2,356 research outputs found

    Обґрунтування можливості очищення підземних вод із понаднормовим вмістом Fe2+ і Mn2+ за допомогою спрощеної аерації по безреагентній схем

    Get PDF
    The analysis of traditional demanganation technologies is presented. The oxidation of dissolved forms – Fe2+ and Mn2+ by simplified aeration with atmospheric O2 is considered. A thermodynamic justification for the possibility of this process and the presence of an energy barrier in the oxidation of Mn2+ is given. The natural factors that contribute to overcoming the energy barrier, which at the same time are widely distributed in typical underground waters, are analyzed. The role of iron in this process, the phase difference — liquid/solid, the adsorption capacity of the solid phase relative to Mn2+ and the influence of the biogenic factor are shown. The biogeochemical cycle of manganese is analyzed. Based on the natural biogeochemical cycle of manganese, the industrial facilities have been constructed that provide a chain of technological processes capable to overcome the energy barrier using a reagent-free scheme when water with the excess concentrations of Fe2+ and Mn2+is demagnetized by oxidizing with atmospheric oxygen.Представлено аналіз традиційних технологій деманганації. Розглянуто окиснення  розчинних Fe2+ і Mn2+ за допомогою спрощеної аерації атмосферним О2. Наведено термодинамічне обґрунтування можливості протікання цього процесу і означена присутність енергетичного бар’єра при окисненні Mn2+. Проаналізовані природні чинники, що сприяють подоланню енергетичного бар’єра і які  є поширеними елементами, що входять до складу типових підземних вод. Розкрита роль у цьому процесі заліза, різниці фаз – рідка/тверда, адсорбційної здатності твердої фази відносно Mn2+ та впливу біогенного фактора і його особливості. Проаналізовано біогеохімічний цикл марганцю. Спираючись на природні процеси, що відбуваються в процесі біогеохімічного циклу марганцю, збудовано промислові установки, що забезпечують  ланцюг із технологічних процесів, здатних за безреагентною схемою долати енергетичний бар’єр при деманганації вод з понаднормовими концентраціями  Fe2+ і Mn2+ шляхом їх окиснення атмосферним киснем

    Pre-Congestion Notification marking

    Get PDF
    Pre-Congestion Notification (PCN) builds on the concepts of RFC 3168, "The addition of Explicit Congestion Notification to IP". However, Pre-Congestion Notification aims at providing notification before any congestion actually occurs. Pre-Congestion Notification is applied to real-time flows (such as voice, video and multimedia streaming) in DiffServ networks. As described in [CL-DEPLOY], it enables "pre" congestion control through two procedures, flow admission control and flow pre-emption. The draft proposes algorithms that determine when a PCN-enabled router writes Admission Marking and Pre-emption Marking in a packet header, depending on the traffic level. The draft also proposes how to encode these markings. We present simulation results with PCN working in an edge-to-edge scenario using the marking algorithms described. Other marking algorithms will be investigated in the future

    Дослідження ефективності роботи контактного фільтра з пінополістирольним фільтруючим завантаженням при очищенні природних поверхневих вод

    Get PDF
    Residual aluminium is one of the standard indicators of the quality of water treatment facilities. Due to a number of interrelated factors to keep its regulatory concentration in purified water is becoming increasingly difficult. Proposed solution simplifies this task. It is based on the reconstruction of existing facilities — flocculation chambers horizontal tanks in contact Filters — Prefilters. After the reconstruction of such structures can serve as the contact filters, coagulation in cramped conditions and prefilters for the detention of phytoplankton. Full-scale simulation of such a facility, using the use of filter media made of foamed polystyrene granules. The dependence of the concentration of residual aluminium on the filtration rate and the dirt holding capacity of such a combined structure were defined.Залишковий алюміній є одним із стандартних показників якості роботи водопровідних очисних споруд. У зв’язку з низкою взаємопов’язаних факторів утримувати його нормативні концентрації в очищеній воді стає дедалі важче. Запропоновано рішення, що спрощує це завдання. Воно базується на переобладнанні існуючих споруд – камер утворення пластівців горизонтальних відстійників — у контактні фільтри . Після реконструкції такі споруди здатні виконувати функції контактних фільтрів, з коагуляцією у стиснених умовах, і попередніх фільтрів для затримання фітопланктону. Проведено натурне моделювання роботи такої установки із застосуванням плаваючого фільтруючого завантаження. Визначені залежності концентрацій залишкового  алюмінію від швидкості фільтрування, а також  брудомісткість такої комбінованої споруди

    Deterministic Edge-to-Edge Delay Bounds for a Flow in a DiffServ Network Domain

    Full text link

    Adequate symptom relief justifies hepatic resection for benign disease

    Get PDF
    BACKGROUND: The purpose of this study was to evaluate the long-term results of partial liver resection for benign liver lesions. METHODS: All patients operated on for benign liver lesions from 1991 to 2002 were included. Information was retrieved from medical records, the hospital registration system and by a telephonic questionnaire. RESULTS: Twenty-eight patients with a median age of 41 years (17–71) were operated on (M/F ratio 5/23). The diagnosis was haemangioma in 8 patients, FNH in 6, HCA in 13 and angiomyolipoma in 1. Eight patients were known to have relevant co-morbidity. Median operating time was 207 minutes (45–360). The morbidity rate was 25% and no postoperative mortality was observed. Twenty-two patients (79%) had symptoms (mainly abdominal pain) prior to surgery. Twenty-five patients were reached for a questionnaire. The median follow up was 55 months (4–150). In 89% of patients preoperative symptoms had decreased or disappeared after surgery. Four patients developed late complications. CONCLUSION: Long-term follow up after liver surgery for benign liver lesions shows considerable symptom relief and patient satisfaction. In addition to a correct indication these results justify major surgery with associated morbidity and mortality

    Pre-Congestion Notification marking

    Get PDF
    Pre-Congestion Notification (PCN) builds on the concepts of RFC 3168, "The addition of Explicit Congestion Notification to IP". However, Pre-Congestion Notification aims at providing notification before any congestion actually occurs. Pre-Congestion Notification is applied to \ud real-time flows (such as voice, video and multimedia streaming) in DiffServ networks. As described in [CL-DEPLOY], it enables "pre" congestion control through two procedures, flow admission control and flow pre-emption. The draft proposes algorithms that determine when a \ud PCN-enabled router writes Admission Marking and Pre-emption Marking in a packet header, depending on the traffic level. The draft also proposes how to encode these markings. We present simulation results with PCN working in an edge-to-edge scenario using the marking algorithms described. Other marking algorithms will be investigated in the future. \u

    ДОСЛІДЖЕННЯ ОРТОПОЛІФОСФАТНОГО ПРЕПАРАТУ “SEA QUEST LIQUID” ДЛЯ АНТИКОРОЗІЙНОЇ ТА СТАБІЛІЗАЦІЙНОЇ ОБРОБКИ ВОДИ

    Get PDF
    Most water supply systems operating in Ukraine are made of steel or cast iron, which are subject to corrosion. The Institute of Water Problems and Land Reclamation of the National Academy of Sciences of Ukraine carried out the experimental studies on the effect of an orthophosphate corrosion inhibitor on the quality of drinking water and the rate of corrosion as a result of its appliance in various doses in the water supply network. The water supply system of Obolon district of the city of Kiev was selected as the object of research. A characteristic feature of this water supply system is the use of various sources of water supply - groundwater and surface waters of the Desna and Dnieper rivers. The results of the calculation of water corrosivity carried out at the Institute based on the chemical analysis of the quality of water taken from 29 wells at the research object showed that the Langelier indices obtained using the calculation formulas for all sampling points are in the range from 0,89 to 1,77, which indicates the continuous and significant corrosive activity of water at all sampling point. The Risner index in all samples was in the range from 7.8 to 8.8, which indicates the significant pipeline corrosion. That is especially typical for the water from the well № 232, the Rizner index of which is 9.58, which indicates very intensive corrosion of the pipeline. Indicators rH2, for all samples, calculated both by F.U. Clarke and by the formula of A.I. Trufanov, indicate that the studied aquatic environment is very favorable for the vital activity of iron bacteria in general, and the pH - Eh zone of water samples indicates that there is an active vital activity of various strains: Leptothrix, Gallionella , Thiobacillus thiooxcidans or their combined activity. All the studied factors indicate that the most likely there is a complex genesis of corrosion processes in water supply networks, which combines both physicochemical and biological processes. This combination usually contributes to the processes of active secondary water pollution by the products of pipeline corrosion. Indicators rH2, for all samples, calculated by the formulas of F.U. Clark and of A.I. Trufanov, indicate that the studied aquatic environment is very favorable for the activity of iron bacteria in general, and the pH - Eh zone of water samples indicates that there is a rather high activity of different strains: Leptothrix, Gallionella, Thiobacillus thiooxcidans or their combined activity. The results of the research showed that for all ways to use of "SeaQuest Liquid" spicemen in the water of all sampling points there were no deviations from the standards of basic physicochemical parameters: the average pH of water was 7,67 ± 0.01, total water hardness was 4,3 ± 0,03, total alkalinity - 4,4 ± 0,05 mmol/dm,3 calcium content - 58,6 ± 0,7 mg/dm3, magnesium - 16,1 ± 0.2 mg/dm3, hydrocarbons - 261,4 ± 4,8 mg/dm3, manganese <0,01 mg/dm3, sulfates - 21,9 ± 1,2 mg/dm3, chlorides - 44,3 ± 1,4 mg/dm3, sodium and potassium - 44,0 ± 2,0 mg/dm3, residual chlorine - 0,35 ± 0,02 mg/dm3, ammonium - 0,2 ± 0.01 mg/dm3, permanganate oxidation - 2,3 ± 0,1 mgО2/dm3, nitrites - 0,09 ± 0,01 mg/dm3, nitrates - 1,53 ± 0,14 mg/dm3, total mineralization - 459,9 ± 15,1 mg/dm3. In some samples of water treated with “SeaQuest Liquid”, the iron content exceeded the hygienic standard (0,2 mg/dm3) and exceeded the maximum allowable level (1,0 mg/dm3). In drinking water samples, the levels of substances that are the part of "SeaQuest Liquid" specimen (polyphosphates, orthophosphates), varied at different sampling points but were within the normative values. The anticipated biological component of corrosion according to the calculated Rh2 index, was confirmed. In the presence of sulfate-reducing and thiobacteria in water, "SeaQuest Liquid" specimen increases the corrosion rate of steel by 2,9-7,2 times; subject to additional disinfection of water when treating with sodium hypochlorite, it reduces this indicator by 1,4-2,7 times. Under the action of "SeaQuest Liquid" in water treated with sodium hypochlorite, there was a decrease in the Langelier index: from -2,23 to -2,08 and from -1,79 to -1,70, indicating a decrease in its corrosive activity. In water untreated with sodium hypochlorite under the action of "SeaQuest Liquid" there was some increase in the Langelier index: from -1.80 to -1,95 and from -1,85 to -2,78; from -2,01 to -2,13, which indicates an increase in its corrosive aggressiveness.  Зазначено, що переважна більшість водопроводів діючих в Україні систем водопостачання виконані із сталі, або чавуну, які схильні до корозії. Встановлено, що одним із напрямків зниження корозійної агресивності питної води є застосування орто- поліфосфатного препарату "SeaQuest Liquid" (ТУ У 20.5-У 0502222-001:2017). Наведено результати досліджень впливу препарату “SeaQuest Liquid” на органолептичі та фізико-хімічні показники питної води. Визначено, що обробка водопровідної питної води препаратом “SeaQuest Liquid” не впливає на органолептичні показники, середні рівні яких упродовж 5-ти місяців спостережень практично не зазнавали суттєвих змін та знаходились в межах гігієнічних нормативів. У зразках води рівні речовин, що входять до складу препарату “SeaQuest Liquid” (поліфосфати, ортофосфати), перебували у межах нормативних значень. Якість води, обробленої ортополіфосфатним препаратом “SeaQuest Liquid”, за основними санітарно-хімічними показниками, окрім заліза, відповідає вимогам гігієнічних нормативів ДСанПіН 2.2.4.171-10. В окремих пробах води вміст заліза перевищував гігієнічний норматив (0,2 мг/дм3) та виходив за максимально допустимий рівень (1,0 мг/дм3). Під дією препарату “SeaQuest Liquid” у воді, яка оброблена гіпохлоритом натрію, спостерігалось зменшення індексу Ланжельє: з -2,23 до -2,08 і з -1,79 до -1,70, що свідчить про зниження її корозійної активності. У воді, не обробленій гіпохлоритом натрію, під впливом препарату  “SeaQuest Liquid” спостерігалось деяке зростання індексу Ланжельє: з -1,80 до -1,95  та з -1,85 до - 2,78;  з -2,01 до -2,13, що свідчить про зростання її корозійної агресивності. В умовах наявності у воді сульфатредукуючих  тіобактерій  препарат “SeaQuest Liquid” збільшує швидкість корозії сталі в 2,9-7,2 рази; за умови додаткового знезараження води гіпохлоритом натрію останній знижує цей показник в  1,4-2,7 рази

    An edge-to-edge Deployment Model for Pre-Congestion Notification: Admission Control over a DiffServ Region

    Get PDF
    This document describes a deployment model for pre-congestion notification (PCN) operating in a large DiffServ-based region of the Internet. PCN-based admission control protects the quality of service of existing flows in normal circumstances, whilst if necessary (eg after a large failure) pre-emption of some flows preserves the quality of service of the remaining flows. Each link has a configured-admission-rate and a configured-pre-emption-rate, and a router marks packets that exceed these rates. Hence routers give an early warning of their own potential congestion, before packets need to be dropped. Gateways around the edges of the PCN-region convert measurements of packet rates and their markings into decisions about whether to admit new flows, and (if necessary) into the rate of excess traffic that should be pre-empted. Per-flow admission states are kept at the gateways only, while the PCN markers that are required for all routers operate on the aggregate traffic - hence there is no scalability impact on interior routers
    corecore