95 research outputs found

    Ventricular Volume Load Reveals the Mechanoelastic Impact of Communicating Hydrocephalus on Dynamic Cerebral Autoregulation.

    Get PDF
    Several studies have shown that the progression of communicating hydrocephalus is associated with diminished cerebral perfusion and microangiopathy. If communicating hydrocephalus similarly alters the cerebrospinal fluid circulation and cerebral blood flow, both may be related to intracranial mechanoelastic properties as, for instance, the volume pressure compliance. Twenty-three shunted patients with communicating hydrocephalus underwent intraventricular constant-flow infusion with Hartmann's solution. The monitoring included transcranial Doppler (TCD) flow velocities (FV) in the middle (MCA) and posterior cerebral arteries (PCA), intracranial pressure (ICP), and systemic arterial blood pressure (ABP). The analysis covered cerebral perfusion pressure (CPP), the index of pressure-volume compensatory reserve (RAP), and phase shift angles between Mayer waves (3 to 9 cpm) in ABP and MCA-FV or PCA-FV. Due to intraventricular infusion, the pressure-volume reserve was exhausted (RAP) 0.84+/-0.1 and ICP was increased from baseline 11.5+/-5.6 to plateau levels of 20.7+/-6.4 mmHg. The ratio dRAP/dICP distinguished patients with large 0.1+/-0.01, medium 0.05+/-0.02, and small 0.02+/-0.01 intracranial volume compliances. Both M wave phase shift angles (r = 0.64; p<0.01) and CPP (r = 0.36; p<0.05) displayed a gradual decline with decreasing dRAP/dICP gradients. This study showed that in communicating hydrocephalus, CPP and dynamic cerebral autoregulation in particular, depend on the volume-pressure compliance. The results suggested that the alteration of mechanoelastic characteristics contributes to a reduced cerebral perfusion and a loss of autonomy of cerebral blood flow regulation. Results warrant a prospective TCD follow-up to verify whether the alteration of dynamic cerebral autoregulation may indicate a progression of communicating hydrocephalus.Alexander-von-Humboldt foundation, Cambridge Enterprise Ltd.This is the final version of the article. It first appeared from the Public Library of Science via http://dx.doi.org/10.1371/journal.pone.015850

    Investigation of the hydrodynamic properties of a new MRI-resistant programmable hydrocephalus shunt.

    Get PDF
    BACKGROUND: The Polaris valve is a newly released hydrocephalus shunt that is designed to drain cerebrospinal fluid (CSF) from the brain ventricles or lumbar CSF space. The aim of this study was to bench test the properties of the Polaris shunt, independently of the manufacturer. METHODS: The Polaris Valve is a ball-on-spring valve, which can be adjusted magnetically in vivo. A special mechanism is incorporated to prevent accidental re-adjustment by an external magnetic field. The performance and hydrodynamic properties of the valve were evaluated in the UK Shunt Evaluation Laboratory, Cambridge, UK. RESULTS: The three shunts tested showed good mechanical durability over the 3-month period of testing, and a stable hydrodynamic performance over 45 days. The pressure-flow performance curves, operating, opening and closing pressures were stable. The drainage rate of the shunt increased when a negative outlet pressure (siphoning) was applied. The hydrodynamic parameters fell within the limits specified by the manufacturer and changed according to the five programmed performance levels. Hydrodynamic resistance was dependant on operating pressure, changing from low values of 1.6 mmHg/ml/min at the lowest level to 11.2 mmHg/ml/min at the highest performance level. External programming proved to be easy and reliable. Even very strong magnetic fields (3 Tesla) were not able to change the programming of the valve. However, distortion of magnetic resonance images was present. CONCLUSION: The Polaris Valve is a reliable, adjustable valve. Unlike other adjustable valves (except the Miethke ProGAV valve), the Polaris cannot be accidentally re-adjusted by an external magnetic field.RIGHTS : This article is licensed under the BioMed Central licence at http://www.biomedcentral.com/about/license which is similar to the 'Creative Commons Attribution Licence'. In brief you may : copy, distribute, and display the work; make derivative works; or make commercial use of the work - under the following conditions: the original author must be given credit; for any reuse or distribution, it must be made clear to others what the license terms of this work are

    Influence of general anaesthesia on slow waves of intracranial pressure.

    Get PDF
    OBJECTIVE: Slow vasogenic intracranial pressure (ICP) waves are spontaneous ICP oscillations with a low frequency bandwidth of 0.3-4 cycles/min (B-waves). B-waves reflect dynamic oscillations in cerebral blood volume associated with autoregulatory cerebral vasodilation and vasoconstriction. This study quantifies the effects of general anaesthesia (GA) on the magnitude of B-waves compared to natural sleep and conscious state. MATERIALS AND METHODS: The magnitude of B-waves was assessed in 4 groups of 30 patients each with clinical indications for ICP monitoring. Normal pressure hydrocephalus patients undergoing Cerebrospinal Fluid (CSF) infusion studies in the conscious state (GROUP A) and under GA (GROUP B), and hydrocephalus patients undergoing overnight ICP monitoring during physiological sleep (GROUP C) were compared to deeply sedated traumatic brain injury (TBI) patients with well-controlled ICP during the first night of Intensive Care Unit (ICU) stay (GROUP D). RESULTS: A total of 120 patients were included. During CSF infusion studies, the magnitude of slow waves was higher in conscious patients ( GROUP A: 0.23+/-0.10 mm Hg) when compared to anaesthetised patients ( GROUP B: 0.15+/-0.10 mm Hg; p = 0.011). Overnight magnitude of slow waves was higher in patients during natural sleep (GROUP C: 0.20+/-0.13 mm Hg) when compared to TBI patients under deep sedation (GROUP D: 0.11+/- 0.09 mm Hg; p = 0.002). CONCLUSION: GA and deep sedation are associated with a reduced magnitude of B-waves. ICP monitoring carried out under GA is affected by iatrogenic suppression of slow vasogenic waves of ICP. Accounting for the effects of anaesthesia on vasogenic waves may prevent the misidentification of potential shunt-responders as non-responders.This is the author accepted manuscript. The final version is available from Taylor & Francis via http://dx.doi.org/10.1080/01616412.2016.1189200
    • …
    corecore