58 research outputs found

    Study of Flare Assessment in Systemic Lupus Erythematosus Based on Paper Patients.

    Get PDF
    OBJECTIVE: To determine the level of agreement of disease flare severity (distinguishing severe, moderate, and mild flare and persistent disease activity) in a large paper-patient exercise involving 988 individual cases of systemic lupus erythematosus. METHODS: A total of 988 individual lupus case histories were assessed by 3 individual physicians. Complete agreement about the degree of flare (or persistent disease activity) was obtained in 451 cases (46%), and these provided the reference standard for the second part of the study. This component used 3 flare activity instruments (the British Isles Lupus Assessment Group [BILAG] 2004, Safety of Estrogens in Lupus Erythematosus National Assessment [SELENA] flare index [SFI] and the revised SELENA flare index [rSFI]). The 451 patient case histories were distributed to 18 pairs of physicians, carefully randomized in a manner designed to ensure a fair case mix and equal distribution of flare according to severity. RESULTS: The 3-physician assessment of flare matched the level of flare using the 3 indices, with 67% for BILAG 2004, 72% for SFI, and 70% for rSFI. The corresponding weighted kappa coefficients for each instrument were 0.82, 0.59, and 0.74, respectively. We undertook a detailed analysis of the discrepant cases and several factors emerged, including a tendency to score moderate flares as severe and persistent activity as flare, especially when the SFI and rSFI instruments were used. Overscoring was also driven by scoring treatment change as flare, even if there were no new or worsening clinical features. CONCLUSION: Given the complexity of assessing lupus flare, we were encouraged by the overall results reported. However, the problem of capturing lupus flare accurately is not completely solved

    Metal stents: a bridge to surgery in hilar cholangiocarcinoma

    Get PDF
    Background Obstructive jaundice in patients with hilar cholangiocarcinoma is a known risk factor for hepatic failure after liver resection. Plastic stents are most widely used for preoperative drainage. However, plastic stents are known to have limited patency time and therefore, in palliative settings, the self-expanding metal stent (SEMS) is used. This type of stent has been shown to be superior because it allows for rapid biliary decompression and a reduced complication rate after insertion. This study explores the use of the SEMS for biliary decompression in patients with operable hilar cholangiocarcinoma. Methods A retrospective evaluation of a prospectively maintained database at a tertiary hepatobiliary referral centre was carried out. All patients with resectable cholangiocarcinoma were recorded. Results Of 260 patients referred to this unit with cholangiocarcinoma between January 2008 and April 2012, 50 patients presented with operable cholangiocarcinoma and 27 of these had obstructive jaundice requiring stenting. Ten patients were initially treated with SEMSs; no stent failure occurred in these patients. Seventeen patients initially received plastic stents, seven of which failed in the interval between stent placement and laparotomy. These stents were replaced by SEMSs in four patients and by plastic stents in three patients. Median time to laparotomy was 45 days and 68 days in patients with SEMSs and plastic stents, respectively. Conclusions Self-expanding metal stents provide adequate and rapid biliary drainage in patients with obstruction caused by hilar cholangiocarcinoma. No re-interventions were required. This probably reflects the relatively short interval between stent placement and laparotomy
    • …
    corecore