Outcomes of non-invasive diagnostic modalities for the detection of coronary artery disease: network meta-analysis of diagnostic randomised controlled trials
Objective: To evaluate differences in downstream testing, coronary revascularisation, and clinical outcomes following non-invasive diagnostic modalities used to detect coronary artery disease. Design: Systematic review and network meta-analysis. Data sources: Medline, Medline in process, Embase, Cochrane Library for clinical trials, PubMed, Web of Science, SCOPUS, WHO International Clinical Trials Registry Platform, and Clinicaltrials.gov. Eligibility criteria for selecting studies: Diagnostic randomised controlled trials comparing non-invasive diagnostic modalities in patients presenting with symptoms suggestive of low risk acute coronary syndrome or stable coronary artery disease. Data synthesis: A random effects network meta-analysis synthesised available evidence from trials evaluating the effect of non-invasive diagnostic modalities on downstream testing and patient oriented outcomes in patients with suspected coronary artery disease. Modalities included exercise electrocardiograms, stress echocardiography, single photon emission computed tomography-myocardial perfusion imaging, real time myocardial contrast echocardiography, coronary computed tomographic angiography, and cardiovascular magnetic resonance. Unpublished outcome data were obtained from 11 trials. Results: 18 trials of patients with low risk acute coronary syndrome (n=11 329) and 12 trials of those with suspected stable coronary artery disease (n=22 062) were included. Among patients with low risk acute coronary syndrome, stress echocardiography, cardiovascular magnetic resonance, and exercise electrocardiograms resulted in fewer invasive referrals for coronary angiography than coronary computed tomographic angiography (odds ratio 0.28 (95% confidence interval 0.14 to 0.57), 0.32 (0.15 to 0.71), and 0.53 (0.28 to 1.00), respectively). There was no effect on the subsequent risk of myocardial infarction, but estimates were imprecise. Heterogeneity and inconsistency were low. In patients with suspected stable coronary artery disease, an initial diagnostic strategy of stress echocardiography or single photon emission computed tomography-myocardial perfusion imaging resulted in fewer downstream tests than coronary computed tomographic angiography (0.24 (0.08 to 0.74) and 0.57 (0.37 to 0.87), respectively). However, exercise electrocardiograms yielded the highest downstream testing rate. Estimates for death and myocardial infarction were imprecise without clear discrimination between strategies. Conclusions: For patients with low risk acute coronary syndrome, an initial diagnostic strategy of stress echocardiography or cardiovascular magnetic resonance is associated with fewer referrals for invasive coronary angiography and revascularisation procedures than non-invasive anatomical testing, without apparent impact on the future risk of myocardial infarction. For suspected stable coronary artery disease, there was no clear discrimination between diagnostic strategies regarding the subsequent need for invasive coronary angiography, and differences in the risk of myocardial infarction cannot be ruled out. Systematic review registration: PROSPERO registry no CRD42016049442
Hospital revascularisation capability and quality of care after an acute coronary syndrome in Switzerland.
BACKGROUND: Patients with acute coronary syndrome (ACS) transferred to regional nonacademic hospitals after percutaneous coronary intervention (PCI) may receive fewer preventive interventions than patients who remain in university hospitals. We aimed at comparing hospitals with and without PCI facilities regarding guidelines-recommended secondary prevention interventions after an ACS.
METHODS: We studied patients with ACS admitted to a university hospital with PCI facilities in Switzerland, and either transferred within 48 hours to regional nonacademic hospitals without PCI facilities or directly discharged from the university hospital. We measured prescription rates of evidence-based recommended therapies after ACS including reasons for nonprescription of aspirin, statins, β-blockers, angiotensin converting-enzyme inhibitors (ACEI) / angiotensin II receptor blockers (ARB), along with cardiac rehabilitation attendance and delivery of a smoking cessation intervention.
RESULTS: Overall, 720 patients with ACS were enrolled; 541 (75.1%) were discharged from the hospital with PCI facilities, 179 (24.9%) were transferred to hospitals without PCI facilities. Concomitant prescription of aspirin, β-blockers, ACEI/ARB and statins at discharge was similar in hospitals with and without PCI facilities, reaching 83.9% and 85.5%, respectively (p = 0.62). Attendance at cardiac rehabilitation reached 55.5% for the hospital with PCI facilities and 65.7% for hospitals without PCI facilities (p = 0.02). In-hospital smoking cessation interventions were delivered to 70.8% patients exclusively at the hospital with PCI facilities.
CONCLUSION: Quality of care for patients with ACS discharged from hospitals without PCI facilities was similar to that of patients directly discharged from the hospital with PCI facilities, except for in-hospital smoking cessation counselling and cardiac rehabilitation attendance
Uptake and efficacy of a systematic intensive smoking cessation intervention using motivational interviewing for smokers hospitalised for an acute coronary syndrome: a multicentre before-after study with parallel group comparisons.
To compare the efficacy of a proactive approach with a reactive approach to offer intensive smoking cessation intervention using motivational interviewing (MI).
Before-after comparison in 2 academic hospitals with parallel comparisons in 2 control hospitals.
Academic hospitals in Switzerland.
Smokers hospitalised for an acute coronary syndrome (ACS).
In the intervention hospitals during the intervention phase, a resident physician trained in MI systematically offered counselling to all smokers admitted for ACS, followed by 4 telephone counselling sessions over 2 months by a nurse trained in MI. In the observation phase, the in-hospital intervention was offered only to patients whose clinicians requested a smoking cessation intervention. In the control hospitals, no intensive smoking cessation intervention was offered.
The primary outcome was 1 week smoking abstinence (point prevalence) at 12 months. Secondary outcomes were the number of smokers who received the in-hospital smoking cessation intervention and the duration of the intervention.
In the intervention centres during the intervention phase, 87% of smokers (N=193/225) received a smoking cessation intervention compared to 22% in the observational phase (p<0.001). Median duration of counselling was 50 min. During the intervention phase, 78% received a phone follow-up for a median total duration of 42 min in 4 sessions. Prescription of nicotine replacement therapy at discharge increased from 18% to 58% in the intervention phase (risk ratio (RR): 3.3 (95% CI 2.4 to 4.3; p≤0.001). Smoking cessation at 12-month increased from 43% to 51% comparing the observation and intervention phases (RR=1.20, 95% CI 0.98 to 1.46; p=0.08; 97% with outcome assessment). In the control hospitals, the RR for quitting was 1.02 (95% CI 0.84 to 1.25; p=0.8, 92% with outcome assessment).
A proactive strategy offering intensive smoking cessation intervention based on MI to all smokers hospitalised for ACS significantly increases the uptake of smoking cessation counselling and might increase smoking abstinence at 12 months
Robotic-assisted percutaneous coronary intervention: experience in Switzerland
Aims of the studyPercutaneous coronary intervention (PCI) exposes operators to ionizing radiation. Robotic-assisted PCI (RA-PCI) is a novel technology that enables interventional cardiologists to operate coronary devices remotely from a radiation-shed cockpit. The aim of this study is to describe the experience and challenges during the initiation of a RA-PCI program and to report outcomes of the first 21 patients undergoing RA-PCI in Switzerland.MethodsAll patients undergoing RA-PCI using the CorPath GRX Vascular Robotic System between 06/2021 and 12/2021 at Inselspital, Bern University Hospital were included in this retrospective registry study. Baseline, procedural and clinical follow-up data were prospectively assessed as part of the Cardiobase Bern PCI registry (NCT02241291). The two endpoints of interest were clinical success [defined as <30% residual diameter stenosis in the absence of in-hospital major adverse cardiovascular events (MACE: composite of death, periprocedural myocardial infarction, target-vessel revascularization, and stroke)] and robotic success (defined as clinical success and completion of RA-PCI without or with partial manual assistance). Additional outcome measures include clinical long-term outcomes at one year.ResultsTwenty-five lesions in 21 patients were treated with RA-PCI (age 62.4 ± 9.1 years, 24% female). Clinical success was achieved in 100%, and robotic success in 81% (17/21 procedures, including 4 procedures requiring partial manual assistance). Manual conversion (e.g. manual completion of the procedure) occurred in 19% (4 procedures). Reasons for manual assistance or conversion were poor guiding-catheter back-up or platform limitations (4), adverse events (2x transient slow-flow that was solved manually), safety decision (1x vasovagal reaction not related to robotic approach), and software error (1). No in-hospital MACE occurred. During 12 months of follow-up, one patient suffered a non-target-vessel myocardial infarction requiring repeat PCI.ConclusionsRA-PCI can safely be performed without clinically relevant robot-associated complications in selected patients with approximately 80% of procedures conducted without or with partial manual assistance
Repositionable Versus Balloon-Expandable Devices for Transcatheter Aortic Valve Implantation in Patients With Aortic Stenosis.
The safety and effectiveness of the fully repositionable LOTUS valve system as compared with the balloon-expandable Edwards SAPIEN 3 prosthesis for the treatment of aortic stenosis has not been evaluated to date.
All patients undergoing transcatheter aortic valve implantation with the Edwards SAPIEN 3 or the LOTUS valve system were included into the Swiss Transcatheter Aortic Valve Implantation Registry. An adjusted analysis was performed to compare the early clinical safety outcome according to the Valve Academic Research Consortium-2 definition. Between February 2014 and September 2015, 140 and 815 patients were treated with the LOTUS and the Edwards SAPIEN 3 valve, respectively. There was no difference in crude and adjusted analyses of the early safety outcome between patients treated with LOTUS (14.3%) and those treated with Edwards SAPIEN 3 (14.6%) (crude hazard ratio, 0.97; 95% CI, 0.61-1.56 [P=0.915]; adjusted hazard ratio, 1.03; 95% CI, 0.64-1.67 [P=0.909]). More than mild aortic regurgitation was <2% for both devices. A total of 34.3% of patients treated with LOTUS and 14.1% of patients treated with Edwards SAPIEN 3 required a permanent pacemaker (HR, 2.76; 95% CI, 1.97-3.87 [P<0.001]).
The repositionable LOTUS valve system and the balloon-expandable Edwards SAPIEN 3 prosthesis appeared comparable in regard to the Valve Academic Research Consortium-2 early safety outcome, and the rates of more than mild aortic regurgitation were exceedingly low for both devices. The need for new permanent pacemaker implantation was more frequent among patients treated with the LOTUS valve
Safety and efficacy of double vs. triple antithrombotic therapy in patients with atrial fibrillation with or without acute coronary syndrome undergoing percutaneous coronary intervention: a collaborative meta-analysis of non-vitamin K antagonist oral anticoagulant-based randomized clinical trials.
AIMS
Safety and efficacy of antithrombotic regimens in patients with atrial fibrillation (AF) undergoing percutaneous coronary intervention (PCI) may differ based on clinical presentation. We sought to compare double vs. triple antithrombotic therapy (DAT vs. TAT) in AF patients with or without acute coronary syndrome (ACS) undergoing PCI.
METHODS AND RESULTS
A systematic review and meta-analysis was performed using PubMed to search for non-vitamin K antagonist oral anticoagulant (NOAC)-based randomized clinical trials. Data on subgroups of ACS or elective PCI were obtained by published reports or trial investigators. A total of 10 193 patients from four NOAC trials were analysed, of whom 5675 presenting with ACS (DAT = 3063 vs. TAT = 2612) and 4518 with stable coronary artery disease (SCAD; DAT = 2421 vs. TAT = 2097). The primary safety endpoint of ISTH major bleeding or clinically relevant non-major bleeding was reduced with DAT compared with TAT in both ACS (12.2% vs. 19.4%; RR 0.63, 95% CI 0.56-0.71; P < 0.0001; I2 = 0%) and SCAD (14.6% vs. 22.0%; RR 0.68, 95% CI 0.55-0.85; P = 0.0008; I2 = 66%), without interaction (P-int = 0.54). Findings were consistent for secondary bleeding endpoints, including intra-cranial haemorrhage. In both subgroups, there was no difference between DAT and TAT for all-cause death, major adverse cardiovascular events, or stroke. Myocardial infarction and stent thrombosis were numerically higher with DAT vs. TAT consistently in ACS and SCAD (P-int = 0.60 and 0.86, respectively). Findings were confirmed by multiple sensitivity analyses, including a separate analysis on dabigatran regimens and a restriction to PCI population.
CONCLUSIONS
DAT, compared with TAT, is associated with lower bleeding risks, including intra-cranial haemorrhage, and a small non-significant excess of cardiac ischaemic events in both patients with or without ACS
Quality of care after acute coronary syndromes in a prospective cohort with reasons for non-prescription of recommended medications.
BACKGROUND: Adherence to guidelines is associated with improved outcomes of patients with acute coronary syndrome (ACS). Clinical registries developed to assess quality of care at discharge often do not collect the reasons for non-prescription for proven efficacious preventive medication in Continental Europe. In a prospective cohort of patients hospitalized for an ACS, we aimed at measuring the rate of recommended treatment at discharge, using pre-specified quality indicators recommended in cardiologic guidelines and including systematic collection of reasons for non-prescription for preventive medications.
METHODS: In a prospective cohort with 1260 patients hospitalized for ACS, we measured the rate of recommended treatment at discharge in 4 academic centers in Switzerland. Performance measures for medication at discharge were pre-specified according to guidelines, systematically collected for all patients and included in a centralized database.
RESULTS: Six hundred and eighty eight patients(54.6%) were discharged with a main diagnosis of STEMI, 491(39%) of NSTEMI and 81(6.4%) of unstable angina. Mean age was 64 years and 21.3% were women. 94.6% were prescribed angiotensin converting enzyme inhibitors/angiotensin II receptor blockers at discharge when only considering raw prescription rates, but increased to 99.5% when including reasons non-prescription. For statins, rates increased from 98% to 98.6% when including reasons for non-prescription and for beta-blockers, from 82% to 93%. For aspirin, rates further increased from 99.4% to 100% and from to 99.8% to 100% for P2Y12 inhibitors.
CONCLUSIONS: We found a very high adherence to ACS guidelines for drug prescriptions at discharge when including reasons for non-prescription to drug therapy. For beta-blockers, prescription rates were suboptimal, even after taking into account reason for non-prescription. In an era of improving quality of care to achieve 100% prescription rates at discharge unless contra-indicated, pre-specification of reasons for non-prescription for cardiovascular preventive medication permits to identify remaining gaps in quality of care at discharge.
TRIAL REGISTRATION: ClinicalTrials.gov NCT01000701
Health utility indexes in patients with acute coronary syndromes.
BACKGROUND: Acute coronary syndromes (ACS) have been associated with lower health utilities (HUs) compared with the general population. Given the prognostic improvements after ACS with the implementation of coronary angiography (eg, percutaneous coronary intervention (PCI)), contemporary HU values derived from patient-reported outcomes are needed.
METHODS: We analysed data of 1882 patients with ACS 1 year after coronary angiography in a Swiss prospective cohort. We used the EuroQol five-dimensional questionnaire (EQ-5D) and visual analogue scale (VAS) to derive HU indexes. We estimated the effects of clinical factors on HU using a linear regression model and compared the observed HU with the average values of individuals of the same sex and age in the general population.
RESULTS: Mean EQ-5D HU 1-year after coronary angiography for ACS was 0.82 (±0.16) and mean VAS was 0.77 (±0.18); 40.9% of participants exhibited the highest utility values. Compared with population controls, the mean EQ-5D HU was similar (expected mean 0.82, p=0.58) in patients with ACS, but the mean VAS was slightly lower (expected mean 0.79, p<0.001). Patients with ACS who are younger than 60 years had lower HU than the general population (<0.001). In patients with ACS, significant differences were found according to the gender, education and employment status, diabetes, obesity, heart failure, recurrent ischaemic or incident bleeding event and participation in cardiac rehabilitation (p<0.01).
CONCLUSIONS: At 1 year, patients with ACS with coronary angiography had HU indexes similar to a control population. Subgroup analyses based on patients' characteristics and further disease-specific instruments could provide better sensitivity for detecting smaller variations in health-related quality of life
- …