458 research outputs found

    Design and operation of a prototype interaction point beam collision feedback system for the International Linear Collider

    Full text link
    A high-resolution, intratrain position feedback system has been developed to achieve and maintain collisions at the proposed future electron-positron International Linear Collider (ILC). A prototype has been commissioned and tested with a beam in the extraction line of the Accelerator Test Facility at the High Energy Accelerator Research Organization in Japan. It consists of a stripline beam position monitor (BPM) with analogue signal-processing electronics, a custom digital board to perform the feedback calculation, and a stripline kicker driven by a high-current amplifier. The closed-loop feedback latency is 148 ns. For a three-bunch train with 154 ns bunch spacing, the feedback system has been used to stabilize the third bunch to 450 nm. The kicker response is linear, and the feedback performance is maintained, over a correction range of over ±\pm60 {\mu}m. The propagation of the correction has been confirmed by using an independent stripline BPM located downstream of the feedback system. The system has been demonstrated to meet the BPM resolution, beam kick, and latency requirements for the ILC

    Passive SOBP generation from a static proton pencil beam using 3D-printed range modulators for FLASH experiments

    Get PDF
    The University Proton Therapy facility in Dresden (UPTD), Germany, is equipped with an experimental room with a beamline providing a static pencil beam. High proton beam currents can be achieved at this beamline which makes it suitable for FLASH experiments. However, the established experimental setup uses only the entrance channel of the proton Bragg curve. In this work, a set of 3D-printed range modulators designed to generate spread out Bragg peaks (SOBPs) for radiobiological experiments at ultra-high dose rate at this beamline is described. A new method to optimize range modulators specifically for the case of a static pencil beam based on the central depth dose profile is introduced. Modulators for two different irradiation setups were produced and characterized experimentally by measurements of lateral and depth dose distributions using different detectors. In addition, Monte Carlo simulations were performed to assess profiles of the dose averaged linear energy transfer (LETD) in water. These newly produced range modulators will allow future proton FLASH experiments in the SOBP at UPTD with two different experimental setups

    Precise Charm- and Bottom-Quark Masses: Theoretical and Experimental Uncertainties

    Full text link
    Recent theoretical and experimental improvements in the determination of charm and bottom quark masses are discussed. A new and improved evaluation of the contribution from the gluon condensate to the charm mass determination and a detailed study of potential uncertainties in the continuum cross section for bbˉb\bar b production is presented, together with a study of the parametric uncertainty from the αs\alpha_s-dependence of our results. The final results, mc(3GeV)=986(13)m_c(3 \text{GeV})=986(13) MeV and mb(mb)=4163(16)m_b(m_b)=4163(16) MeV, represent, together with a closely related lattice determination mc(3  GeV)=986(6)m_c(3\;{\rm GeV})=986(6) MeV, the presently most precise determinations of these two fundamental Standard Model parameters. A critical analysis of the theoretical and experimental uncertainties is presented.Comment: 12 pages, presented at Quarks~2010, 16th International Seminar of High Energy Physics, Kolomna, Russia, June 6-12, 2010; v2: references adde

    Analysis of the vector and axialvector BcB_c mesons with QCD sum rules

    Full text link
    In this article, we study the vector and axialvector BcB_c mesons with the QCD sum rules, and make reasonable predictions for the masses and decay constants, then calculate the leptonic decay widths. The present predictions for the masses and decay constants can be confronted with the experimental data in the future. We can also take the masses and decay constants as basic input parameters and study other phenomenological quantities with the three-point vacuum correlation functions via the QCD sum rules.Comment: 14 pages, 16 figure

    Prospect of making XPS a high throughput analytical method illustrated for a CuxNi1 xOy combinatorial material library

    Get PDF
    Combinatorial material science crucially depends on robust, high throughput characterization methods. While X ray photoelectron spectroscopy XPS may provide detailed information about chemical and electronic properties, it is a time consuming technique and, therefore, is not viewed as a high throughput method. Here we present preliminary XPS data of 169 measurement spots on a combinatorial 72 72 cm2 CuxNi1 amp; 8722;xOy compositional library to explore how characterization and evaluation routines can be optimized to improve throughput in XPS for combinatorial studies. In particular, two quantification approaches are compared. We find that a simple integration of XPS peak regions approach is suited for fast evaluation of, in the example system, the [Cu] [Cu] [Ni] ratio. Complementary to that, the time consuming XPS peak fit approach provides additional insights into chemical speciation and oxidation state changes, without a large deviation of the [Cu] [Cu] [Ni] ratio. This insight suggests exploiting the fast integration approach for real time analysis during XPS data collection, paving the way for an on the fly selection of points of interest i.e., areas on the sample where sudden composition changes have been identified for detailed XPS characterization. Together with the envisioned improvements when going from laboratory to synchrotron based excitation sources, this will shorten the analysis time sufficiently for XPS to become a realistic characterization option for combinatorial material scienc

    Widespread detection of highly pathogenic H5 influenza viruses in wild birds from the Pacific Flyway of the United States

    Get PDF
    A novel highly pathogenic avian influenza virus belonging to the H5 clade 2.3.4.4 variant viruses was detected in North America in late 2014. Motivated by the identification of these viruses in domestic poultry in Canada, an intensive study was initiated to conduct highly pathogenic avian influenza surveillance in wild birds in the Pacific Flyway of the United States. A total of 4,729 hunter-harvested wild birds were sampled and highly pathogenic avian influenza virus was detected in 1.3% (n = 63). Three H5 clade 2.3.4.4 subtypes were isolated from wild birds, H5N2, H5N8, and H5N1, representing the wholly Eurasian lineage H5N8 and two novel reassortant viruses. Testing of 150 additional wild birds during avian morbidity and mortality investigations in Washington yielded 10 (6.7%) additional highly pathogenic avian influenza isolates (H5N8 = 3 and H5N2 = 7). The geographically widespread detection of these viruses in apparently healthy wild waterfowl suggest that the H5 clade 2.3.4.4 variant viruses may behave similarly in this taxonomic group whereby many waterfowl species are susceptible to infection but do not demonstrate obvious clinical disease. Despite these findings in wild waterfowl, mortality has been documented for some wild bird species and losses in US domestic poultry during the first half of 2015 were unprecedented
    • …
    corecore