54 research outputs found
Percutaneous Management of a Bronchobiliary Fistula after Radiofrequency Ablation in a Patient with Hepatocellular Carcinoma
Radiofrequency ablation (RFA) is a minimally invasive, image-guided procedure for the treatment of hepatic tumors. While RFA is associated with relatively low morbidity, sporadic bronchobiliary fistulae due to thermal damage may occur after RFA, although the incidence is rare. We describe a patient with a bronchobiliary fistula complicated by a liver abscess that occurred after RFA. This fistula was obliterated after placement of an external drainage catheter into the liver abscess for eight weeks
UARS MLS O3 soundings compared with lidar measurements using the conservative coordinates reconstruction technique
A technique based on conservative properties of certain
meteorological fields is used to compare ozone measurements
from the Microwave Limb Sounder (MLS) on the Upper Atmosphere
Research Satellite (UARS) with soundings from a lidar system
operated at midlatitudes by the University of
L'Aquila, Italy. A few typical cases are analyzed in connection
with the position of the vortex relative to the observing station,
and it is shown that in general lidar observations taken within
the vortex compare well with the UARS data,regardless of whether
they are coincident with a satellite overpass.It is shown that such
analysis may be useful for comparing measurements of the same quantity
taken at different sites using different measurement techniques.NASA, INGPublished1535-15381.8. Osservazioni di geofisica ambientaleJCR Journalope
NDSC Intercomparison of Stratospheric Aerosol Processing Algorithms
Scattering ratios R processed from the same raw data at 353 and 532 nm by different lidar groups agree within about 10 % for high and within about 4 % for low aerosol loading. In the main layer aerosol backscatter coefficients agree within about 30 % for high and within about 40 % for low aerosol loadingPublishedBerlin, Germany1.8. Osservazioni di geofisica ambientaleope
Sandwich holography for the diffusion process in a liquid solution
The suitability of sandwich holography for measurement of the diffusion coefficient in transparent liquid mixtures is demonstrated. Studies concerning the NaCI-water diffusion system are presented
Sandwich hologram for displacement derivative
The suitability of sandwich holography for displacement derivative measurement is demonstrated. Holographic carrier fringes are produced by shearing one plate relative to the other in a sandwich pair. Some experimental results are presented
PRELIMINARY RESULTS FROM THE OZONE LIDAR AT THE UNIVERSITY OF L'AQUILA
We describe the ozone lidar operated at the Department of Physics of the
Università dell'Aquila. Preliminary ozone profiles obtained with the DIAL
(Differential Absorption Lidar) technique are also reported and a comparison is made with ECC (Electro Chemical Cell) sonde data obtained at the FISBAT, CNR in Bologna. Although this comparison is of limited value
the two set of data show a good agreement. The influence on these measurements
of the recent detected volcanic aerosols from the eruption of Pinatubo are also
discussed.INGPublished651-6541.8. Osservazioni di geofisica ambientaleJCR Journalope
Esa-LITE Comparing University of L' Aquila aerosol lidar measurements with LITE data
During the NASA Lidar In-Space Technology Experiment (LITE) on the Space Shuttle in September 1994, the lidar Station of University of L' Aquila (SLAQ) was able to collect data in connection with two overpasses of LITE on September 11, 1994. We present these results within the stratospheric sounding activities of the SLAQ lidar systems.ESAPublishedIROE-CNR, Firenze, Italy1.8. Osservazioni di geofisica ambientaleope
Misure lidar di ozono ed aerosols stratosferici dopo l'eruzione del vulcano Pinatubo
Vengono riportati i risultati delle misure simultanee di ozono ed aerosol
stratosferici dopo l'eruzione del vulcano filippino Pinatubo effettuate
nella Stazione Lidar di L'Aquila nel periodo Agosto 1991-Marzo 1993.
L'analisi dei segnali lidar a tre lunghezze d'onda ha permesso sia di ricavare
le proprietà delle particelle presenti in statosfera sia di correggere i
profili di ozono dall'interferenza ottica dovuta alla presenza degli aerosol
stessi. Il confronto dei profili di ozono con quelli ottenuti in altri
siti con tecniche differenti mostra la validità del metodo utilizzato per
invertire i segnali DIAL.INGPublished31-381.8. Osservazioni di geofisica ambientaleope
The LIDAr station in L'Aquila: setup for the european polar campaign
A progress report of Ozone Lidar Station in L'Aquila (SLAQ) is presented. We extensively describe the experimental system and the recent upgrading; details about inversion of data are also given. We show some
preliminary ozone profiles which have been obtained at SLAQ and these measurements are discussed within the algorithm validation. In conclusion the data validation for the use in trajectory data analysis is also discussed.PublishedPorano1.8. Osservazioni di geofisica ambientaleope
- …