97 research outputs found
A Voltage Calibration Chain for Meters Used in Measurements of EV Inductive Power Charging
The inductive charging of electric vehicles requires specific measurement and
calibration systems. In fact, the measurement of power on board involves DC
signals, which are superimposed to a significant AC ripple up to or over 150
kHz, depending on the type of charging system. A calibration method that makes
use of a phantom power, based on two independent but synchronized circuits, is
considered, simulating the charging voltage and current. This paper describes
in detail a solution in the realization of the voltage calibration chain, based
on the use of a DC voltage calibrator, an injector and a voltage divider.Comment: 2 pages, Conference on Precision Electromagnetic Measurements (CPEM
2018), Paris
Asynchronous Phase Comparator for Characterization of Devices for PMUs Calibrator
This paper reports recent progress in developing a new asynchronous digital phase comparator for the precision measurement of phase difference of voltage ratio devices and calibration of functional elements of phasor measurement units (PMUs) calibrator. The phase error of the proposed digital comparator is below 300 nrad at 50 Hz and 100 ÎĽrad at 100 kHz with applied voltages ranging between 500 mV and 3 V, whereas the phase error of cables and connectors was estimated to be 4 ÎĽrad at 1 MHz. Besides resistive dividers, the phase comparator has been employed for the characterization of frequency behavior of phase difference between the output and input of voltage and transconductance amplifiers for a PMUs calibrator. The system can also be an important tool for phase-frequency characterization of devices employed for specific wideband power measurements
Wideband digital phase comparator for high current shunts
A wideband phase comparator for precise measurements of phase difference of
high current shunts has been developed at INRIM. The two-input digital phase
detector is realized with a precision wideband digitizer connected through a
pair of symmetric active guarded transformers to the outputs of the shunts
under comparison. Data are first acquired asynchronously, and then transferred
from on-board memory to host memory. Because of the large amount of data
collected the filtering process and the analysis algorithms are performed
outside the acquisition routine. Most of the systematic errors can be
compensated by a proper inversion procedure.
The system is suitable for comparing shunts in a wide range of currents, from
several hundred of milliampere up to 100 A, and frequencies ranging between 500
Hz and 100 kHz. Expanded uncertainty (k=2) less than 0.05 mrad, for frequency
up to 100 kHz, is obtained in the measurement of the phase difference of a
group of 10 A shunts, provided by some European NMIs, using a digitizer with
sampling frequency up to 1 MHz. An enhanced version of the phase comparator
employs a new digital phase detector with higher sampling frequency and
vertical resolution. This permits to decrease the contribution to the
uncertainty budget of the phase detector of a factor two from 20 kHz to 100
kHz. Theories and experiments show that the phase difference between two high
precision wideband digitizers, coupled as phase detector, depends on multiple
factors derived from both analog and digital imprint of each sampling system.Comment: 20 pages, 9 figure
Design and development of a coaxial cryogenic probe for precision measurements of the quantum hall effect in the ac regime
The quantum Hall effect is the basis for the realisation of the resistance and impedance units in the International System of units since 2019. This paper describes a cryogenic probe that allows to set graphene Hall devices in quantisation conditions in a helium bath (4.2 K) and magnetic fields up to 6 T, to perform precision measurements in the AC regime with impedance bridges. The probe has a full coaxial wiring, isolated from the probe structure, and holds the device in a TO-8 socket. First, characterization experiments are reported on a GaAs device, showing quantisation at 5.5 T. In the AC regime, multiple-series connections will be employed to minimize the residual error, quantified by electrical modelling of the probe
Un laboratorio di taratura e verifica dei contatori elettrici anche in condizioni di scarsa Power Quality
La misura accurata dell’energia elettrica `e determinante, oltre che per un’equa tariffazione, anche per
garantire l’osservabilit`a della rete elettrica. Nella transizione verso il concetto di smart grid, la diffusione
della microgenerazione e di carichi non lineari ha peggiorato i parametri di power quality della rete.
La misura delle corrispondenti forme d’onda di tensione e corrente, non pi`u sinusoidali, pu`o non avere
una riferibilit`a adeguata
How underground systems can contribute to meet the challenges of energy transition
The paper provides an overview of the several scientific and technical issues and challenges to be addressed for underground storage of carbon dioxide, hydrogen and mixtures of hydrogen and natural gas. The experience gained on underground energy systems and materials is complemented by new competences to adequately respond to the new needs raised by transition from fossil fuels to renewables. The experimental characterization and modeling of geological formations (including geochemical and microbiological issues), fluids and fluid-flow behavior and mutual interactions of all the systems components at the thermodynamic conditions typical of underground systems as well as the assessment and monitoring of safety conditions of surface facilities and infrastructures require a deeply integrated teamwork and fit-for-purpose laboratories to support theoretical research. The group dealing with large-scale underground energy storage systems of Politecnico di Torino has joined forces with the researchers of the Center for Sustainable Future Technologies of the Italian Institute of Technology, also based in Torino, to meet these new challenges of the energy transition era, and evidence of the ongoing investigations is provided in this paper
Importanza dei confronti di misura per i laboratori di taratura accreditati in Potenza ed Energia: stato dell’arte e attività INRIM
La legislazione corrente richiede la verifica dei contatori di energia residenziali e industriali e dei produttori di energia da parte di organismi certificati o laboratori di taratura accreditati. Questi ultimi assicurerebbero maggiore affidabilità perché sottoposti a sorveglianza anche mediante confronti di misura. L’INRIM dal 2016 fornisce confronti di potenza ed energia a frequenza industriale i cui risultati positivi confermano la correttezza dei processi di disseminazione e accreditamento
- …