3 research outputs found
The application of hydrogen-palladium electrode for potentiometric acid-base determinations in tetrahydrofuran
The application of the hydrogen-palladium electrode (H2/Pd) as the indicator electrode for the determination of relative acidity scale (Es, mV) of tetrahydrofuran (THF) and the potentiometric titrations of acids in this solvent was investigated. The relative acidity scale tetrahydrofuran was determined from the difference half-neutralization potentials of perchloric acid and tetrabutylammonium hydroxide (TBAH), which were measured by using both H2/Pd-SCE and glass-SCE electrode pairs. The experimentally obtained value of Es scale THF with a H2/Pd-SCE electrode pair was 1155 mV, and those obtained with glass-SCE electrode pair 880 mV. By using a H2/Pd indicator electrode, the individual acids (benzoic acid, palmitic acid, maleic acid, acetyl acetone, α-naphthol) and two component acid mixtures (benzoic acid + α-naphthol, palmitic acid + α-naphthol, maleic acid + α-naphthol and maleic acid + ftalic acid) were titrated with a standard solution of TBAH. In addition, sodium methylate and potassium hydroxide proved to be very suitable titrating agents for titrating of the individual acids and the acids in mixtures, respectively. The relative error of the determination of acids in mixture was less than 3%. The results are in agreement with those obtained by a conventional glass electrode. The advantages of H2/Pd electrode over a glass electrode in potentiometric acid-base determinations in tetrahydrofuran lie in the following: this electrode gives wider relative acidity scale THF, higher the potential jumps at the titration end-point and relatively fast response time; furthermore, it is very durable, simple to prepare and can be used in the titrations of small volumes. [Projekat Ministarstva nauke Republike Srbije, br.172051
Coulometric-potentiometric determination of autoprotolysis constant and relative acidity scale of water
The autoprotolysis constant and relative acidity scale of water were determined by applying the coulometric-potentiometric method and a hydrogen/palladium (H2/Pd) generator anode. In the described procedure for the evaluation of autoprotolysis constant, a strong base generated coulometrically at the platinum cathode in situ in the electrolytic cell, in presence of sodium perchlorate as the supporting electrolyte, is titrated with hydrogen ions obtained by the anodic oxidation of hydrogen dissolved in palladium electrode. The titration was carried out with a glass-SCE electrode pair at 25.0±0.1°C. The value obtained pKw = 13.91 ± 0.06 is in agreement with literature data. The range of acidity scale of water is determined from the difference between the halfneutralization potentials of electrogenerated perchloric acid and that of sodium hydroxide in a sodium perchlorate medium. The halfneutralization potentials were measured using both a glass-SCE and a (H2/Pd)ind-SCE electrode pairs. A wider range of relative acidity scale of water was obtained with the glass-SCE electrode pair
JSCS–3769 Original scientific paper
Determination of relative acidity scales for some dipolar aprotic solvents by coulometry using a hydrogen–palladium electrod