35 research outputs found
Does urethral competence affect urodynamic voiding parameters in women with prolapse?
Aims To (1) compare voiding parameters and (2) correlate symptoms and urodynamic findings in women with pelvic organ prolapse (POP) and varying degrees of urethral competence. Methods We compared three groups of women with stages II–IV POP. Groups 1 and 2 were symptomatically stress continent women participating in the Colpopexy and Urinary Reduction Efforts (CARE) trial; during prolapse reduction before sacrocolpopexy, Group 1 (n = 67) did not have and Group 2 (n = 84) had urodynamic stress incontinence (USI) during prolapse reduction. Group 3 participants (n = 74), recruited specifically for this study, had stress urinary incontinence (SUI) symptoms and planned sacrocolpopexy. Participants completed standardized uroflowmetry, pressure voiding studies, and validated symptom questionnaires. Results Subjects' median age was 61 years, median parity 3 and 87% had stage III or IV POP. Fourteen percent of women in Group 3 demonstrated USI without, and 70% with, prolapse reduction. Women in Groups 2 and 3 had more detrusor overactivity (DO) than Group 1 (17 and 24% vs. 6%, P = 0.02) and detrusor overactivity incontinence (DOI) (15 and 8% vs. 0%, P = 0.004). Based on the Blaivis–Groutz nomogram, 60% of all women were obstructed. Post-void residual volume (PVR), peak flow rate, detrusor pressure at peak flow, voiding mechanisms, voiding patterns, obstruction and urinary retention did not differ among groups. Women in Group 3 had higher irritative and obstructive symptom scores than Group 1 or 2; neither score differed by presence of DO nor obstruction, respectively. Conclusion Women with POP have significant rates of urodynamic obstruction and retention, independent of their continence status. Symptoms of obstruction and retention correlate poorly with urodynamic findings. Neurourol. Urodynam. 26:1030–1035, 2007. © 2007 Wiley-Liss, Inc.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/57365/1/20436_ftp.pd
Hidden Silicon-Vacancy Centers in Diamond
We characterize a high-density sample of negatively charged silicon-vacancy
(SiV) centers in diamond using collinear optical multidimensional coherent
spectroscopy. By comparing the results of complementary signal detection
schemes, we identify a hidden population of \ce{SiV^-} centers that is not
typically observed in photoluminescence, and which exhibits significant
spectral inhomogeneity and extended electronic times. The phenomenon is
likely caused by strain, indicating a potential mechanism for controlling
electric coherence in color-center-based quantum devices
Two-Year Outcomes After Sacrocolpopexy With and Without Burch to Prevent Stress Urinary Incontinence
To report anatomic and functional outcomes 2 years after sacrocolpopexy in stress-continent women with or without prophylactic Burch colposuspension
Racial Differences in Pelvic Anatomy by Magnetic Resonance Imaging
To use static and dynamic magnetic resonance imaging (MRI) to compare dimensions of the bony pelvis and soft tissue structures in a sample of African-American and white women
Risk factors for mesh/suture erosion following sacral colpopexy
To identify risks for mesh/suture erosions following sacrocolpopexy (ASC)
Magnetic resonance assessment of pelvic anatomy and pelvic floor disorders after childbirth
To compare pelvic anatomy, using magnetic resonance imaging (MRI), between women with or without pelvic floor disorders 6-12 months after a first delivery
Enhancing Participation of Older Women in Surgical Trials
Older participants are often excluded from clinical trials, precluding a representative sample
A multicentered comparison of measurements obtained with microtip and external water pressure transducers
This study compared simultaneous intravesical pressure readings obtained with catheter-mounted microtip transducers and external water pressure transducer catheters during filling cystometry. Women undergoing multichannel urodynamic testing were randomly assigned to one of three groups: two microtip catheters, two external water pressure transducer catheters, or one of each type. Intravesical pressure was measured simultaneously for each transducer combination in each subject for minimal and maximal Valsalva effort and minimal, moderate, and maximal cough effort at two sequential bladder volumes (150 and 300 ml). Paired t tests were used to compare the means of the intravesical pressure obtained by the two types of catheters. The largest mean differences were observed when comparing microtip and water pressure transducers. Correlations of maximum pressure were consistently high between two microtip transducers and two water pressure transducers but lower for the microtip–water combination. Excellent reproducibility was demonstrated with transducers of similar types for intravesical pressures recorded during Valsalva and cough in women without prolapse. However, considerable variability was seen in pressures recorded by different transducers, particularly dependent on the water catheter manufacturer, indicating that intravesical pressure recordings from microtip and water-based systems are not interchangeable.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/45850/1/192_2005_Article_27.pd