133 research outputs found

    All-optical modulation in a CMOS-compatible amorphous silicon-based device

    Get PDF
    Active silicon photonic devices, which dynamically control the flow of light, have received significant attention for their use in on-chip optical networks. High-speed active silicon photonic modulators and switches rely on the plasma dispersion effect, where a change in carrier concentration causes a variation in the refractive index. The necessary electron and hole concentration change can be introduced either by optical pumping, or by direct electrical injection and depletion. We demonstrate a fast photoinduced absorption effect in low loss hydrogenated amorphous silicon (a-Si:H) waveguides deposited at a temperature as low as 190°C. Significant modulation (M% ~90%) occurs with a 1 mm-long device. We attribute the enhanced modulation to the significantly larger free-carrier absorption effect of a-Si:H. The complementary metal-oxide semiconductor (CMOS) compatible technology of a-Si:H could be considered as a promising candidate to enable an easy back-end integration with standard microelectronics processes

    Field chemical immobilization of free-ranging crested porcupines with zoletil®: A reviewed dosage

    Get PDF
    The tiletamine-zolazepam mixture is a widely used anesthetic for chemical immobilization of wild mammals due to its short induction time, good muscle relaxation, smooth recovery with low convulsions occurrence, and minimal effect on respiration. An injection dose of 7–8 mg/kg of tiletamine-zolazepam has been proven to be an effective and safe immobilizing mixture for crested porcupines under field conditions. However, the occurrence of long immobilization and recovery times, with high excitement and convulsion during awakening, were recorded. In order to reduce such side effects after recovery, the effectiveness of a lower dosage (4–6 mg/kg) of tiletamine-zolazepam (Zoletil® ) was tested. The results obtained confirm that the use of tiletamine-zolazepam in crested porcupine immobilization provides a quick induction, wide safety margin, and predictable awakening under field conditions. A smaller injection dosage of 5 mg/kg has been proven to be sufficient to ensure a short induction time (average: 7.1 min), with good muscle relaxation and little excitement of the animals during awakening. The lower dosage of tiletamine-zolazepam, while providing a shorter recovery time (average: 53.6 min), proves to be adequate for standard handling procedures. Furthermore, the smaller amount of tiletamine-zolazepam also ensures safe immobilization for pregnant individuals and porcupettes

    Surface Air-Pressure Measurements From Space Using Differential Absorption Radar on the Right Wing of the 60 GHz Oxygen Band

    Get PDF
    Abstract Surface air pressure is one of the most important parameters used in Numerical Weather Prediction (NWP) models. Although it has been measured using weather stations on the ground for many decades, the numbers of measurements are sparse and concentrated on land. Few measurements from buoys and ships are available over ocean. Global measurements can only be achieved by using remote sensing from Space, which is challenging; however, a novel design using Differential Absorption Radar (DAR) can provide a potential solution. The technique relies on two facts: first the electromagnetic fields are absorbed mainly by oxygen and water vapor, and second that oxygen is well mixed. In this work we discuss a space-borne concept, which aims at providing, over the ocean, consistent, and regular observations for determining surface air pressure from space by a design of a multi-tone radar operating on the upper wing of the O2 absorption band with tones from 64 to 70 GHz. Simulations of radar vertical profiles based on the output of a state of-the-art microphysical retrievals applied to the A-Train suite of sensors are exploited to establish the performance of such a system for surface pressure determination. In particular the identification and quantification of errors introduced by the presence of water vapor, cloud liquid water and rain water and the potential of a correction via the three-tone method is discussed. Errors introduced by surface measurement noise and temperature profile uncertainties are discussed as well. Results show that accuracy between 2 and 5 hPa is at reach

    Hematological and serum biochemistry values in free-ranging crested porcupine

    Get PDF
    The crested porcupine is a widespread naturalized Italian rodent of African origin; nevertheless, very little information on the population abundance and its health status is available. In this study, the hematological and serum chemistry profile of 10 free-ranging captured crested porcupines was established for the first time. The mean hematological values resulted: 5.7 SD 0.4 M/μL for red blood cells; 13.6 SD 0.8 g/dL for hemoglobin; 77.3 SD 5.7 fL for mean corpuscular volume and 30.1 SD 4.7 g/dL for mean corpuscular hemoglobin concentration; 14.4 SD 7.2 K/μL for white blood cells; and 557.0 SD 469.9 K/μL for platelets. The mean urea and creatinine values resulted with 19.8 SD 8.3 mg/dL and 1.6 SD 3.0 mg/dL, respectively. The mean value of total protein was 6.7 SD 1.0 g/dL, with values of albumin higher than globulins. The mean activity of creatine kinase, aspartate transaminase, gamma-glutamyl transpeptidase, and alkaline phosphatase was 927.3 SD 607.6 U/L, 199.2 SD 70.8 U/L, 16.9 SD 13.7 U/L, and 256 SD 75.8 U/L, respectively. Highest values of alkaline phosphatase were recorded in two porcupines presenting severe injuries with clear signs of infection. These preliminary results may be a helpful tool in order to assess porcupine health status

    Heart Rate Variability Dynamics for the Prognosis of Cardiovascular Risk

    Get PDF
    Statistical, spectral, multi-resolution and non-linear methods were applied to heart rate variability (HRV) series linked with classification schemes for the prognosis of cardiovascular risk. A total of 90 HRV records were analyzed: 45 from healthy subjects and 45 from cardiovascular risk patients. A total of 52 features from all the analysis methods were evaluated using standard two-sample Kolmogorov-Smirnov test (KS-test). The results of the statistical procedure provided input to multi-layer perceptron (MLP) neural networks, radial basis function (RBF) neural networks and support vector machines (SVM) for data classification. These schemes showed high performances with both training and test sets and many combinations of features (with a maximum accuracy of 96.67%). Additionally, there was a strong consideration for breathing frequency as a relevant feature in the HRV analysis

    Heart Rate Variability Dynamics for the Prognosis of Cardiovascular Risk

    Get PDF
    Statistical, spectral, multi-resolution and non-linear methods were applied to heart rate variability (HRV) series linked with classification schemes for the prognosis of cardiovascular risk. A total of 90 HRV records were analyzed: 45 from healthy subjects and 45 from cardiovascular risk patients. A total of 52 features from all the analysis methods were evaluated using standard two-sample Kolmogorov-Smirnov test (KS-test). The results of the statistical procedure provided input to multi-layer perceptron (MLP) neural networks, radial basis function (RBF) neural networks and support vector machines (SVM) for data classification. These schemes showed high performances with both training and test sets and many combinations of features (with a maximum accuracy of 96.67%). Additionally, there was a strong consideration for breathing frequency as a relevant feature in the HRV analysis

    Analysis of baseline redundancy in synthetic aperture interferometric radiometers

    No full text
    The performance of spaceborne instruments based on synthetic aperture interferometric radiometry, which have been proposed in recent years for microwave passive imaging applications, is reviewed. The main focus is on the improvement of the radiometric resolution obtained through the so-called technique of baseline redundancy, which is achieved through appropriate positioning of antenna elements over the geometrical antenna array configuration
    corecore