50 research outputs found

    Preoperative Assessment of Anomalous Right Coronary Artery Arising from the Main Pulmonary Artery

    Get PDF
    Anomalous origin of the right coronary artery from the pulmonary artery is a rare condition. Two cases are presented in this paper. One case was treated by ligation and coronary artery bypass. The other was treated by direct reimplantation of the anomalous coronary artery into the aorta

    Operative management after transcatheter aortic valve replacement

    Get PDF
    With broadening applications of transcatheter aortic valve replacement (TAVR) and increasing use in intermediate- and low-risk patients, the incidence of surgical re-interventions after TAVR is growing. Transcatheter heart valves suffer from similar long-term complications as surgical heart valve prostheses that require surgical re-intervention, including endocarditis and structural valve deterioration. Catastrophic periprocedural complications — such as annular or aortic rupture requiring urgent surgical intervention — may also occur during TAVR procedures. This review summarizes the current knowledge on indications, methods, and outcomes of cardiac operations after TAVR, with a focus on how to improve results in a rapidly growing patient population

    Association of Bovine Arch Anatomy With Incident Stroke After Transcatheter Aortic Valve Replacement

    Get PDF
    BACKGROUND: Acute ischemic stroke complicates 2 % to 3 % of transcatheter aortic valve replacements (TAVRs). This study aimed to identify the aortic anatomic correlates in patients after TAVR stroke. METHODS AND RESULTS: This is a single-center, retrospective study of patients who underwent TAVR at the Mayo Clinic between 2012 and 2022. The aortic arch morphology was determined via a manual review of the pre-TAVR computed tomography images. An a priori approach was used to select the covariates for the following: (1) the logistic regression model assessing the association between a bovine arch and periprocedural stroke (defined as stroke within 7 days after TAVR) and (2) the Cox proportional hazards regression model assessing the association between a bovine arch and long-term stroke after TAVR. A total of 2775 patients were included (59.6 % men, 97.8 % White race, mean ± SD age, 79.3 ± 8.4 years), of whom 495 (17.8 %) had a bovine arch morphology. Fifty-seven patients (1.7 %) experienced a periprocedural stroke. The incidence of acute stroke was significantly higher among patients with a bovine arch compared with those with a nonbovine arch (3.6% versus 1.7%; =0.01). After adjustment, a bovine arch was independently associated with increased periprocedural strokes (adjusted odds ratio, 2.16 [95 % CI, 1.22-3.83]). At a median follow-up of 2.7 years, the overall incidence of post-TAVR stroke was 6.0 % and was significantly higher in patients with a bovine arch even after adjusting for potential confounders (10.5 % versus 5.0 % adjusted hazard ratio, 2.11 [95 % CI, 1.51-2.93], \u3c 0.001). CONCLUSIONS: A bovine arch anatomy is associated with a significantly higher risk of periprocedural and long-term stroke after TAVR

    Predicting postoperative systolic dysfunction in mitral regurgitation: CT vs. echocardiography

    Get PDF
    IntroductionVolume overload from mitral regurgitation can result in left ventricular systolic dysfunction. To prevent this, it is essential to operate before irreversible dysfunction occurs, but the optimal timing of intervention remains unclear. Current echocardiographic guidelines are based on 2D linear measurement thresholds only. We compared volumetric CT-based and 2D echocardiographic indices of LV size and function as predictors of post-operative systolic dysfunction following mitral repair.MethodsWe retrospectively identified patients with primary mitral valve regurgitation who underwent repair between 2005 and 2021. Several indices of LV size and function measured on preoperative cardiac CT were compared with 2D echocardiography in predicting post-operative LV systolic dysfunction (LVEFecho <50%). Area under the curve (AUC) was the primary metric of predictive performance.ResultsA total of 243 patients were included (mean age 57 ± 12 years; 65 females). The most effective CT-based predictors of post-operative LV systolic dysfunction were ejection fraction [LVEFCT; AUC 0.84 (95% CI: 0.77–0.92)] and LV end systolic volume indexed to body surface area [LVESViCT; AUC 0.88 (0.82–0.95)]. The best echocardiographic predictors were LVEFecho [AUC 0.70 (0.58–0.82)] and LVESDecho [AUC 0.79 (0.70–0.89)]. LVEFCT was a significantly better predictor of post-operative LV systolic dysfunction than LVEFecho (p = 0.02) and LVESViCT was a significantly better predictor than LVESDecho (p = 0.03). Ejection fraction measured by CT demonstrated significantly greater reproducibility than echocardiography.DiscussionCT-based volumetric measurements may be superior to established 2D echocardiographic parameters for predicting LV systolic dysfunction following mitral valve repair. Validation with prospective study is warranted

    Unicuspid Aortic Stenosis in a Patient with Turner Syndrome: A Case Report

    No full text
    Congenital aortic valve anomalies are the cause of premature aortic stenosis in pediatric and younger adult populations. Despite being very rare, unicuspid aortic valves account for approximately 5% of isolated aortic valve replacements. Patients with aortic stenosis, present with the same symptomatology independent of leaflet morphology. However, the presence of bicuspid and unicuspid aortic stenosis is associated with a higher incidence of aortopathy, especially in Turner syndrome patients. Turner syndrome, an X monosomy, is associated with aortic valve anomalies, aortopathy, and hypertension. These risk factors lead to a higher incidence of aortic dissection in this population. Patients with Turner syndrome and aortic stenosis that present for aortic valve replacement should therefore undergo extensive aortic imaging prior to surgery.Transthoracic echocardiography is the diagnostic tool of choice for valvular pathology, yet it can misdiagnose unicuspid aortic valves as bicuspid valves due to certain similarities on imaging. Transesophageal echocardiography is a better tool for distinguishing between the two valvular abnormalities, although diagnostic errors can still occur. We present a case of a 50-year-old female with history of Turner syndrome and bicuspid aortic stenosis presenting for aortic valve replacement and ascending aorta replacement. Intraoperative transesophageal echocardiography revealed a stenotic unicommissural unicuspid aortic valve with an eccentric orifice, which was missed on preoperative imaging. This case highlights the importance of intraoperative transesophageal echocardiography in confirming preoperative findings, diagnosing further cardiac pathology, and ensuring adequate surgical repair
    corecore