22 research outputs found

    A Traumatic Rupture of Valsalva Sinus With Dissection Into the Interventricular Septum

    Get PDF

    A new score system for predicting response to cardiac resynchronization therapy

    Get PDF
    Background: The aim of this study was to establish a score system derived from clinical, echocardiographic and electrocardiographic indexes and evaluate its clinical value for cardiac resynchronization therapy (CRT) patient selection. Methods: Ninety-three patients receiving CRT were enrolled. A patient selection score system was generated by the clinical, echocardiographic and electrocardiographic parameters achieving a significant level by univariate and multivariate Cox regression model. The positive response to CRT was a left ventricular end systolic volume decrease of ≥ 15% and not reaching primary clinical endpoint (death or re-hospitalization for heart failure) at the end of follow-up. Results: Thirty-nine patients were CRT non-responders (41.94%) and 54 were responders (58.06%). A 4-point score system was generated based on tricuspid annular plane systolic ex­cursion (TAPSE), longitudinal strain (LS), and complete left bundle branch block (CLBBB) combined with a wide QRS duration (QRSd). The sensitivity and specificity for prediction of a positive response to CRT at a score > 2 were 0.823 and 0.850, respectively (AUC: 0.92295% CI 0.691–0.916, p< 0.001). Conclusions: A patient selection score system based on the integration of TAPSE, LS and CLBBB combined with a wide QRSd can help to predict positive response to CRT effectively and reliably

    Cyanosis in a Primum Atrial Septal Defect Without Pulmonary Hypertension

    Get PDF

    Application of Regent mechanical valve in patients with small aortic annulus: 3-year follow-up

    No full text
    Abstract Background Aortic valve replacement (AVR) with a small aortic annulus is always challenging for the cardiac surgeon. In this study, we sought to evaluate the midterm performance of implantation with a 17-mm or 19-mm St. Jude Medical Regent (SJM Regent) mechanical valve in retrospective consecutive cohort of patients with small aortic annulus (diameter ≤ 19 mm). Methods From January 2008 to April 2011, 40 patients (31 female, mean age = 47.2 ± 5.8 years) with small aortic annulus (≤19 mm in diameter) underwent aortic valve replacement with a 17-mm or 19-mm St. Jude Medical Regent (SJM Regent) mechanical valve. Preoperative mean body surface area, New York Heart Association class, and mean aortic annulus were 1.61 ± 0.26 m2, 3.2 ± 0.4, and 18 ± 1.4 mm respectively. Patients were divided into two groups, according to the implantation of 17 mm SJM Regent mechanical valve (group 1, n = 18) or 19 mm SJM Regent valve (group 2, n = 22). All patients underwent echocardiography examination preoperatively and at one year post-operation. Results There were no early deaths in either group. Follow-up time averaged 36 ± 17.6 months. The mean postoperative New York Heart Association class was 1.3 ± 0.6 (p 2/m2 to 69.8 ± 9.3%, 41.4 ± 8.3%, and 0.92 ± 0.10 cm2/m2 respectively (P 2, 46.1 ± 8.5 mmHg to 86.7 ± 18.2 g/m2 , 13.7 ± 5.2 mmHg respectively. In group 2, the LVEF, LVFS and EOAI increased from 45.9% ± 9.7%, 30.7% ± 8.0%, and 0.81 ± 0.09 cm2/m2 to 77.4% ± 9.7%, 44.5% ± 9.6%, and 1.27 ± 0.11 cm2/m2 respectively, while the LVMI, and the aortic transvalvular pressure gradient decreased from 118.3 ± 27.6 g/m2, 44.0 ± 6.7 mmHg to 80.1 ± 19.7 g/m2, 10.8 ± 4.1 mmHg as well. The prevalence of PPM was documented in 2 patients in Group 1. Conclusions Patients with small aortic annulus and body surface area, experienced satisfactory clinical improvement after aortic valve replacement with modern SJM Regent bileaflet prostheses.</p

    Anomalous left coronary artery with single ostium (Shared with Right Coronary Artery) detected by echocardiography: Two case reports

    No full text
    Anomalous aortic origin of a coronary artery (AAOCA) from the inappropriate sinus of Valsalva has received increasing attention due to its association with malignant cardiac events in otherwise healthy and asymptomatic individuals. Despite this, we still face tremendous challenges in detecting the anomalies in a timely fashion to prevent sudden cardiac death. Here, we present two cases of anomalous left coronary artery with single ostium (shared with right coronary artery); in patients with normal cardiac function. The diagnosis of AAOCA in both cases was first suspected on transthoracic echocardiography and was later established using either coronary computed tomography angiography or invasive coronary angiography. Although angiography is the gold standard for diagnosing AAOCA, echocardiography is a more frequently used imaging modality in the workup of cardiac patients

    Real-Time Monitoring and Step-by-Step Guidance for Transapical Mitral Valve Edge-to-Edge Repair Using Transesophageal Echocardiography

    No full text
    MitraClip edge-to-edge (E2E) repair system is the only transcatheter device recommended in the current guidelines for treating mitral regurgitation (MR). The percutaneous femoral venous transseptal access of MitraClip requires a complex steerable delivery system and may thus be technically complex to optimally position and deploy the clip onto the mitral valve. A transapical approach for E2E repair has been devised to treat MR for the ease of operation (ValveClamp system, Hanyu Medical Technology, Shanghai). The first-in-human study of ValveClamp has demonstrated its early feasibility and effectiveness for the treatment of patients with degenerative MR. Transesophageal echocardiography (TEE) is the only imaging modality required for intraoperative guidance of ValveClamp implantation. Successful implantation depends on accurate localization and orientation of the clamp and efficient intraoperative communication between the echocardiographer and the intervention team. Thus, the focus of this review is on elaborating how two-dimensional (2D) and three-dimensional (3D) TEE are used in clinical practice to guide ValveClamp implantation and it may facilitate the understanding of simplicity and safety of this novel procedure. We also describe the implementation of several novel advancements in 3D TEE imaging, which improve the confidence of image interpretation for intraoperative guidance and expedite implantation times

    The myocardial ischemia evaluated by real-time contrast echocardiography may predict the response to cardiac resynchronization therapy: a large animal study.

    No full text
    Evidence-based criteria for applying cardiac resynchronization therapy (CRT) in patients with ischemic cardiomyopathy are still scarce. The aim of the present study was to evaluate the predictive value of real-time myocardial contrast echocardiography (RT-MCE) in a preclinical canine model of ischemic cardiomyopathy who received CRT. Ischemic cardiomyopathy was produced by ligating the first diagonal branch in 20 beagles. Dogs were subsequently divided into two groups that were either treated with bi-ventricular pacing (CRT group) or left untreated (control group). RT-MCE was performed at baseline, before CRT, and 4 weeks after CRT. Two-dimensional speckle tracking imaging was used to evaluate the standard deviation of circumferential (Cir12SD), radial (R12SD), and longitudinal (L12SD) strains of left ventricular segments at basal as well as middle levels. Four weeks later, the Cir12SD, R12SD, and myocardial blood flow (MBF) of the treated group were significantly improved compared to their non-CRT counterparts. Furthermore, MBF values measured before CRT were significantly higher in responders than in non-responders to bi-ventricular pacing. Meanwhile, no significant differences were observed between the responder and non-responder groups in terms of Cir12SD, R12SD, and L12SD. A high degree of correlation was found between MBF values before CRT and LVEF after CRT. When MBF value>24.9 dB/s was defined as a cut-off point before CRT, the sensitivity and specificity of RT-MCE in predicting the response to CRT were 83.3% and 100%, respectively. Besides, MBF values increased significantly in the CRT group compared with the control group after 4 weeks of pacing (49.8±15.5 dB/s vs. 28.5±4.6 dB/s, p<0.05). Therefore, we considered that myocardial perfusion may be superior to standard metrics of LV synchrony in selecting appropriate candidates for CRT. In addition, CRT can improve myocardial perfusion in addition to cardiac synchrony, especially in the setting of ischemic cardiomyopathy

    Early detection of anthracycline-induced cardiotoxicity using two-dimensional speckle tracking echocardiography

    Get PDF
    Background: To examine the subclinical myocardial injury shortly after epirubicin exposure in asymptomatic patients with large B-cell non-Hodgkin lymphoma using 2-dimensional (2D)speckle tracking echocardiography.Methods: Sixty-seven patients aged 52.58 ± 13.86 years with large B-cell non-Hodgkin lymphoma treated with epirubicin were studied. Echocardiography was performed at baseline and 1 day after completion of the therapy. Global and regional longitudinal (LS), circumferential (CS) and radial strain (RS), standard deviation of time to peak LS (TLS-SD), CS (TCS-SD), RS(TRS-SD) were calculated using 2D speckle tracking echocardiography.Results: Despite normal left ventricular ejection fraction, global LS (–18.30 ± 1.87% vs.–16.18 ± 1.92%; p &lt; 0.01), CS (–20.37 ± 2.89% vs. –18.25 ± 2.40%, p &lt; 0.01) and RS (39.95 ± 5.79% vs. 36.15 ± 5.79%, p &lt; 0.01), were remarkably reduced compared to baseline values. However, TLS-SD, TCS-SD and TRS-SD showed no significant difference after epirubicin exposure. Hypertension was an independent predictor of reduction of global LS, CS and RS.Conclusions: Subtle abnormalities in myocardial systolic function were present in asymptomatic patients shortly after anthracycline exposure, which could be detected by 2D speckle tracking echocardiography
    corecore