12 research outputs found

    On-line 3D motion estimation using low resolution MRI

    No full text
    Image processing such as deformable image registration finds its way into radiotherapy as a means to track non-rigid anatomy. With the advent of magnetic resonance imaging ( MRI ) guided radiotherapy, intrafraction anatomy snapshots become technically feasible.magnetic resonance ( MR ) imaging provides the needed tissue signal for high-fidelity image registration. However, acquisitions, especially in 3D, take a considerable amount of time. Pushing towards real-time adaptive radiotherapy, MR imaging needs to be accelerated without degrading the quality of information.In this paper, we investigate the impact of image resolution on the quality of motion estimations. Potentially, spatially undersampled images yield comparable motion estimations. At the same time, their acquisition times would reduce greatly due to the sparser sampling. In order to substantiate this hypothesis, an exemplary 4D dataset of the abdomen is downsampled gradually. Subsequently, spatiotemporal deformations are extracted consistently using the same motion estimation for each downsampled dataset. Errors between the original and the respectively downsampled version are then evaluated.Compared to ground-truth, results show high similarity of deformations estimated from downsampled image data. Using a dataset with (2.5mm) 3 voxel size, deformation fields could be recovered well up to a downsampling factor of 2, i.e. (5mm) 3 . In a therapy guidance scenario MRI , imaging speed would accordingly increase approximately fourfold, with acceptable loss of estimated motion quality

    Three-dimensional MRI-linac intra-fraction guidance using multiple orthogonal cine-MRI planes

    Get PDF
    The introduction of integrated MRI-radiation therapy systems will offer live intra-fraction imaging. We propose a feasible low-latency multi-plane MRI-linac guidance strategy. In this work we demonstrate how interleaved acquired, orthogonal cine-MRI planes can be used for low-latency tracking of the 3D trajectory of a soft-tissue target structure. The proposed strategy relies on acquiring a pre-treatment 3D breath-hold scan, extracting a 3D target template and performing template matching between this 3D template and pairs of orthogonal 2D cine-MRI planes intersecting the target motion path. For a 60 s free-breathing series of orthogonal cine-MRI planes, we demonstrate that the method was capable of accurately tracking the respiration related 3D motion of the left kidney. Quantitative evaluation of the method using a dataset designed for this purpose revealed a translational error of 1.15 mm for a translation of 39.9 mm. We have demonstrated how interleaved acquired, orthogonal cine-MRI planes can be used for online tracking of soft-tissue target volumes

    On-line MR imaging for dose validation of abdominal radiotherapy

    No full text
    For quality assurance and adaptive radiotherapy, validation of the actual delivered dose is crucial.Intrafractional anatomy changes cannot be captured satisfactorily during treatment with hitherto available imaging modalitites. Consequently, dosecalculations are based on the assumption of static anatomy throughout the treatment. However, intra- and interfraction anatomy is dynamic and changes can be significant. In particular, hypofractionated and escalated radiotherapy thus demand for reliable dose reconstruction based on periodic imaging.In this paper, we investigate the use of an MR -linac as a dose tracking modality for the validation of treatments in abdominal targets where both respiratory and long-term peristaltic and drift motion occurs.The on-line MR imaging capabilities of the modality provides the means to perform respiratory gating of both delivery and acquisition yielding a model-free respiratory motion management under free breathing conditions.In parallel to the treatment, the volumetric patient anatomy was captured and used to calculate the applied dose. Subsequently, the individual doses were warped back to the planing grid to obtain the actual dose accumulated over the entire treatment duration. Eventually, the planned dose was validated by comparison with the accumulated dose.Representatively for a site subject to breathing modulation, two kidney cases (25Gy target dose) demonstrated the working principle on volunteer data and simulated delivery. The proposed workflow successfully showed its ability to track local dosimetric changes. Integration of the on-line anatomy information could reveal local dose variations −2.3 to 1.5Gy in the target volume of a volunteer dataset. In the adjacent organs at risk, high local dose errors ranging from −2.5 to 1.9Gy could be traced back

    Thermal noise variance of a receive radiofrequency coil as a respiratory motion sensor

    No full text
    \u3cp\u3ePURPOSE: Development of a passive respiratory motion sensor based on the noise variance of the receive coil array.\u3c/p\u3e\u3cp\u3eMETHODS: Respiratory motion alters the body resistance. The noise variance of an RF coil depends on the body resistance and, thus, is also modulated by respiration. For the noise variance monitoring, the noise samples were acquired without and with MR signal excitation on clinical 1.5/3 T MR scanners. The performance of the noise sensor was compared with the respiratory bellow and with the diaphragm displacement visible on MR images. Several breathing patterns were tested.\u3c/p\u3e\u3cp\u3eRESULTS: The noise variance demonstrated a periodic, temporal modulation that was synchronized with the respiratory bellow signal. The modulation depth of the noise variance resulting from the respiration varied between the channels of the array and depended on the channel's location with respect to the body. The noise sensor combined with MR acquisition was able to detect the respiratory motion for every k-space read-out line.\u3c/p\u3e\u3cp\u3eCONCLUSION: Within clinical MR systems, the respiratory motion can be detected by the noise in receive array. The noise sensor does not require careful positioning unlike the bellow, any additional hardware, and/or MR acquisition. Magn Reson Med 77:221-228, 2017. © 2016 Wiley Periodicals, Inc.\u3c/p\u3

    Moderately degenerated lumbar motion segments: are they truly unstable?

    Get PDF
    The two main load bearing tissues of the intervertebral disc are the nucleus pulposus and the annulus fibrosus. Both tissues are composed of the same basic components, but differ in their organization and relative amounts. With degeneration, the clear distinction between the two tissues disappears. The changes in biochemical content lead to changes in mechanical behaviour of the intervertebral disc. The aim of the current study was to investigate if well-documented moderate degeneration at the biochemical and fibre structure level leads to instability of the lumbar spine. By taking into account biochemical and ultrastructural changes to the extracellular matrix of degenerating discs, a set of constitutive material parameters were determined that described the individual tissue behaviour. These tissue biomechanical models were then used to simulate dynamic behaviour of the degenerated spinal motion segment, which showed instability in axial rotation, while a stabilizing effect in the other two principle bending directions. When a shear load was applied to the degenerated spinal motion segment, no sign of instability was found. This study found that reported changes to the nucleus pulposus and annulus fibrosus matrix during moderate degeneration lead to a more stable spinal motion segment and that such biomechanical considerations should be incorporated into the general pathophysiological understanding of disc degeneration and how its progress could affect low back pain and its treatments thereof