14 research outputs found

    Assessment of flatness and symmetry of megavoltage x-ray beam with an electronic portal imaging device (EPID)

    Get PDF
    Copyright 漏 2002 ACPSEM. All rights reserved. The document attached has been archived with permission from the publisher.The input/output characteristics of the Wellhofer BIS 710 electronic portal imaging device (EPID) have been investigated to establish its efficacy for periodic quality assurance (QA) applications. Calibration curves have been determined for the energy fluence incident on the detector versus the pixel values. The effect of the charge coupled device (CCD) camera sampling time and beam parameters (such as beam field size, dose rate, photon energy) on the calibration have been investigated for a region of interest (ROI) around the central beam axis. The results demonstrate that the pixel output is a linear function of the incident exposure, as expected for a video-based electronic portal imaging system. The field size effects of the BIS 710 are similar to that of an ion chamber for smaller field sizes up to 10 x 10 cm2. However, for larger field sizes the pixel value increases more rapidly. Furthermore, the system is slightly sensitive to dose rate and is also energy dependent. The BIS 710 has been used in the current study to develop a QA procedure for measurements of flatness and symmetry of a linac x-ray beam. As a two-dimensional image of the radiation field is obtained from a single exposure of the BIS 710, a technique has been developed to calculate flatness and symmetry from a defined radiation area. The flatness and symmetry values obtained are different from those calculated conventionally from major axes only (inplane, crossplane). This demonstrates that the technique can pick up the "cold" and "hot" spots in the analysed area, providing thus more information about the radiation beam. When calibrated against the water tank measurements, the BIS 710 can be used as a secondary device to monitor the x-ray beam flatness and symmetry.G. Liu, T. van Doorn and E. Beza

    Readout-segmented echo-planar diffusion-weighted imaging improves geometric performance for image-guided radiation therapy of pelvic tumors

    No full text
    Background and purpose: Diffusion-weighted imaging using echo-planar imaging (EPI) is prone to geometric inaccuracy, which may limit application to image-guided radiation therapy planning, as well as for voxel-based quantitative multi-parametric or multi-modal approaches. This research investigates pelvic applications at 3 T of a standard single-shot (ssEPI) and a prototype readout-segmented (rsEPI) technique. Materials and methods: Apparent diffusion coefficient (ADC) accuracy and geometric performance of rsEPI and ssEPI were compared using phantoms, and in vivo, involving 8 patients prior to MR-guided brachytherapy for locally advanced cervical cancer, and 19 patients with prostate cancer planned for tumor-targeted radiotherapy. Global and local deviations in geometric performance were tested using Dice Similarity Coefficients (DC) and Hausdorff Distances (HD). Results: In cervix patients, DC increased from 0.76 +/- 0.14 to 0.91 +/- 0.05 for the high risk clinical target volume, and 0.62 +/- 0.26 to 0.85 +/- 0.08 for the gross tumor target volume. Tumors in the peripheral zone of the prostate gland were partly projected erroneously outside of the posterior anatomic boundary of the gland by 3.1 +/- 1.6 mm in 11 of 19 patients using ADC-ssEPI but not with ADC-rsEPI. Conclusions: Both cervix and prostate ssEPI are prone to clinically relevant geometric distortions at 3 T. rsEPI provides improved geometric performance without post-processing

    The transformation of radiation oncology using real-time magnetic resonance guidance: A review

    No full text
    Radiation therapy (RT) is an essential component of effective cancer care and is used across nearly all cancer types. The delivery of RT is becoming more precise through rapid advances in both computing and imaging. The direct integration of magnetic resonance imaging (MRI) with linear accelerators represents an exciting development with the potential to dramatically impact cancer research and treatment. These impacts extend beyond improved imaging and dose deposition. Real-time MRI-guided RT is actively transforming the work flows and capabilities of virtually every aspect of RT. It has the opportunity to change entirely the delivery methods and response assessments of numerous malignancies. This review intends to approach the topic of MRI-based RT guidance from a vendor neutral and international perspective. It also aims to provide an introduction to this topic targeted towards oncologists without a speciality focus in RT. Speciality implications, areas for physician education and research opportunities are identified as they are associated with MRI-guided RT. The uniquely disruptive implications of MRI-guided RT are discussed and placed in context. We further aim to describe and outline important future changes to the speciality of radiation oncology that will occur with MRI-guided RT. The impacts on RT caused by MRI guidance include target identification, RT planning, quality assurance, treatment delivery, training, clinical workflow, tumour response assessment and treatment scheduling. In addition, entirely novel research areas that may be enabled by MRI guidance are identified for future investigation
    corecore