483 research outputs found
In--out intermittency in PDE and ODE models
We find concrete evidence for a recently discovered form of intermittency,
referred to as in--out intermittency, in both PDE and ODE models of mean field
dynamos. This type of intermittency (introduced in Ashwin et al 1999) occurs in
systems with invariant submanifolds and, as opposed to on--off intermittency
which can also occur in skew product systems, it requires an absence of skew
product structure. By this we mean that the dynamics on the attractor
intermittent to the invariant manifold cannot be expressed simply as the
dynamics on the invariant subspace forcing the transverse dynamics; the
transverse dynamics will alter that tangential to the invariant subspace when
one is far enough away from the invariant manifold.
Since general systems with invariant submanifolds are not likely to have skew
product structure, this type of behaviour may be of physical relevance in a
variety of dynamical settings.
The models employed here to demonstrate in--out intermittency are
axisymmetric mean--field dynamo models which are often used to study the
observed large scale magnetic variability in the Sun and solar-type stars. The
occurrence of this type of intermittency in such models may be of interest in
understanding some aspects of such variabilities.Comment: To be published in Chaos, June 2001, also available at
http://www.eurico.web.co
Exact Results for Hamiltonian Walks from the Solution of the Fully Packed Loop Model on the Honeycomb Lattice
We derive the nested Bethe Ansatz solution of the fully packed O() loop
model on the honeycomb lattice. From this solution we derive the bulk free
energy per site along with the central charge and geometric scaling dimensions
describing the critical behaviour. In the limit we obtain the exact
compact exponents and for Hamiltonian walks, along with
the exact value for the connective constant
(entropy). Although having sets of scaling dimensions in common, our results
indicate that Hamiltonian walks on the honeycomb and Manhattan lattices lie in
different universality classes.Comment: 12 pages, RevTeX, 3 figures supplied on request, ANU preprint
MRR-050-9
Integration of radiation oncology teaching in medical studies by German medical faculties due to the new licensing regulations: an overview and recommendations of the consortium academic radiation oncology of the German Society for Radiation Oncology (DEGRO)
The new Medical Licensing Regulations 2025 (Ärztliche Approbationsordnung, ÄApprO) will soon be passed by the Federal Council (Bundesrat) and will be implemented step by step by the individual faculties in the coming months. The further development of medical studies essentially involves an orientation from fact-based to competence-based learning and focuses on practical, longitudinal and interdisciplinary training. Radiation oncology and radiation therapy are important components of therapeutic oncology and are of great importance for public health, both clinically and epidemiologically, and therefore should be given appropriate attention in medical education. This report is based on a recent survey on the current state of radiation therapy teaching at university hospitals in Germany as well as the contents of the National Competence Based Learning Objectives Catalogue for Medicine 2.0 (Nationaler Kompetenzbasierter Lernzielkatalog Medizin 2.0, NKLM) and the closely related Subject Catalogue (Gegenstandskatalog, GK) of the Institute for Medical and Pharmaceutical Examination Questions (Institut für Medizinische und Pharmazeutische Prüfungsfragen, IMPP). The current recommendations of the German Society for Radiation Oncology (Deutsche Gesellschaft für Radioonkologie, DEGRO) regarding topics, scope and rationale for the establishment of radiation oncology teaching at the respective faculties are also included
Temporal spatial and metabolic measures of walking in highly functional individuals with lower limb amputations
OBJECTIVE:
The aim of this descriptive exploratory study is to record the temporal spatial parameters and metabolic energy expenditure during walking of individuals with amputation, walking with advanced prostheses and following completion of comprehensive rehabilitation, to able-bodied controls.
DESIGN:
Cross-sectional
SETTING: Multi-disciplinary comprehensive rehabilitation centre
PARTICIPANTS: Thirty severely injured United Kingdom military personnel with amputation and subsequent completion of their rehabilitation programme (10 unilateral trans-tibial, 10 unilateral trans-femoral, and 10 bilateral trans-femoral) were compared to (and of similar age, height and mass (p < 0.537) as) 10 able-bodied controls.
INTERVENTIONS:
Not applicable Main Outcomes and Measures: Temporal spatial and metabolic energy expenditure data were captured during walking on level ground at self-selected speed.
RESULTS:
The individuals with amputation were all male, with a mean age 29 years (SD = 4) and mean New Injury Severity Score of 31 (SD = 16). Walking speed, stride length, step length and cadence of individuals with a unilateral trans-tibial or trans-femoral amputation was comparable to controls, and only for individuals with a bilateral trans-femoral amputation was walking speed significantly slower (1·12m/s, p = 0.025) and cadence reduced (96 steps/min, p = 0.026). Oxygen cost for individuals with a unilateral trans-tibial amputation (0·15 ml/kg/m) was the same as for controls (0·15 ml/kg/m), and significantly increased by 20% (0·18ml/kg/m, p = 0.023) for unilateral trans-femoral and by 60% (0·24 ml/kg/m, p < 0.001) for bilateral trans-femoral individuals with amputation.
CONCLUSION:
The scientific literature reports a wide range of gait and metabolic energy expenditure across individuals with amputation. The results of this study indicate that the individuals with amputation have a gait pattern which is highly functional and efficient. This is comparable to a small number of studies reporting similar outcomes for individuals with a unilateral trans-tibial amputation, but the results from this study are better than those on individuals with trans-femoral amputations reported elsewhere, despite comparison with populations wearing similar prosthetic componentry. Those studies that do report similar outcomes have included individuals who have been provided with a comprehensive rehabilitation programme. This suggests that such a programme may be as important as, or even more important than, prosthetic component selection in improving metabolic energy expenditure. The data are made available as a benchmark for what is achievable in the rehabilitation of some individuals with amputations, but agreeably may not be possible for all amputees to achieve
Optical techniques for 3D surface reconstruction in computer-assisted laparoscopic surgery
One of the main challenges for computer-assisted surgery (CAS) is to determine the intra-opera- tive morphology and motion of soft-tissues. This information is prerequisite to the registration of multi-modal patient-specific data for enhancing the surgeon’s navigation capabilites by observ- ing beyond exposed tissue surfaces and for providing intelligent control of robotic-assisted in- struments. In minimally invasive surgery (MIS), optical techniques are an increasingly attractive approach for in vivo 3D reconstruction of the soft-tissue surface geometry. This paper reviews the state-of-the-art methods for optical intra-operative 3D reconstruction in laparoscopic surgery and discusses the technical challenges and future perspectives towards clinical translation. With the recent paradigm shift of surgical practice towards MIS and new developments in 3D opti- cal imaging, this is a timely discussion about technologies that could facilitate complex CAS procedures in dynamic and deformable anatomical regions
In vitro degradation behavior and cytocompatibility of Mg–Zn–Zr alloys
Zinc and zirconium were selected as the alloying elements in biodegradable magnesium alloys, considering their strengthening effect and good biocompatibility. The degradation rate, hydrogen evolution, ion release, surface layer and in vitro cytotoxicity of two Mg–Zn–Zr alloys, i.e. ZK30 and ZK60, and a WE-type alloy (Mg–Y–RE–Zr) were investigated by means of long-term static immersion testing in Hank’s solution, non-static immersion testing in Hank’s solution and cell-material interaction analysis. It was found that, among these three magnesium alloys, ZK30 had the lowest degradation rate and the least hydrogen evolution. A magnesium calcium phosphate layer was formed on the surface of ZK30 sample during non-static immersion and its degradation caused minute changes in the ion concentrations and pH value of Hank’s solution. In addition, the ZK30 alloy showed insignificant cytotoxicity against bone marrow stromal cells as compared with biocompatible hydroxyapatite (HA) and the WE-type alloy. After prolonged incubation for 7 days, a stimulatory effect on cell proliferation was observed. The results of the present study suggested that ZK30 could be a promising material for biodegradable orthopedic implants and worth further investigation to evaluate its in vitro and in vivo degradation behavior
- …