4 research outputs found

    Preparation of rat sciatic nerve for ex vivo neurophysiology

    No full text
    Ex vivo preparations enable the study of many neurophysiological processes in isolation from the rest of the body while preserving local tissue structure. This work describes the preparation of rat sciatic nerves for ex vivo neurophysiology, including buffer preparation, animal procedures, equipment setup and neurophysiological recording. This work provides an overview of the different types of experiments possible with this method. The outlined method aims to provide 6 h of stimulation and recording on extracted peripheral nerve tissue in tightly controlled conditions for optimal consistency in results. Results obtained using this method are A-fibre compound action potentials (CAP) with peak-to-peak amplitudes in the millivolt range over the entire duration of the experiment. CAP amplitudes and shapes are consistent and reliable, making them useful to test and compare new electrodes to existing models, or the effects of interventions on the tissue, such as the use of chemicals, surgical alterations, or neuromodulatory stimulation techniques. Both conventional commercially available cuff electrodes with platinum-iridium contacts and custom-made conductive elastomer electrodes were tested and gave similar results in terms of nerve stimulus strength-duration response

    Conductive elastomer composites for fully polymeric, flexible bioelectronics

    Get PDF
    Flexible polymeric bioelectronics have the potential to address the limitations of metallic electrode arrays by minimizing the mechanical mismatch at the device-tissue interface for neuroprosthetic applications. This work demonstrates the straightforward fabrication of fully organic electrode arrays based on conductive elastomers (CEs) as a soft, flexible and stretchable electroactive composite material. CEs were designed as hybrids of polyurethane elastomers (PU) and poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS), with the aim of combining the electrical properties of PEDOT:PSS with the mechanical compliance of elastomers. CE composites were fabricated by solvent casting of PEDOT:PSS dispersed in dissolved PU at different conductive polymer (CP) loadings, from 5 wt% to 25 wt%. The formation of PEDOT:PSS networks within the PU matrix and the resultant composite material properties were examined as a function of CP loading. Increased PEDOT:PSS loading was found to result in a more connected network within the PU matrix, resulting in increased conductivity and charge storage capacity. Increased CP loading was also determined to increase the Young's modulus and reduce the strain at failure. Biological assessment of CE composites showed them to mediate ReNcell VM human neural precursor cell adhesion. The increased stiffness of CE films was also found to promote neurite outgrowth. CE sheets were directly laser micromachined into a functional array and shown to deliver biphasic waveforms with comparable voltage transients to Pt arrays in in vitro testing

    Surface electromyography using dry polymeric electrodes.

    Get PDF
    Conventional wet Ag/AgCl electrodes are widely used in electrocardiography, electromyography (EMG), and electroencephalography (EEG) and are considered the gold standard for biopotential measurements. However, these electrodes require substantial skin preparation, are single use, and cannot be used for continuous monitoring (>24 h). For these reasons, dry electrodes are preferable during surface electromyography (sEMG) due to their convenience, durability, and longevity. Dry conductive elastomers (CEs) combine conductivity, flexibility, and stretchability. In this study, CEs combining poly(3,4-ehtylenedioxythiophene):polystyrenesulfonate (PEDOT:PSS) in polyurethane are explored as dry, skin contacting EMG electrodes. This study compares these CE electrodes to commercial wet Ag/AgCl electrodes in five subjects, classifying four movements: open hand, fist, wrist extension, and wrist flexion. Classification accuracy is tested using a backpropagation artificial neural network. The control Ag/AgCl electrodes have a 98.7% classification accuracy, while the dry conductive elastomer electrodes have a classification accuracy of 99.5%. As a conclusion, PEDOT based dry CEs were shown to successfully function as on-skin electrodes for EMG recording, matching the performance of Ag/AgCl electrodes, while addressing the need for minimal skin prep, no gel, and wearable technology
    corecore