84 research outputs found
Interobserver agreement for single operator choledochoscopy imaging: can we do better?
Background. The SpyGlass Direct Visualization System (Boston Scientific, Natick, MA) is routinely used during single operator choledochoscopy (SOC) to identify biliary lesions or strictures with a diagnostic accuracy up to 88%. The objective of this study was to determine the interobserver agreement (IOA) of modified scoring criteria for diagnosing biliary lesions/strictures. Methods. 27 SPY SOC video clips were reviewed and scored by 9 interventional endoscopists based on published criteria that included the presence and severity of surface structure, vasculature visualization, lesions, and findings. Results. Overall IOA was slight for all variables. The K statistics are as follows: surface (K = 0.12, SE = 0.02); vessels (K = 0.14, SE = 0.02); lesions (K = 0.11, SE = 0.02); findings (K = 0.08, SE = 0.03); and final diagnosis (K = 0.08, SE = 0.02). The IOA for findings and final diagnosis was also only slight. The final diagnosis was malignant (11), benign (11), and indeterminate (5). Conclusion. IOA using the modified criteria of SOC images was slight to almost poor. The average accuracy was less than 50%. These findings reaffirm that imaging criteria for benign and malignant biliary pathology need to be formally established and validated
Recommended from our members
Volumetric laser endomicroscopy and its application to Barrett's esophagus: results from a 1,000 patient registry.
Volumetric laser endomicroscopy (VLE) uses optical coherence tomography (OCT) for real-time, microscopic cross-sectional imaging. A US-based multi-center registry was constructed to prospectively collect data on patients undergoing upper endoscopy during which a VLE scan was performed. The objective of this registry was to determine usage patterns of VLE in clinical practice and to estimate quantitative and qualitative performance metrics as they are applied to Barrett's esophagus (BE) management. All procedures utilized the NvisionVLE Imaging System (NinePoint Medical, Bedford, MA) which was used by investigators to identify the tissue types present, along with focal areas of concern. Following the VLE procedure, investigators were asked to answer six key questions regarding how VLE impacted each case. Statistical analyses including neoplasia diagnostic yield improvement using VLE was performed. One thousand patients were enrolled across 18 US trial sites from August 2014 through April 2016. In patients with previously diagnosed or suspected BE (894/1000), investigators used VLE and identified areas of concern not seen on white light endoscopy (WLE) in 59% of the procedures. VLE imaging also guided tissue acquisition and treatment in 71% and 54% of procedures, respectively. VLE as an adjunct modality improved the neoplasia diagnostic yield by 55% beyond the standard of care practice. In patients with no prior history of therapy, and without visual findings from other technologies, VLE-guided tissue acquisition increased neoplasia detection over random biopsies by 700%. Registry investigators reported that VLE improved the BE management process when used as an adjunct tissue acquisition and treatment guidance tool. The ability of VLE to image large segments of the esophagus with microscopic cross-sectional detail may provide additional benefits including higher yield biopsies and more efficient tissue acquisition. Clinicaltrials.gov NCT02215291
Global prospective case series of ERCPs using a single-use duodenoscope
Background The first commercialized single-use duodenoscope was cleared by the US Food and Drug Administration in December 2019. Data regarding endoscopic retrograde cholangiopancreatography (ERCP) using a single-use duodenoscope are needed on a broader range of cases conducted by endoscopists with varying levels of experience in a wide range of geographic areas. Methods 61 endoscopists at 22 academic centers in 11 countries performed ERCP procedures in adult patients aged ? 18. Outcomes included ERCP completion for the intended indication, rate of crossover to a reusable endoscope, device performance ratings, and serious adverse events (SAEs). Results Among 551 patients, 236 (42.8 %) were aged >65, 281 (51.0 %) were men, and 256 (46.5 %) had their procedure as an inpatient. ERCPs included 196 (35.6 %) with American Society for Gastrointestinal Endoscopy complexity of grades 3 4. A total of 529 ERCPs (96.0 %) were completed: 503 (91.3 %) using only the single-use duodenoscope, and 26 (4.7 %) with crossover to a reusable endoscope. There were 22 ERCPs (4.0 %) that were not completed, of which 11 (2.0 %) included a crossover and 11 (2.0 %) were aborted cases (no crossover). Median ERCP completion time was 24.0 minutes. Median overall satisfaction with the single-use duodenoscope was 8.0 (scale of 1 to 10 [best]). SAEs were reported in 43 patients (7.8 %), including 17 (3.1 %) who developed post-ERCP pancreatitis. Conclusions In academic medical centers over a wide geographic distribution, endoscopists with varying levels of experience using the first marketed single-use duodenoscope had good ERCP procedural success and reported high performance ratings for this device.</p
Recommended from our members
Light scattering spectroscopy identifies the malignant potential of pancreatic cysts during endoscopy
Pancreatic cancers are usually detected at an advanced stage and have poor prognosis. About one fifth of these arise from pancreatic cystic lesions. Yet not all lesions are precancerous, and imaging tools lack adequate accuracy for distinguishing precancerous from benign cysts. Therefore, decisions on surgical resection usually rely on endoscopic ultrasound-guided fine needle aspiration (EUS-FNA). Unfortunately, cyst fluid often contains few cells, and fluid chemical analysis lacks accuracy, resulting in dire consequences, including unnecessary pancreatic surgery for benign cysts and the development of cancer. Here, we report an optical spectroscopic technique, based on a spatial gating fibre-optic probe, that predicts the malignant potential of pancreatic cystic lesions during routine diagnostic EUS-FNA procedures. In a double-blind prospective study in 25 patients, with 14 cysts measured in vivo and 13 postoperatively, the technique achieved an overall accuracy of 95%, with a 95%confidence interval of 78–99%, in cysts with definitive diagnosis
Antireflux Transoral Incisionless Fundoplication Using EsophyX: 12-Month Results of a Prospective Multicenter Study
BACKGROUND: A novel transoral incisionless fundoplication (TIF) procedure using the EsophyX system with SerosaFuse fasteners was designed to reconstruct a full-thickness valve at the gastroesophageal junction through tailored delivery of multiple fasteners during a single-device insertion. The safety and efficacy of TIF for treating gastroesophageal reflux disease (GERD) were evaluated in a prospective multicenter trial. METHODS: Patients (n = 86) with chronic GERD treated with proton pump inhibitors (PPIs) were enrolled. Exclusion criteria included an irreducible hiatal hernia > 2 cm. RESULTS: The TIF procedure (n = 84) reduced all hiatal hernias (n = 49) and constructed valves measuring 4 cm (2-6 cm) and 230 degrees (160 degrees -300 degrees ). Serious adverse events consisted of two esophageal perforations upon device insertion and one case of postoperative intraluminal bleeding. Other adverse events were mild and transient. At 12 months, aggregate (n = 79) and stratified Hill grade I tight (n = 21) results showed 73% and 86% of patients with >or=50% improvement in GERD health-related quality of life (HRQL) scores, 85% discontinuation of daily PPI use, and 81% complete cessation of PPIs; 37% and 48% normalization of esophageal acid exposure; 60% and 89% hiatal hernia reduction; and 62% and 80% esophagitis reduction, respectively. More than 50% of patients with Hill grade I tight valves had a normalized cardia circumference. Resting pressure of the lower esophageal sphincter (LES) was improved significantly (p < 0.001), by 53%. EsophyX-TIF cured GERD in 56% of patients based on their symptom reduction and PPI discontinuation. CONCLUSION: The 12-month results showed that EsophyX-TIF was safe and effective in improving quality of life and for reducing symptoms, PPI use, hiatal hernia, and esophagitis, as well as increasing the LES resting pressure and normalizing esophageal pH and cardia circumference in chronic GERD patients.Journal ArticleMulticenter StudyResearch Support, Non-U.S. Gov'tinfo:eu-repo/semantics/publishe
Effects of Blended (Yellow) vs Forced Coagulation (Blue) Currents on Adverse Events, Complete Resection, or Polyp Recurrence After Polypectomy in a Large Randomized Trial
Background & aims: There is debate over the type of electrosurgical setting that should be used for polyp resection. Some endoscopists use a type of blended current (yellow), whereas others prefer coagulation (blue). We performed a single-blinded, randomized trial to determine whether type of electrosurgical setting affects risk of adverse events or recurrence.
Methods: Patients undergoing endoscopic mucosal resection of nonpedunculated colorectal polyps 20 mm or larger (n = 928) were randomly assigned, in a 2 × 2 design, to groups that received clip closure or no clip closure of the resection defect (primary intervention) and then to either a blended current (Endocut Q) or coagulation current (forced coagulation) (Erbe Inc) (secondary intervention and focus of the study). The study was performed at multiple centers, from April 2013 through October 2017. Patients were evaluated 30 days after the procedure (n = 919), and 675 patients underwent a surveillance colonoscopy at a median of 6 months after the procedure. The primary outcome was any severe adverse event in a per patient analysis. Secondary outcomes were complete resection and recurrence at first surveillance colonoscopy in a per polyp analysis.
Results: Serious adverse events occurred in 7.2% of patients in the Endocut group and 7.9% of patients in the forced coagulation group, with no significant differences in the occurrence of types of events. There were no significant differences between groups in proportions of polyps that were completely removed (96% in the Endocut group vs 95% in the forced coagulation group) or the proportion of polyps found to have recurred at surveillance colonoscopy (17% and 17%, respectively). Procedural characteristics were comparable, except that 17% of patients in the Endocut group had immediate bleeding that required an intervention, compared with 11% in the forced coagulation group (P = .006).
Conclusions: In a randomized trial to compare 2 commonly used electrosurgical settings for the resection of large colorectal polyps (Endocut vs forced coagulation), we found no difference in risk of serious adverse events, complete resection rate, or polyp recurrence. Electrosurgical settings can therefore be selected based on endoscopist expertise and preference
Clip Closure Prevents Bleeding After Endoscopic Resection of Large Colon Polyps in a Randomized Trial
Background & aims: Bleeding is the most common severe complication after endoscopic mucosal resection of large colon polyps and is associated with significant morbidity and cost. We examined whether prophylactic closure of the mucosal defect with hemoclips after polyp resection reduces the risk of bleeding.
Methods: We performed a multicenter, randomized trial of patients with a large nonpedunculated colon polyp (≥20 mm) at 18 medical centers in North America and Spain from April 2013 through October 2017. Patients were randomly assigned to groups that underwent endoscopic closure with a clip (clip group) or no closure (control group) and followed. The primary outcome, postprocedure bleeding, was defined as a severe bleeding event that required hospitalization, a blood transfusion, colonoscopy, surgery, or another invasive intervention within 30 days after completion of the colonoscopy. Subgroup analyses included postprocedure bleeding with polyp location, polyp size, or use of periprocedural antithrombotic medications. We also examined the risk of any serious adverse event.
Results: A total of 919 patients were randomly assigned to groups and completed follow-up. Postprocedure bleeding occurred in 3.5% of patients in the clip group and 7.1% in the control group (absolute risk difference [ARD] 3.6%; 95% confidence interval [CI] 0.7%-6.5%). Among 615 patients (66.9%) with a proximal large polyp, the risk of bleeding in the clip group was 3.3% and in the control group was 9.6% (ARD 6.3%; 95% CI 2.5%-10.1%); among patients with a distal large polyp, the risks were 4.0% in the clip group and 1.4% in the control group (ARD -2.6%; 95% CI -6.3% to -1.1%). The effect of clip closure was independent of antithrombotic medications or polyp size. Serious adverse events occurred in 4.8% of patients in the clip group and 9.5% of patients in the control group (ARD 4.6%; 95% CI 1.3%-8.0%).
Conclusions: In a randomized trial, we found that endoscopic clip closure of the mucosal defect following resection of large colon polyps reduces risk of postprocedure bleeding. The protective effect appeared to be restricted to large polyps located in the proximal colon
Rectal Indomethacin Dose Escalation (RIDE) for Prevention of Post-ERCP Pancreatitis in High-Risk Patients: a Randomized Trial
Background
Although rectal indometacin 100 mg is effective in reducing the frequency and severity of pancreatitis after endoscopic retrograde cholangiopancreatography (ERCP) in high-risk patients, the optimal dose is unknown, and pancreatitis incidence remains high. The aim of this study was to compare the efficacy of two dose regimens of rectal indometacin on the frequency and severity of pancreatitis after ERCP in high-risk patients.
Methods
In this randomised, double-blind, comparative effectiveness trial, we enrolled patients from six tertiary medical centres in the USA. Eligible patients were those at high risk for the development of pancreatitis after ERCP. We randomly assigned eligible patients (1:1) immediately after ERCP to receive either two 50 mg indometacin suppositories and a placebo suppository (standard-dose group) or three 50 mg indometacin suppositories (high-dose group). 4 h after the procedure, patients assigned to the high-dose group received an additional 50 mg indometacin suppository, whereas patients in the standard-dose group received an additional placebo suppository. The randomisation schedule, stratified according to study centre and with no other restrictions, was computer generated by an investigator who was uninvolved in the clinical care of any participants, distributed to the sites, and kept by personnel not directly involved with the study. These same personnel were responsible for packaging the drug and placebo in opaque envelopes. Patients, study personnel, and treating physicians were masked to study group assignment. The primary outcome of the study was the development of pancreatitis after ERCP. Analyses were done on an intention-to-treat basis. This trial is registered with ClinicalTrials.gov, number NCT01912716, and enrolment is complete.
Findings
Between July 9, 2013, and March 22, 2018, 1037 eligible patients were enrolled and randomly assigned to receive either standard-dose (n=515) or high-dose indometacin (n=522). Pancreatitis after ERCP occurred in 141 (14%) of 1037 patients—76 (15%) of 515 patients in the standard-dose indometacin group and 65 (12%) of 522 patients in the high-dose indometacin group (risk ratio [RR] 1·19, 95% CI 0·87–1·61; p=0·32). We observed 19 adverse events that were potentially attributable to study drug. Clinically significant bleeding occurred in 14 (1%) of 1037 patients—six (1%) of 515 patients in the standard-dose indometacin group and eight (2%) of 522 patients in the high-dose indometacin group (p=0·79). Three (1%) of 522 patients in the high-dose indometacin group developed acute kidney injury versus none in the standard-dose group (p=0·25). A non-ST elevation myocardial infarction occurred in the standard-dose indometacin group 2 days after ERCP. A transient ischaemic attack occurred in the high-dose indometacin group 5 days after ERCP. All 19 adverse events, in addition to the 141 patients who developed pancreatitis after ERCP, were considered serious as all required admission to hospital. We observed no allergic reactions or deaths at 30 day follow-up.
Interpretation
Dose escalation to rectal indometacin 200 mg did not confer any advantage compared with the standard 100 mg regimen, with pancreatitis incidence remaining high in high-risk patients. Current practice should continue unchanged. Further research should consider the pharmacokinetics of non-steroidal anti-inflammatory drugs to determine the optimal timing of their administration to prevent pancreatitis after ERCP
Severe Asthma Standard-of-Care Background Medication Reduction With Benralizumab: ANDHI in Practice Substudy
peer reviewedBackground: The phase IIIb, randomized, parallel-group, placebo-controlled ANDHI double-blind (DB) study extended understanding of the efficacy of benralizumab for patients with severe eosinophilic asthma. Patients from ANDHI DB could join the 56-week ANDHI in Practice (IP) single-arm, open-label extension substudy. Objective: Assess potential for standard-of-care background medication reductions while maintaining asthma control with benralizumab. Methods: Following ANDHI DB completion, eligible adults were enrolled in ANDHI IP. After an 8-week run-in with benralizumab, there were 5 visits to potentially reduce background asthma medications for patients achieving and maintaining protocol-defined asthma control with benralizumab. Main outcome measures for non–oral corticosteroid (OCS)-dependent patients were the proportions with at least 1 background medication reduction (ie, lower inhaled corticosteroid dose, background medication discontinuation) and the number of adapted Global Initiative for Asthma (GINA) step reductions at end of treatment (EOT). Main outcomes for OCS-dependent patients were reductions in daily OCS dosage and proportion achieving OCS dosage of 5 mg or lower at EOT. Results: For non–OCS-dependent patients, 53.3% (n = 208 of 390) achieved at least 1 background medication reduction, increasing to 72.6% (n = 130 of 179) for patients who maintained protocol-defined asthma control at EOT. A total of 41.9% (n = 163 of 389) achieved at least 1 adapted GINA step reduction, increasing to 61.8% (n = 110 of 178) for patients with protocol-defined EOT asthma control. At ANDHI IP baseline, OCS dosages were 5 mg or lower for 40.4% (n = 40 of 99) of OCS-dependent patients. Of OCS-dependent patients, 50.5% (n = 50 of 99) eliminated OCS and 74.7% (n = 74 of 99) achieved dosages of 5 mg or lower at EOT. Conclusions: These findings demonstrate benralizumab's ability to improve asthma control, thereby allowing background medication reduction. © 202
- …