8 research outputs found

    ETUDE DES SUPERMODES DANS UN MICROLASER REALISE AVEC UN MIROIR DIFFRACTIF

    No full text
    GRENOBLE1-BU Sciences (384212103) / SudocSudocFranceF

    Dynamique de couplage et formation de structures dans les lasers Ă  absorbant saturable

    No full text
    Le couplage d'oscillateurs non lineaires et la formation de structures spatiales sont deux domaines particulierement importants de l'etude de la dynamique non lineaire des systemes optiques. C'est dans ce contexte que s'inscrit ce travail de these. La premiere partie est consacree a l'etude experimentale du couplage de deux lasers co 2 monomode partageant un meme absorbant saturable. La forte non linearite de l'absorbant et le caractere impulsionnel de certains regimes du systeme donnent naissance a une dynamique de couplage localise dans le temps. Les phenomenes de synchronisation des impulsions de chaque laser ainsi que la perturbation des regimes d'un laser par les impulsions de l'autre sont analyses. En ce qui concerne les regimes non impulsionnels, le couplage non localise intervient dans la synchronisation de regimes quasiperiodiques et chaotiques.L'extension au cas bimode transverse se traduit par l'apparition d'une dynamique d'antiphase. Les simulations numeriques effectuees reproduisent les regimes dynamiques observes et mettent en evidence de nouvelles bifurcations introduites par le couplage. La deuxieme partie presente une etude theorique et numerique du comportement spatio-temporel d'un laser a absorbant saturable. L'analyse de stabilite lineaire de la solution nulle montre que l'absorbant controle la longueur d'onde critique des modes qui se destabilisent au seuil. La creation ou l'inhibition des structures est analysee suivant l'ecart en frequence de l'absorbant. Une analyse faiblement non lineaire au seuil montre que le systeme est decrit par une equation de swift-hohenberg. Les simulations numeriques mettent en evidence des solutions a ondes progressives, a ondes stationnaires et en echiquier. Enfin, les simulations sur le systeme complet permettent de verifier la validite du modele de swift-hohenberg tout en donnant aussi des regimes plus fortement non lineaires, comme des impulsions 2d progressives.LILLE1-BU (590092102) / SudocSudocFranceF

    Les lasers: cours et exercices corrigés

    No full text
    Cet ouvrage présente de manière aussi simple et pédagogique que possible les fondements de la physique des lasers. Les premiers chapitres abordent la théorie des lasers, de façon progressive depuis les concepts de base (amplification lumineuse et modélisation, théorie des faisceaux gaussiens, cavités lasers) jusqu'à la théorie semi©classique. Ils sont suivis d'une description des principaux lasers d'utilisation courante et d'une introduction à l'optique non linéaire. L'ouvrage se termine par un aperçu des principales applications faisant appel aux lasers. Chaque chapitre offre deux niveaux de lecture : un texte de base suivi de compléments qui détaillent certains points ou qui abordent des questions plus spécialisées, et se termine par une série d'exercices, dont les corrigés figurent à la fin du livre

    Observation of undamped pulsations in a low-pressure, far-infrared laser and comparison with a simple theoretical model

    No full text
    Experimental details of undamped pulsations are presented for a low pressure, far-infrared (FIR) laser optically pumped by a single-frequency CO2 laser in a standing-wave configuration for both the pumping and the FIR lasing action. Spontaneous pulsing in the single-mode HCOOH FIR laser at 742 /im was observed when the cavity was tuned to the FIR resonance and when the CO2 laser of high intensity was sufficiently detuned from the resonance of the pump transition to excite two distinct velocity groups of molecules to contribute to the FIR gain. Theoretical results, based on studies of a model for a laser with two distinct resonant species forming the gain medium, providea basis for understanding the origin of these instabilities. The model compares satisfactorily with the observed FIR instabilities including the variations in pulsing frequencies observed experimentally as the CO2 laser is detuned. Additional predictions from the model include details of transitions from cw to pulsing behavior and thresholds fr deterministic chaos that may be tested in future experiments. © 1985 Optical Society of America.SCOPUS: ar.jinfo:eu-repo/semantics/publishe

    Tinea Capitis in Brussels

    No full text
    info:eu-repo/semantics/nonPublishe

    Tinea Capitis in Brussels: Epidemiology in 2013

    No full text
    info:eu-repo/semantics/nonPublishe

    Comparison of sirolimus eluting stent with bioresorbable polymer to everolimus eluting stent with permanent polymer in bifurcation lesions: Results from CENTURY II trial.

    No full text
    OBJECTIVE: To demonstrate the safety and efficacy of a new sirolimus eluting stent with bioresorbable polymer, Ultimaster, (BP-SES) compared with everolimus-eluting, permanent polymer, Xience stent (PP-EES) in bifurcation lesions with respect to the freedom from Target Lesion Failure at 1-year. METHODS: Within 1,119 patients enrolled in the CENTURY II randomized controlled multicenter trial, 194 patients were treated for bifurcation lesions and randomized to either BP-SES (n = 95) or PP-EES (n = 99). The primary endpoint was freedom from target lesion failure (TLF) composite endpoint [cardiac death, MI not clearly attributable to a non-target vessel, and clinically driven target lesion revascularization (TLR)] at 1-year. RESULTS: Baseline patient demographic, angiographic, and stenting characteristics were similar in both study arms. A single stent technique with provisional or "cross over" stenting were the most widely used in both arms (93.2% BP-SES vs. 92.4% PP-EES). Freedom from TLF at 1-year was 94.7% for BP-SES and 91.9% for PP-EES (P for noninferiority 0.031). The rate of clinically driven target lesion revascularization (TLR) at 1-year was 3.2% for BP-SES and 3.0% for PP-EES (P = 0.95). There were no significant differences detected in any of the individual clinical endpoints or other secondary clinical endpoints between the study arms at 1-year follow up. CONCLUSIONS: The new bioresorbable polymer sirolimus-eluting stent showed safety and efficacy profiles similar to durable polymer everolimus-eluting in the treatment of patients with bifurcation lesions at 1-year follow up. © 2015 Wiley Periodicals, Inc
    corecore