20 research outputs found

    Reoperations after first lumbar disc herniation surgery; a special interest on residives during a 5-year follow-up

    Get PDF
    BACKGROUND: The overall rate of operations after recurrent lumbar disc herniation has been shown to be 3–11%. However, little is known about the rate of residives. Thus the aim of this study was to explore the cumulative rates of re-operations and especially residive disc herniations at the same side and level as the primary disc herniation after first lumbar disc herniation surgery and the factors that influence the risk of re-operations over a five year follow-up study. METHODS: 166 virgin lumbar disc herniation patients (mean age 42 years, 57% males) were studied. Data on patients' initial disc operations and type and timing of re-operations during the follow-up were collected from patient files. Back and leg pain on visual analog scale and employment status were collected by questionnaires. RESULTS: The cumulative rate of re-operations for lumbar disc herniation was 10.2% (95% Cl 6.0 to 15.1). The rate of residives at initial site was 7.4% (95% Cl 3.7 to 11.3) and rate of lumbar disc herniations at other sites was 3.1% (95% Cl 0.6 to 6.2). The occurrence of residive lumbar disc herniations was evenly distributed across the 5 years. Neither age, gender, preoperative symptoms, physical activity nor employment had effect on the probability of re-operation. CONCLUSION: Seven percent of the lumbar disc patients had a residive lumbar disc operation within five years of their first operation. No specific factors influencing the risk for re-operation were found

    Do large femoral heads reduce the risks of impingement in total hip arthroplasty with optimal and non-optimal cup positioning?

    No full text
    The purpose of this study was to assess whether large femoral heads (36–38 mm) improve the range of motion in total hip arthroplasty compared to standard (28–32 mm) femoral heads in the presence of optimal and non-optimal cup positioning. A mathematical model of the hip joint was generated by using a laser scan of a dried cadaveric hip. The range of motion was assessed with a cup inclination and anteversion of reference and with non-optimal cup positions. Large femoral heads increased the range of motion, compared to the 28-mm femoral head, in the presence of a hip prosthesis correctly implanted and even more so in the presence of non-optimal cup positioning. However, with respect to the 32-mm femoral head, large femoral heads showed limited benefits both in the presence of optimal and non-optimal cup positioning
    corecore