15,313 research outputs found

    Environmental aspects of soil phosphorus testing

    Get PDF
    peer-reviewedSoil phosphorus testing in Ireland uses Morgan’s reagent from samples taken to 10 cm depth for agronomic recommendations. However, its suitability as an environmental indicator has been questioned in terms of sample depth and extraction solution. Seven grassland sites were sampled to depths of 2, 5 and 10 cm and extracted for Morgan’s P, the standard agronomic test, as well as iron-oxide impregnated paper strip P (FeOP), calcium chloride extractable P (CaCl2-P) and water soluble P (WSP), all proposed as environmental soil tests. Extractable soil P decreased with increasing sample depth, as did variances in each test, such that, 2 cm samples had highest concentrations and variances. The current standard sample depth (10 cm) was linearly related to corresponding data from samples taken to 2 and 5 cm, indicating that surface soil P can be consistently estimated from the current standard depth. When soil tests were compared with dissolved reactive P (DRP) in overland flow collected from two field sites, certain soil tests were better indicators of P loss than others. The relative difference in Morgan’s P values at the standard sample depth (10 cm) was reflected in the relative difference in P loss between the two sites. Average values of DRP collected from two sites ranged from 0.032 to 0.067 mg/l at the low P site and 0.261 to 0.620 at the high P site. Average DRP values from the high P site and maximum DRP values from the low P site were simulated using water-soluble P extraction at water to soil ratios 5 to 250 l/kg. In this study, Morgan’s P to 10 cm gave a good indication of the relative difference in DRP loss between the two sites

    An empirical study evaluating depth of inheritance on the maintainability of object-oriented software

    Get PDF
    This empirical research was undertaken as part of a multi-method programme of research to investigate unsupported claims made of object-oriented technology. A series of subject-based laboratory experiments, including an internal replication, tested the effect of inheritance depth on the maintainability of object-oriented software. Subjects were timed performing identical maintenance tasks on object-oriented software with a hierarchy of three levels of inheritance depth and equivalent object-based software with no inheritance. This was then replicated with more experienced subjects. In a second experiment of similar design, subjects were timed performing identical maintenance tasks on object-oriented software with a hierarchy of five levels of inheritance depth and the equivalent object-based software. The collected data showed that subjects maintaining object-oriented software with three levels of inheritance depth performed the maintenance tasks significantly quicker than those maintaining equivalent object-based software with no inheritance. In contrast, subjects maintaining the object-oriented software with five levels of inheritance depth took longer, on average, than the subjects maintaining the equivalent object-based software (although statistical significance was not obtained). Subjects' source code solutions and debriefing questionnaires provided some evidence suggesting subjects began to experience diffculties with the deeper inheritance hierarchy. It is not at all obvious that object-oriented software is going to be more maintainable in the long run. These findings are sufficiently important that attempts to verify the results should be made by independent researchers

    Thrombotic variables and risk of idiopathic venous thromboembolism in women aged 45-64 years - Relationships to hormone replacement therapy

    Get PDF
    Hormone replacement therapy (HRT) has been shown to increase the relative risk of idiopathic venous thromboembolism (VTE) about threefold in several observational studies and one randomised controlled trial. Whether or not this relative risk is higher in women with underlying thrombophilia phenotypes, such as activated protein C (APC) resistance, is unknown. We therefore restudied the participants in a case-control study of the relationship between the use of HRT and the occurrence of idiopathic VTE in women aged 45-64 years. After protocol exclusions, 66 of the cases in the original study and 163 of the controls were studied. Twenty haematological variables relevant to risk of VTE were analysed, including thrombotic states defined from the literature. The relative risk of VTE showed significant associations with APC resistance (OR 4.06; 95% CI 1.62, 10.21); low antithrombin (3.33; 1.15, 9.65) or protein C (2.93; 1.06, 8.14); and high coagulation factor IX (2.34: 1.26, 1.35), or fibrin D-dimer (3.84; 1.99, 7.32). HRT use increased the risk of VTE in women without any of these thrombotic static; (OR 4.09; 95% CI 1.26, 13.30). A similar effect of HRT use on the relative risk of VTE was also found in women with prothrombotic states. Thus for example, the combination of HRT use and APC resistance increased the risk of VTE about 13-fold compared with women of similar age without either APC resistance or HRT use (OR 13.27; 95%, CI 4.30, 40.97). We conclude that the combination of HRT use and thrombophilias (especially if multiple) increases the relative risk of VTE substantially; hence women known to have thrombophilias (especially if multiple) should be counselled about this increased risk prior to prescription of HRT. However. HRT increases the risk of VTE about fourfold even in women without any thrombotic abnormalities: possible causes are discussed

    The Mississippi River and Prairie Du Chien, Wisconsin

    Get PDF

    Direct Determinations of the Redshift Behavior of the Pressure, Energy Density, and Equation of State of the Dark Energy and the Acceleration of the Universe

    Full text link
    One of the goals of current cosmological studies is the determination of the expansion and acceleration rates of the universe as functions of redshift, and the determination of the properties of the dark energy that can explain these observations. Here the expansion and acceleration rates are determined directly from the data, without the need for the specification of a theory of gravity, and without adopting an a priori parameterization of the form or redshift evolution of the dark energy. We use the latest set of distances to SN standard candles from Riess et al. (2004), supplemented by data on radio galaxy standard ruler sizes, as described by Daly and Djorgovski (2003, 2004). We find that the universe transitions from acceleration to deceleration at a redshift of about 0.4. The standard "concordance model" provides a reasonably good fit to the dimensionless expansion rate as a function of redshift, though it fits the dimensionless acceleration rate as a function of redshift less well. The expansion and acceleration rates are then combined with a theory of gravity to determine the pressure, energy density, and equation of state of the dark energy as functions of redshift. Adopting General Relativity as the correct theory of gravity, the redshift trends for the pressure, energy density, and equation of state of the dark energy out to redshifts of about one are determined, and are found to be generally consistent with the concordance model.Comment: 8 pages, 5 figures. Invited presentation at Coral Gables 200

    Dry Friction due to Adsorbed Molecules

    Full text link
    Using an adiabatic approximation method, which searches for Tomlinson model-like instabilities for a simple but still realistic model for two crystalline surfaces in the extremely light contact limit, with mobile molecules present at the interface, sliding relative to each other, we are able to account for the virtually universal occurrence of "dry friction." The model makes important predictions for the dependence of friction on the strength of the interaction of each surface with the mobile molecules.Comment: four pages of latex, figure provide

    A rapid and multi-element method for the analysis of major nutrients in grass (Lolium perenne) using energy-dispersive X-ray fluorescence spectroscopy

    Get PDF
    peer-reviewedElemental analysis of grass (Lolium perenne) is essential in agriculture to ensure grass quality and animal health. Energy-dispersive X-ray fluorescence (EDXRF) spectroscopy is a rapid, multi-element alternative to current methods using acid digestion and inductively coupled plasma optical emission spectrometry (ICP-OES). Percentage phosphorus (P), potassium (K), magnesium (Mg) and calcium (Ca), determined from grass samples using EDXRF, were within 0.035, 0.319, 0.025 and 0.061, respectively, of ICP-OES values. Concordance correlation coefficients computed using agreement statistics ranged from 0.4379 to 0.9669 (values close to one indicate excellent agreement); however, the level of agreement for each element depended on the calibrations used in EDXRF. Empirical calibrations gave excellent agreement for percentage P, K and Ca, but moderate agreement for percentage Mg due to a weaker correlation between standards and intensities. Standardless calibration using the fundamental parameters (FP) approach exhibited bias, with consistently lower values reported for percentage P and Mg, when compared with ICP-OES methods. The relationship between the methods was plotted as scatter plots with the line of equality included, and although correlation coefficients indicated strong relationships, these statistics masked the effects of consistent bias in the data for percentage P and Mg. These results highlight the importance of distinguishing agreement from correlation when using statistical methods to compare methods of analysis. Agreement estimates improved when a matching library of grass samples was added to the FP method. EDXRF is a comparable alternative to conventional methods for grass analysis when samples of similar matrix type are used as empirical standards or as a matching library

    The Delineation of Accountants\u27 Legal Liability to Third Parties: Bily and Beyond

    Get PDF
    • …
    corecore