6 research outputs found

    Letter to the editor: Measles outbreak linked to an international dog show in Slovenia - primary cases and chains of transmission identified in Italy, November to December 2014

    Get PDF
    In the letter epidemiological and virological investigations on Italian measles cases associated to a measles outbreak in Slovenia, linked to an international dog show from 8 to 9 November 2014, are described

    Three-dimensional effects of an air curtain used to restrict cold room infiltration

    Get PDF
    The aim of this study was to compare the measured effectiveness of an air curtain device at different jet velocities against a three-dimensional (3-D) computational fluid dynamics (CFD) model. The air curtain device was not as wide as the entrance and had a geometry that encouraged 3-D flow. By carefully setting up the air curtain an effectiveness of 0.71 was achieved compared to the initial value of only 0.31 as set by the air curtain device installer. The 3-D CFD model predicted the infiltration through the entrance with no air curtain to an accuracy of within 20-32%. The predicted effectiveness, E, of the air curtain at different jet velocities was 0.10-0.15 lower than measured. The shape of the effectiveness curve against jet velocity was well predicted. CFD has shown that the flow from this air curtain cannot be considered as 2-D. The central part of the jet is deflected away from the cold store by the Coanda effect caused by the air curtain device's fan body. The edges of the jet are deflected into the cold store by the stack pressures and turn into the void caused by the deflected central jet. © 2006 Elsevier Inc. All rights reserved

    Three-dimensional effects of an air curtain used to restrict cold room infiltration

    Get PDF
    The aim of this study was to compare the measured effectiveness of an air curtain device at different jet velocities against a three-dimensional (3-D) computational fluid dynamics (CFD) model. The air curtain device was not as wide as the entrance and had a geometry that encouraged 3-D flow. By carefully setting up the air curtain an effectiveness of 0.71 was achieved compared to the initial value of only 0.31 as set by the air curtain device installer. The 3-D CFD model predicted the infiltration through the entrance with no air curtain to an accuracy of within 20-32%. The predicted effectiveness, E, of the air curtain at different jet velocities was 0.10-0.15 lower than measured. The shape of the effectiveness curve against jet velocity was well predicted. CFD has shown that the flow from this air curtain cannot be considered as 2-D. The central part of the jet is deflected away from the cold store by the Coanda effect caused by the air curtain device's fan body. The edges of the jet are deflected into the cold store by the stack pressures and turn into the void caused by the deflected central jet. (c) 2006 Elsevier Inc. All rights reserved

    Evidence of arbovirus co-infection in suspected febrile malaria and typhoid patients in Nigeria.

    No full text
    INTRODUCTION: Clinical symptoms of malaria and typhoid infections are virtually indistinguishable from those initially seen in many arbovirus infections. Here we describe arbovirus co-infection detected in 310 sera samples collected from febrile, clinically suspected malaria/typhoid patients in Borno State, Nigeria. METHODOLOGY: Tested initially for Plasmodium falciparum by microscopy and for Salmonella Typhi by Widal test, samples were subsequently tested for chikungunya (CHIKV), yellow fever (YFV), dengue (DENV) and West Nile viruses (WNV) by plaque reduction neutralization test. RESULTS: While 92% of patients tested positive for malaria, typhoid, an arbovirus infection, or a combination of one or more of these types of infections, less than 1% of the patients tested positive for malaria alone and only 3.9% tested positive for typhoid alone. Approximately half of the patients tested positive for infection with a single arbovirus (48%) regardless of the presence or absence of malaria or typhoid. Of those who showed 90% to 95% virus neutralization, 67.7% had neutralizing antibodies against DENV, 50% against CHIKV, 25% against WNV and 8.7% against YFV. Eight per cent tested negative against all six pathogens, suggesting that other arboviruses not tested for in this study may also be circulating in Nigeria. CONCLUSIONS: The results suggest that misdiagnosis of arbovirus co-infections as malaria infections, combined with a lack of virus surveillance and underreporting of arbovirus infections, increases the potential for undetected and uncontrolled spread of important vector-borne arboviruses becoming serious underlying public health concerns in Nigeria
    corecore