3,379 research outputs found

    An Eccentric Hot Jupiter Orbiting the Subgiant HD 185269

    Get PDF
    We report the detection of a Jupiter-mass planet in a 6.838 day orbit around the 1.28 solar mass subgiant HD 185269. The eccentricity of HD 185269b (e = 0.30) is unusually large compared to other planets within 0.1 AU of their stars. Photometric observations demonstrate that the star is constant to +/-0.0001 mag on the radial velocity period, strengthening our interpretation of a planetary companion. This planet was detected as part of our radial velocity survey of evolved stars located on the subgiant branch of the H-R diagram--also known as the Hertzsprung Gap. These stars, which have masses between 1.2 and 2.5 solar masses, play an important role in the investigation of the frequency of extrasolar planets as a function of stellar mass.Comment: 18 pages, 4 figures, 3 tables, ApJ in press (scheduled for Dec 2006, v652n2

    Removing Barriers to Tecovirimat for Mpox-infected Individuals via Novel Models of Care Delivery

    Get PDF
    Problem Statement During the 2022 mpox outbreak, the CDC’s expanded access Investigational New Drug (IND) protocol created a practical barrier to the outpatient provision of tecovirimat. We rapidly implemented a tecovirimat prescription program for individuals infected with mpox to improves access to care. Project AIM Primary aim: describe how we rapidly implemented a program for increasing tecovirimat distribution in a metropolitan area. Secondary aims: describe the patient population who received tecovirimat as treatment for mpox at our clinic and analyze several clinically relevant time intervals along the continuum of care delivery.https://jdc.jefferson.edu/didemposters/1004/thumbnail.jp

    Comparison of CDMS [100] and [111] oriented germanium detectors

    Full text link
    The Cryogenic Dark Matter Search (CDMS) utilizes large mass, 3" diameter ×\times 1" thick target masses as particle detectors. The target is instrumented with both phonon and ionization sensors and comparison of energy in each channel provides event-by-event classification of electron and nuclear recoils. Fiducial volume is determined by the ability to obtain good phonon and ionization signal at a particular location. Due to electronic band structure in germanium, electron mass is described by an anisotropic tensor with heavy mass aligned along the symmetry axis defined by the [111] Miller index (L valley), resulting in large lateral component to the transport. The spatial distribution of electrons varies significantly for detectors which have their longitudinal axis orientations described by either the [100] or [111] Miller indices. Electric fields with large fringing component at high detector radius also affect the spatial distribution of electrons and holes. Both effects are studied in a 3 dimensional Monte Carlo and the impact on fiducial volume is discussed.Comment: Low Temperature Detector 14 conference proceedings to be published in the Journal of Low Temperature Physic

    Validation of Phonon Physics in the CDMS Detector Monte Carlo

    Get PDF
    The SuperCDMS collaboration is a dark matter search effort aimed at detecting the scattering of WIMP dark matter from nuclei in cryogenic germanium targets. The CDMS Detector Monte Carlo (CDMS-DMC) is a simulation tool aimed at achieving a deeper understanding of the performance of the SuperCDMS detectors and aiding the dark matter search analysis. We present results from validation of the phonon physics described in the CDMS-DMC and outline work towards utilizing it in future WIMP search analyses.Comment: 6 Pages, 5 Figures, Proceedings of Low Temperature Detectors 14 Conferenc

    Filariasis in Travelers Presenting to the GeoSentinel Surveillance Network

    Get PDF
    As international travel increases, there is rising exposure to many pathogens not traditionally encountered in the resource-rich countries of the world. The GeoSentinel Surveillance Network, a global network of medicine/travel clinics, was established in 1995 to detect morbidity trends among travelers. Filarial infections (parasitic worm infections that cause, among others, onchocerciasis [river blindness], lymphatic filariasis [e.g. elephantiasis, lymphedema, hydrocele] and loiasis [African eyeworm]) comprised 0.62% (n = 271) of the 43,722 medical conditions reported to the GeoSentinel Network between 1995 and 2004. Immigrants from filarial-endemic regions comprised the group most likely to have acquired a filarial infection; sub-Saharan Africa was the region of the world where the majority of filarial infections were acquired. Long-term travel (greater than 1 month) was more likely to be associated with acquisition of one of the filarial infections than shorter-term travel

    Phonon Quasidiffusion in Cryogenic Dark Matter Search Large Germanium Detectors

    Get PDF
    We present results on quasidi usion studies in large, 3 inch diameter, 1 inch thick [100] high purity germanium crystals, cooled to 50 mK in the vacuum of a dilution refrigerator, and exposed with 59.5 keV gamma-rays from an Am-241 calibration source. We compare data obtained in two di erent detector types, with di erent phonon sensor area coverage, with results from a Monte Carlo. The Monte Carlo includes phonon quasidi usion and the generation of phonons created by charge carriers as they are drifted across the detector by ionization readout channels.United States. Dept. of Energy (Grant DE-FG02-04ER41295)United States. Dept. of Energy (Grant DE-FG02-07ER41480)National Science Foundation (U.S.) (Grant PHY-0542066)National Science Foundation (U.S.) (Grant PHY-0503729)National Science Foundation (U.S.) (Grant PHY-0503629)National Science Foundation (U.S.) (Grant PHY-0504224)National Science Foundation (U.S.) (Grant PHY-0705078)National Science Foundation (U.S.) (Grant PHY-0801712

    Results from a Low-Energy Analysis of the CDMS II Germanium Data

    Get PDF
    We report results from a reanalysis of data from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken between October 2006 and September 2008 using eight germanium detectors are reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased sensitivity to interactions from Weakly Interacting Massive Particles (WIMPs) with masses below ~10 GeV/c^2. This analysis provides stronger constraints than previous CDMS II results for WIMP masses below 9 GeV/c^2 and excludes parameter space associated with possible low-mass WIMP signals from the DAMA/LIBRA and CoGeNT experiments.Comment: 9 pages, 8 figures. Supplemental material included as ancillary files. v3) Added appendix with additional details regarding energy scale and background

    Search for inelastic dark matter with the CDMS II experiment

    Get PDF
    Results are presented from a reanalysis of the entire five-tower data set acquired with the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory, with an exposure of 969 kg-days. The analysis window was extended to a recoil energy of 150 keV, and an improved surface-event background-rejection cut was defined to increase the sensitivity of the experiment to the inelastic dark matter (iDM) model. Three dark matter candidates were found between 25 keV and 150 keV. The probability to observe three or more background events in this energy range is 11%. Because of the occurrence of these events the constraints on the iDM parameter space are slightly less stringent than those from our previous analysis, which used an energy window of 10-100 keV.Comment: 10 pages, 10 figures, minor changes to match published version, conclusion unchange

    Needle stick injuries among dental students: risk factors and recommendations for prevention

    Get PDF
    Aim: To evaluate the risk factors of needle stick injuries (NSIs) sustained by undergraduate dental students and nurse students at the King's College London (KCL) Dental Institute. Materials and methods: A retrospective study evaluated the incident reports relating to NSIs reported over a period of 2 years. Factors including the dental department, study year, and when the injury took place during administration of local anaesthesia (LA) and recapping conventional syringe or clearing work surface or during disposal. Results: This report showed that students are at the highest risk of NSIs at the fourth year of their 5-year BDS course. About one-third of injuries were reported among this group of students followed by year 5 students (25%). Oral surgery clinics were the major source of incident reporting when compared with other specialised dental clinics within the institute. The left hands of the students were the most frequently affected by such injuries and then the right hands of student dental nurses. The attempt of needle recapping of conventional syringes was the least reported mechanism of injuries and constituted only 15% of the total injuries and mainly occurred in third year students. The most frequent injuries among student nurses were during disposal of the needle. Conclusion: Less NSIs occur when using safety syringes. A non-recapping policy with immediate disposal of either the conventional or safety syringe systems after injection would prevent all clearance-related NSIs sustained by nurses. To avoid NSIs, education plays a vital role particularly with effective implementation of the change to safety syringes with appropriate training
    corecore