusion: Multiphasic acquisition with combined view-sharing and parallel imaging reliably captures the late arterial phase and provides sufficient temporal resolution to characterize hepatic lesion contrast kinetics in patients with chronic liver disease while maintaining high spatial resolution

    Accurate and objective infarct sizing by contrast-enhanced magnetic resonance imaging in a canine myocardial infarction model.

    Get PDF
    To identify an accurate and reproducible method to define myocardial infarct (MI) size, we conducted a study in a closed-chest canine model of acute myocardial infarction, in which MI size was measured using different thresholding techniques and by imaging at different delay times after contrast administration

    Evaluation of a New, Highly Flexible Radiofrequency Coil for MR Simulation of Patients Undergoing External Beam Radiation Therapy

    No full text
    Purpose: To evaluate the performance of a new, highly flexible radiofrequency (RF) coil system for imaging patients undergoing MR simulation. Methods: Volumetric phantom and in vivo images were acquired with a commercially available and prototype RF coil set. Phantom evaluation was performed using a silicone-filled humanoid phantom of the head and shoulders. In vivo assessment was performed in five healthy and six patient subjects. Phantom data included T1-weighted volumetric imaging, while in vivo acquisitions included both T1- and T2-weighted volumetric imaging. Signal to noise ratio (SNR) and uniformity metrics were calculated in the phantom data, while SNR values were calculated in vivo. Statistical significance was tested by means of a non-parametric analysis of variance test. Results: At a threshold of p = 0.05, differences in measured SNR distributions within the entire phantom volume were statistically different in two of the three paired coil set comparisons. Differences in per slice average SNR between the two coil sets were all statistically significant, as well as differences in per slice image uniformity. For patients, SNRs within the entire imaging volume were statistically significantly different in four of the nine comparisons and seven of the nine comparisons performed on the per slice average SNR values. For healthy subjects, SNRs within the entire imaging volume were statistically significantly different in seven of the nine comparisons and eight of the nine comparisons when per slice average SNR was tested. Conclusions: Phantom and in vivo results demonstrate that image quality obtained from the novel flexible RF coil set was similar or improved over the conventional coil system. The results also demonstrate that image quality is impacted by the specific coil configurations used for imaging and should be matched appropriately to the anatomic site imaged to ensure optimal and reproducible image quality
    corecore