6 research outputs found
A systematic review on diagnostic test accuracy of magnetic resonance neurography versus clinical neurosensory assessment for post-traumatic trigeminal neuropathy in patients reporting neurosensory disturbance
Objectives: To perform a systematic review of published studies on diagnostic accuracy of magnetic resonance neurography (MRN) vs clinical neurosensory testing (NST) for post-traumatic trigeminal neuropathy (PTTN) in patients reporting neurosensory disturbances (NSD).
Methods: Human studies except case reports, reviews, systematic reviews and meta-analyses were included. PubMed, Embase, Web of Science and Cochrane Library were consulted. Risk of bias assessment was conducted using the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Predetermined data extraction parameters were noted and summarized.
Results: 8 studies met eligibility criteria of which 7 were retrospective, representing 444 subjects. Most studies were at high risk of bias with low applicability concerns. Populations and objectives were divergent with a large variation in timing (3 days-17 years post injury) and parameters (multiple coil designs, fat suppression techniques, additional contrast agent) of MRI acquisition. T-2 weighted 3 T imaging with short echo times (2.2-100 ms) and fat suppression was applied in seven studies, techniques varied. Determination of sensitivity and specificity could not be performed due to the methodological variation between studies and lacking comparative data between index and reference tests. Based on limited data, PTTN correlated reasonably well between clinical assessment, intraoperative findings and MRN abnormalities (k = 0.57). Increased signal intensity correlated with persistency of neurosensory disturbances in one study. Intra- (ICC 0.914-0.927) and interobserver (k = 0.70-0.891) MRN variability was considered good to excellent. One retrospective study showed substantial impact of MRN on clinical decision making in one-third of patients.
Conclusion: Currently, there is insufficient scientific knowledge to support or refute the use of MRN. Based on limited data, MRN seems promising and reliable in detection and grading of PTTN. Methodological issues underline the importance for prospective blinded studies with standardization of signal intensity calculation and rigorous reporting of MRI acquisition parameters
The Accuracy of Three-Dimensional Soft Tissue Simulation in Orthognathic Surgery—A Systematic Review
Three-dimensional soft tissue simulation has become a popular tool in the process of virtual orthognathic surgery planning and patient–surgeon communication. To apply 3D soft tissue simulation software in routine clinical practice, both qualitative and quantitative validation of its accuracy are required. The objective of this study was to systematically review the literature on the accuracy of 3D soft tissue simulation in orthognathic surgery. The Web of Science, PubMed, Cochrane, and Embase databases were consulted for the literature search. The systematic review (SR) was conducted according to the PRISMA statement, and 40 articles fulfilled the inclusion and exclusion criteria. The Quadas-2 tool was used for the risk of bias assessment for selected studies. A mean error varying from 0.27 mm to 2.9 mm for 3D soft tissue simulations for the whole face was reported. In the studies evaluating 3D soft tissue simulation accuracy after a Le Fort I osteotomy only, the upper lip and paranasal regions were reported to have the largest error, while after an isolated bilateral sagittal split osteotomy, the largest error was reported for the lower lip and chin regions. In the studies evaluating simulation after bimaxillary osteotomy with or without genioplasty, the highest inaccuracy was reported at the level of the lips, predominantly the lower lip, chin, and, sometimes, the paranasal regions. Due to the variability in the study designs and analysis methods, a direct comparison was not possible. Therefore, based on the results of this SR, guidelines to systematize the workflow for evaluating the accuracy of 3D soft tissue simulations in orthognathic surgery in future studies are proposed
Magnetic resonance neurography of the head and neck:State of the art, anatomy, pathology and future perspectives
Magnetic resonance neurography allows for the selective visualization of peripheral nerves and is increasingly being investigated. Whereas in the past, the imaging of the extracranial cranial and occipital nerve branches was inadequate, more and more techniques are now available that do allow nerve imaging. This basic review provides an overview of the literature with current state of the art, anatomical landmarks and future perspectives. Furthermore, we illustrate the possibilities of the three-dimensional CRAnial Nerve Imaging (3D CRANI) MR-sequence by means of a few case studies
A systematic review on diagnostic test accuracy of magnetic resonance neurography versus clinical neurosensory assessment for post-traumatic trigeminal neuropathy in patients reporting neurosensory disturbance.
OBJECTIVES: To perform a systematic review of published studies on diagnostic accuracy of magnetic resonance neurography (MRN) vs clinical neurosensory testing (NST) for post-traumatic trigeminal neuropathy (PTTN) in patients reporting neurosensory disturbances (NSD). METHODS: Human studies except case reports, reviews, systematic reviews and meta-analyses were included. PubMed, Embase, Web of Science and Cochrane Library were consulted. Risk of bias assessment was conducted using the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Predetermined data extraction parameters were noted and summarized. RESULTS: 8 studies met eligibility criteria of which 7 were retrospective, representing 444 subjects. Most studies were at high risk of bias with low applicability concerns. Populations and objectives were divergent with a large variation in timing (3 days-17 years post injury) and parameters (multiple coil designs, fat suppression techniques, additional contrast agent) of MRI acquisition. T2 weighted 3 T imaging with short echo times (2.2-100 ms) and fat suppression was applied in seven studies, techniques varied. Determination of sensitivity and specificity could not be performed due to the methodological variation between studies and lacking comparative data between index and reference tests. Based on limited data, PTTN correlated reasonably well between clinical assessment, intraoperative findings and MRN abnormalities (k = 0.57). Increased signal intensity correlated with persistency of neurosensory disturbances in one study. Intra- (ICC 0.914-0.927) and interobserver (k = 0.70-0.891) MRN variability was considered good to excellent. One retrospective study showed substantial impact of MRN on clinical decision making in one-third of patients. CONCLUSION: Currently, there is insufficient scientific knowledge to support or refute the use of MRN. Based on limited data, MRN seems promising and reliable in detection and grading of PTTN. Methodological issues underline the importance for prospective blinded studies with standardization of signal intensity calculation and rigorous reporting of MRI acquisition parameters.status: Published onlin
Orofacial quantitative sensory testing: Current evidence and future perspectives
BACKGROUND AND OBJECTIVE: Orofacial quantitative sensory testing (QST) is an increasingly valuable psychophysical tool for evaluating neurosensory disorders of the orofacial region. Here, we aimed to evaluate the current evidence regarding this testing method and to discuss its future clinical potential. DATA TREATMENT: We conducted a literature search in Medline, Embase and Scopus for English-language articles published between 1990 and 2019. The utilized search terms included QST, quantitative, sensory testing and neurosensory, which were combined using the AND operator with the terms facial, orofacial, trigeminal, intraoral and oral. RESULTS: Our findings highlighted many methods for conducting QST-including method of levels, method of limits and mapping. Potential stimuli also vary, and can include mechanical or thermal stimulation, vibration or pinprick stimuli. Orofacial QST may be helpful in revealing disease pathways and can be used for patient stratification to validate the use of neurosensory profile-specific treatment options. QST is reportedly reliable in longitudinal studies and is thus a candidate for measuring changes over time. One disadvantage of QST is the substantial time required; however, further methodological refinements and the combination of partial aspects of the full QST battery with other tests and imaging methods should result in improvement. CONCLUSIONS: Overall, orofacial QST is a reliable testing method for diagnosing pathological neurosensory conditions and assessing normal neurosensory function. Despite the remaining challenges that hinder the use of QST for everyday clinical decisions and clinical trials, we expect that future improvements will allow its implementation in routine practice.status: publishe
European Quality Markers in Oral and Maxillofacial Surgery Specialty Training : Defining Standards
According to the European Union (EU) Directive 2005/36, the medical specialty of oral and maxillofacial surgery (OMFS) exists with two possible formats: dual degree OMFS called Dental, Oral and Maxillofacial Surgery (DOMFS) - basic medical and basic dental training and single medical degree Maxillofacial Surgery (MFS). Within the EU and across all of Europe, differences in the nature and quality of OMFS training coexist. By implementing the highest possible standards of training, patient care can be improved. To establish quality metrics for an ideal OMFS training programme, the European OMFS Trainee Forum of the Union Européenne des Médecins Spécialistes (UEMS) conducted a Delphi consensus protocol from November 2023 to January 2024. Facilitated by the OMFS Section of UEMS, 56 trainees from 32 countries participated. The process involved the definition of three quality levels using the red, amber, and green (RAG) rating system. Following the Delphi process, 46 domains were identified, including features within training programmes/rotations, teaching and education programmes, training placements, recording of training progression and activity, and external assessment of training programmes. The results were aligned with the UEMS OMFS European Training Requirement (ETR). With the introduction of a RAG rating, trainees and trainers can review their training programmes with the aim of improving them by moving domains from Red to Green. Raising the standard of training will benefit our patients. This initiative could mark a significant step towards the harmonisation of OMFS training, improving quality and ensuring consistent, high-level care throughout Europe.Peer reviewe