69,298 research outputs found
Contamination of stellar-kinematic samples and uncertainty about dark matter annihilation profiles in ultrafaint dwarf galaxies: the example of Segue I
The expected gamma-ray flux coming from dark matter annihilation in dwarf
spheroidal (dSph) galaxies depends on the so-called `J-factor', the integral of
the squared dark matter density along the line-of-sight. We examine the degree
to which estimates of J are sensitive to contamination (by foreground Milky Way
stars and stellar streams) of the stellar-kinematic samples that are used to
infer dark matter densities in `ultrafaint' dSphs. Applying standard kinematic
analyses to hundreds of mock data sets that include varying levels of
contamination, we find that mis-classified contaminants can cause J-factors to
be overestimated by orders of magnitude. Stellar-kinematic data sets for which
we obtain such biased estimates tend 1) to include relatively large fractions
of stars with ambiguous membership status, and 2) to give estimates for J that
are sensitive to specific choices about how to weight and/or to exclude stars
with ambiguous status. Comparing publicly-available stellar-kinematic samples
for the nearby dSphs Reticulum~II and Segue~I, we find that only the latter
displays both of these characteristics. Estimates of Segue~I's J-factor should
therefore be regarded with a larger degree of caution when planning and
interpreting gamma-ray observations. Moreover, robust interpretations regarding
dark matter annihilation in dSph galaxies in general will require explicit
examination of how interlopers might affect the inferred dark matter density
profile.Comment: 12 pages, 8 figures. New appendix A (joint light/dark matter
likelihood), results unchanged. Match accepted MNRAS versio
Optical Constants of Magnesium Oxide in the Far Ultraviolet
Optical constants of magnesium oxide in far ultraviole
Optical Constants of Lithium Fluoride in the Far Ultraviolet
Optical constants of lithium fluoride in far ultraviole
Spherical Jeans analysis for dark matter indirect detection in dwarf spheroidal galaxies - Impact of physical parameters and triaxiality
Dwarf spheroidal (dSph) galaxies are among the most promising targets for the
indirect detection of dark matter (DM) from annihilation and/or decay products.
Empirical estimates of their DM content - and hence the magnitudes of expected
signals - rely on inferences from stellar-kinematic data. However, various
kinematic analyses can give different results and it is not obvious which are
most reliable. Using extensive sets of mock data of various sizes (mimicking
'ultra-faint' and 'classical' dSphs) and an MCMC engine, here we investigate
biases, uncertainties, and limitations of analyses based on parametric
solutions to the spherical Jeans equation. For a variety of functional forms
for the tracer and DM density profiles, as well as the orbital anisotropy
profile, we examine reliability of estimates for the astrophysical J- and
D-factors for annihilation and decay, respectively. For large (N > 1000)
stellar-kinematic samples typical of 'classical' dSphs, errors tend to be
dominated by systematics, which can be reduced through the use of sufficiently
general and flexible functional forms. For small (N < 100) samples typical of
'ultrafaints', statistical uncertainties tend to dominate systematic errors and
flexible models are less necessary. We define an optimal strategy that would
mitigate sensitivity to priors and other aspects of analyses based on the
spherical Jeans equation. We also find that the assumption of spherical
symmetry can bias estimates of J (with the 95% credibility intervals not
encompassing the true J-factor) when the object is mildly triaxial (axis ratios
b/a = 0.8, c/a = 0.6). A concluding table summarises the typical error budget
and biases for the different sample sizes considered.Comment: 21 pages, 20 figures. Minor changes (several clarifications): match
the MNRAS accepted versio
Recommendations for high intensity upper body exercise testing
Introduction: For given submaximal and maximal peak power outputs aerobic responses to upper body exercise are different to those for lower body exercise (Sawka, 1986: Exercise & Sport Sciences Reviews, 14, 175-211). However, much less is known regarding responses to exercise intensities at and around peak oxygen up take (VO2peak). Purpose: The purpose of this study was to determine the metabolic responses during arm crank ergometry (ACE) below, at and above peak oxygen uptake and to help establish exercise testing guidelines for high intensity upper body exercise. Methods: Following institutional ethical approval fourteen male students (Age 21.1, s = 6.1 years and 2.44 s=0.44 VO2peak) volunteered to take part in this study. Each participant exercised on a table mounted cycle ergometer (Monark 894E, Monark Exercise AB, Sweden). After habituation peak minute power (PMP) was calculated from an incremental test. Subsequently each participant completed four continuous work tests (CWT) to volitional exhaustion at 80%, 90%, 100% and 110% of PMP. All tests were completed at 70 rev∙min-1 with a minimum of 48-h between tests and the order was counterbalanced. Each CWT was preceded by a 5 min warm-up, loaded with a mass corresponding to the participants 80% PMP for 20 s at minutes 2, 3 and 4. Oxygen uptake (VO2), respiratory exchange ratio (RER), heart rate (HR) and ratings of perceived exertion for the arms (local (RPEL) and cardiorespiratory strain (RPECR) were recorded at 1 min, 2 min and at volitional exhaustion. The EMG responses at three sites (flexor carpi ulnaris, biceps brachii and triceps brachii lateral) were recorded using double-differential (16-3000 Hz bandwidth, x300 gain), bipolar, active electrodes (MP-2A, Linton, Norfolk, UK). Electromyographic data were sampled at 1000 Hz and filtered using a 20 to 500 Hz band-pass filter (MP150 Data Acquisition and AcqKnowledge 4.0, Biopac, Goleta, CA). The EMG signals for each muscle were root mean squared (RMS) with a 500-ms sample window. The signal was then normalised, prior to each CWT, as a percentage of the mean of 3 sets of 10 duty cycles completed during the warm-up (see above) when the participants 80% PMP for 20 s was applied. Time to exhaustion (Tlim) was recorded as the performance outcome measure. Data for Tlim were analysed using one-way analysis of variance. Differences in EMG, VO2, RER, HR, RPEL and RPECR were analysed using separate two-way analysis of variance with repeated measures (trial x time). All analyses were performed using the Statistical Package for Social Sciences ( 17.0; SPSS Inc., Chicago, IL). Individual differences in means were located using Bonferroni post-hoc correction. Significance was accepted at P < 0.05. Results: As resistive load increased Tlim decreased (611 s=194, 397 s=99, 268 s=90, 206 s=67s, respectively; P < 0.001, ES = 0.625). Post-hoc analysis revealed that Tlim using 80%PMP was longer than for 90%, 100% and 110% PMP trials (P < 0.001) and 90% was longer than both 100% and 110% PMP trials (P = 0.079, P = 0.001). At exhaustion VO2 was similar across trials (P = 0.413, ES = 0.053), although 80% PMP VO2 tended to be less (2.10 s=0.32 l·min-1) than for 90% (2.29 s=0.37), 100% (2.33 s=0.49) and 110% (2.26 s=0.34). Also, 80% PMP VO2 was less than VO2peak (P = 0.013). There were differences in RER at Tlim (P < 0.001, ES = 0.593) with values increasing with % PMP (1.15 s=0.07, 1.26 s=0.07, 1.36 s=0.10, 1.40 s=0.09, respectively). There were no differences across trials for HR at Tlim (~173 (12); P = 0.834, ES = 0.016) and HR was proportional to %PMP at 1 min, and 2 min. For flexor carpi ulnaris there was an increase in activation as exercise intensity increased (P < 0.001, ES = 0.245). There were a similar responses for biceps brachii and triceps brachii demonstrating an increase in activation with exercise intensity (P <0.001, ES = 0.137, P < 0.001, ES = 0.163, respectively). No differences for RPEL and RPECR were observed at Tlim. Discussion: There was a clear response of Tlim with intensity as expected for lower body exercise (Hill et al., 2002: Medicine and Science in Sports and Exercise, 34(4), 709-714). Despite differences in Tlim across exercise intensities VO2, HR and RPE were similar at exhaustion indicating a functional cardiorespiratory maximum had been reached. As indicated by the RER an increased activation of the anaerobic metabolism with greater exercise intensities (100% and 110%) is likely and therefore this may represent a greater anaerobic component at these two intensities. The increase in EMG activity with intensity could indicate an increase activity with an increase in exercise intensity. Conclusion: It is recommended that due to the combination of muscle activation, oxygen uptake and Tlim that an exercise intensity of 90% or 100% of PMP could be used for high intensity upper body exercise testing
Computer Program for Assessing the Economic Feasibility of Solar Energy for Single Family Residences and Light Commercial Applications
Computer program, SHCOST, was used to perform economic analyses of operational test sites. The program allows consideration of the economic parameters which are important to the solar system user. A life cycle cost and cash flow comparison is made between a solar heating system and a conventional system. The program assists in sizing the solar heating system. A sensitivity study and plot capability allow the user to select the most cost effective system configuration
Pore geometry as a control on rock strength
This study was funded via RJW's University of Leicester start-up fund, as part of AAB's PhD project. We thank Don Swanson and Mike Poland at HVO, Hawai'i, for their help and advice during fieldwork planning and sample collection in the Koa'e fault system, and the National Park Service for granting a research permit to collect rock samples. Sergio Vinciguerra is thanked for access to the Rock Mechanics and Physics lab at the British Geological Survey and Audrey Ougier-Simonin is thanked for her help preparing samples and advice during testing. We thank Mike Heap (EOST Strasbourg) and an anonymous reviewer for their detailed and careful comments that greatly improved the manuscript.Peer reviewedPostprin
Flame detector operable in presence of proton radiation
A detector of ultraviolet radiation for operation in a space vehicle which orbits through high intensity radiation areas is described. Two identical ultraviolet sensor tubes are mounted within a shield which limits to acceptable levels the amount of proton radiation reaching the sensor tubes. The shield has an opening which permits ultraviolet radiation to reach one of the sensing tubes. The shield keeps ultraviolet radiation from reaching the other sensor tube, designated the reference tube. The circuitry of the detector subtracts the output of the reference tube from the output of the sensing tube, and any portion of the output of the sensing tube which is due to proton radiation is offset by the output of the reference tube. A delay circuit in the detector prevents false alarms by keeping statistical variations in the proton radiation sensed by the two sensor tubes from developing an output signal
- …