18 research outputs found

    Endotoxin exposure and changes in short-term pulmonary function among sewage workers

    Full text link
    Objectives: The inhaled endotoxin is considered as a causative factor in the process of acute bronchial obstruction, which can be measured by a decrease in forced expiratory volume in 1 s (FEV1). The aim of this study was to assess endotoxin exposure among sewage treatment plant workers (STPW) and its effect on across-shift changes in respiratory airflow. Material and Methods: A group of 78 STPW from a large sewage treatment plant was studied. Inhalable dust for endotoxin assessment was collected using personal aerosol samplers. Endotoxin was assayed with the kinetic, chromogenic Limulus amebocyte lysate test. Across-shift spirometric measurements were performed on Mondays, after 2-days absence from work, with the use of portable spirometer. The forced vital capacity (FVC), and FEV1 parameters were analyzed. Multifactor regression modeling was performed to determine parameters significantly associated with endotoxin exposure. Results: The concentration of inhalable dust and endotoxin ranged from 0.01–1.38 mg/m3 and 0.68–214 endotoxin units per cubic meter of air (EU/m3), respectively. Endotoxins were characterized with the skewed distribution (arithmetic mean (AM) = 38.8 EU/m3, geometric mean (GM) = 15.4 EU/m3, geometric standard deviation (GSD) = 4.21). Through the use of multifactor analysis, which excluded the main confounders (inhalable dust and smoking habit) it was found that, despite low levels of endotoxin, it had significant impact on the observed across-shift decline in FEV1 (p = 0.044). For this parameter, the regression slope was additionally calculated (r = –0.017, p = 0.071). Conclusions: Relatively low levels of endotoxin among sewage treatment plant workers may cause small, but significant across-shift declines in FEV1. The observed relationship was independent of organic dust concentrations and smoking habit. The respiratory protection should be provided for STPW

    Indoor allergens in settled dust from kindergartens in city of Łódź, Poland

    Full text link
    Objectives: The main objective of the study was to determine the levels of house dust mite (Der p1), dog (Can f1), cat (Fel d1) and cockroach (Bla g2) allergens in kindergartens localized in an urban agglomeration. Material and Methods: A quantitative analysis of allergens was carried out in settled dust samples collected by vacuuming the floor surface in three kindergartens (N = 84) and children's clothing (N = 36). The samples were collected in springsummer and autumn-winter periods as well as at the beginning and end of the week. The allergen dust concentration was determined by enzyme-linked immunoenzymatic assay (ELISA). Results: The mean geometric concentrations (±geometric standard deviations) of allergens Der p1, Can f1, Fel d1 and Bla g2 determined in kindergartens were: 0.02±3.21 μg/g of dust; 0.97±4.49 μg/g of dust; 0.30±4.43 μg/g of dust and 0.01±3.08 μg/g of dust, respectively. Younger classrooms (children aged from 3 to 4 years) were characterized by almost twice higher mean concentration of allergen Fel d1, as compared to older classrooms (children aged from 5 to 6 years) (p < 0.05). A significant impact of seasonality on the level of dog allergen Can f1 was found (p < 0.05). No significant weekly variation was found in average concentrations of the allergens. Children who had a dog and/or cat at home were characterized by high concentrations of allergens Can f1 and Fel d1 on their clothes (59.2±5.39 μg Can f1/g of dust; 3.63±1.47 μg Fel d1/g of dust), significantly higher than concentrations of allergens in children who did not have any pets (p < 0.001). Conclusions: Special attention should be paid to keeping the kindergarten rooms tidy and clean and to an appropriate choice of furnishings and fittings which would prevent the proliferation of the house dust mite and accumulation of allergens

    Harmful biological agents in municipal waste thermal treatment plants

    No full text
    Solid waste storage in specially designated areas – landfills – has been the basic method of municipal solid waste disposal management for many years. However, thermal treatment is the currently preferred method of solid waste disposal. Hygienic assessment of working conditions in municipal waste incineration plants is hindered due to the variability and complexity of pollutants emitted during the combustion process. For many years studies describing this problem have focused mainly on chemical pollution inside the plants as well as emitted into the atmosphere. Available data indicates the presence of organic dust at workplaces in the range 0.1–14 mg/m 3 . It has been proven that it is a carrier of a wide spectrum of microorganisms, including bacteria, fungi and both mesophilic and thermophilic actinomycetes as well as adenoviruses and torque teno virus (TTV). In the air, at workplaces, bacterial endotoxins have also been found in concentrations reaching even 50 000 EU/m 3 , which may significantly affect the occurrence of pro-inflammatory reactions in the lungs as well as toxic pneumonitis. Biological agents should be taken into account in the occupational risk assessment for harmful agents present in this environment, and an in-depth characterization of exposure and health effects resulting from contact with these agents should be continued to an even greater extent than before. Med Pr. 2019;70(1):99–10

    Airborne peptidoglycans as a supporting indicator of bacterial contamination in a metal processing plant

    No full text
    Objectives: The aim of this study was to assess exposure to airborne endotoxins and peptidoglycans (PGs) as well as possibility of using PGs as a surrogate measure of bacterial exposure in workplaces in a metal processing plant. Material and Methods: Personal dosimetry (N = 11) was used to obtain data on concentrations of viable bacteria, total number of bioaerosol particles, endotoxins and peptidoglycans. To investigate the size distributions of aerosol particles responsible for transport of endotoxins and PGs, air samples (N = 5) were additionally collected using the 8-stage cascade impactor. Endotoxins and PGs were assayed with the Limulus amebocyte lysate (LAL) test and a kinetic version of the silkworm larvae plasma (SLP) test, respectively. Results: Median concentrations of airborne PGs (14.6 ng/m3), endotoxins (0.2 ng/m3), viable bacteria (1.16×103 CFU/m3) and the total number of bioaerosol particles (1.81×106 cells/m3) were determined. Qualitative analysis revealed presence of 19 bacterial species belonging to 14 genera. The calculations showed strong, significant correlations (p < 0.05) between endotoxins, viable bacteria (r = 0.75) and the total number of bioaerosol particle concentrations (r = 0.76) as well as between PGs and the total number of bioaerosol particle concentrations (r = 0.72). Size distribution analysis showed that the highest concentrations of bacterial aerosols occurred in the range of 2.1–3.3 μm. In the case of endotoxins, an increase of concentrations in 2 ranges of aerodynamic diameters: 1.1–3.3 μm and 5.8–9 μm was shown. For PGs there was a visible gradual increase of their concentrations in the range 2.1–9 μm. Conclusions: Peptidoglycans can be treated as a supporting indicator of bacterial contamination in metal processing plants, particularly when an assessment of an immunotoxic potential of microbiological hazards needs to be performed. However, to be extrapolated to other occupational and non-occupational environments, the obtained results require a further verification

    Indoor allergens in settled dust from kindergartens in city of Łódź, Poland

    No full text
    Objectives: The main objective of the study was to determine the levels of house dust mite (Der p1), dog (Can f1), cat (Fel d1) and cockroach (Bla g2) allergens in kindergartens localized in an urban agglomeration. Material and Methods: A quantitative analysis of allergens was carried out in settled dust samples collected by vacuuming the floor surface in three kindergartens (N = 84) and children's clothing (N = 36). The samples were collected in springsummer and autumn-winter periods as well as at the beginning and end of the week. The allergen dust concentration was determined by enzyme-linked immunoenzymatic assay (ELISA). Results: The mean geometric concentrations (±geometric standard deviations) of allergens Der p1, Can f1, Fel d1 and Bla g2 determined in kindergartens were: 0.02±3.21 μg/g of dust; 0.97±4.49 μg/g of dust; 0.30±4.43 μg/g of dust and 0.01±3.08 μg/g of dust, respectively. Younger classrooms (children aged from 3 to 4 years) were characterized by almost twice higher mean concentration of allergen Fel d1, as compared to older classrooms (children aged from 5 to 6 years) (p < 0.05). A significant impact of seasonality on the level of dog allergen Can f1 was found (p < 0.05). No significant weekly variation was found in average concentrations of the allergens. Children who had a dog and/or cat at home were characterized by high concentrations of allergens Can f1 and Fel d1 on their clothes (59.2±5.39 μg Can f1/g of dust; 3.63±1.47 μg Fel d1/g of dust), significantly higher than concentrations of allergens in children who did not have any pets (p < 0.001). Conclusions: Special attention should be paid to keeping the kindergarten rooms tidy and clean and to an appropriate choice of furnishings and fittings which would prevent the proliferation of the house dust mite and accumulation of allergens

    Distribution of Selected Drug-resistant Enterococcus Species in Meat Plants in Poland

    No full text
    This study aimed to assess the prevalence of enterococci (including vancomycin-resistant, VRE) strains in meat plants and evaluate their biofilm-forming potential. In two Polish meat plants, 75 samples of raw pork meat, swabs from work surfaces (floors, tables, machine parts and tools) and employees’ hands were collected. The analyses indicated that enterococci were present in more than 72% of the tested samples. In addition, VRE isolates were found in more than 25% of the tested samples (especially in cutting and processing rooms). VRE strains of Enterococcus faecium and E. faecalis were resistant to penicillin, ampicillin, erythromycin, and rifampicin. Moreover, 77% of E. faecium and 43% of E. faecalis isolates showed biofilm-forming ability. The observed high biofilm-forming potential among the analyzed VRE strains indicates that these agents may play an essential role in spreading drug resistance in the food chain through contaminated surfaces, meat, and workers’ hands

    Endotoxin exposure and changes in short-term pulmonary function among sewage workers

    No full text
    Objectives: The inhaled endotoxin is considered as a causative factor in the process of acute bronchial obstruction, which can be measured by a decrease in forced expiratory volume in 1 s (FEV1). The aim of this study was to assess endotoxin exposure among sewage treatment plant workers (STPW) and its effect on across-shift changes in respiratory airflow. Material and Methods: A group of 78 STPW from a large sewage treatment plant was studied. Inhalable dust for endotoxin assessment was collected using personal aerosol samplers. Endotoxin was assayed with the kinetic, chromogenic Limulus amebocyte lysate test. Across-shift spirometric measurements were performed on Mondays, after 2-days absence from work, with the use of portable spirometer. The forced vital capacity (FVC), and FEV1 parameters were analyzed. Multifactor regression modeling was performed to determine parameters significantly associated with endotoxin exposure. Results: The concentration of inhalable dust and endotoxin ranged from 0.01–1.38 mg/m3 and 0.68–214 endotoxin units per cubic meter of air (EU/m3), respectively. Endotoxins were characterized with the skewed distribution (arithmetic mean (AM) = 38.8 EU/m3, geometric mean (GM) = 15.4 EU/m3, geometric standard deviation (GSD) = 4.21). Through the use of multifactor analysis, which excluded the main confounders (inhalable dust and smoking habit) it was found that, despite low levels of endotoxin, it had significant impact on the observed across-shift decline in FEV1 (p = 0.044). For this parameter, the regression slope was additionally calculated (r = –0.017, p = 0.071). Conclusions: Relatively low levels of endotoxin among sewage treatment plant workers may cause small, but significant across-shift declines in FEV1. The observed relationship was independent of organic dust concentrations and smoking habit. The respiratory protection should be provided for STPW

    Microbial Air Quality in Municipal Buses Before and After Disinfection of their Air-Conditioning Systems

    No full text
    To ensure the proper quality of the air and simultaneously improve the comfort of professional drivers or travellers, the cars are fit with air-conditioning (AC) systems. The AC installations, however, quite often create suitable conditions for the development of microbiological agents and become an active emission source of harmful bioaerosols. This study was carried out in 6 municipal buses in large city located in central Poland. In studied vehicles, ozonisation or manual application of chemical disinfectant in a spray form were used for disinfection of AC bus systems. The concentrations of bacteria and fungi in the air collected in buses before the service of their AC installations were 4.3×102 CFU/m3 and 2.4×102 CFU/m3, respectively. After AC service using both tested disinfection methods, the decrease in microbial concentrations in the air of municipal buses was observed. The highest effectiveness of AC cleaning was noted when the chemical disinfectant in a spray form was used. This study revealed that to eliminate microbiological contamination and, by that, decrease the exposure of both drivers and passengers to harmful microbial contaminants, the chemical disinfection of bus AC system should be performed at regular basis

    Fibers as carriers of microbial particles

    No full text
    Background: The aim of the study was to assess the ability of natural, synthetic and semi-synthetic fibers to transport microbial particles. Material and Methods: The simultaneously settled dust and aerosol sampling was carried out in 3 industrial facilities processing natural (cotton, silk, flax, hemp), synthetic (polyamide, polyester, polyacrylonitrile, polypropylene) and semi-synthetic (viscose) fibrous materials; 2 stables where horses and sheep were bred; 4 homes where dogs or cats were kept and 1 zoo lion pavilion. All samples were laboratory analyzed for their microbiological purity. The isolated strains were qualitatively identified. To identify the structure and arrangement of fibers that may support transport of microbial particles, a scanning electron microscopy analysis was performed. Results: Both settled and airborne fibers transported analogous microorganisms. All synthetic, semi-synthetic and silk fibers, present as separated threads with smooth surface, were free from microbial contamination. Natural fibers with loose packing and rough surface (e.g., wool, horse hair), sheaf packing and septated surface (e.g., flax, hemp) or present as twisted ribbons with corrugated surface (cotton) were able to carry up to 9×105 cfu/g aerobic bacteria, 3.4×104 cfu/g anaerobic bacteria and 6.3×104 cfu/g of fungi, including pathogenic strains classified by Directive 2000/54/EC in hazard group 2. Conclusions: As plant and animal fibers are contaminated with a significant number of microorganisms, including pathogens, all of them should be mechanically eliminated from the environment. In factories, if the manufacturing process allows, they should be replaced by synthetic or semi-synthetic fibers. To avoid unwanted exposure to harmful microbial agents on fibers, the containment measures that efficiently limit their presence and dissemination in both occupational and non-occupational environments should be introduced. Med Pr 2015;66(4):511–52
    corecore