7 research outputs found

    In vivo import of plastocyanin and a fusion protein into developmentally different plastids of transgenic plants

    Get PDF
    Transgenic tomato plants that constitutively express a foreign plastocyanin gene were used to study protein transport in different tissues. Normally expression of endogenous plastocyanin genes in plants is restricted to photosynthetic tissues only, whereas this foreign plastocyanin protein is found to be present in all tissues examined. The protein is transported into the local plastids in these tissues and it is processed to the mature size. We conclude that plastids of developmentally different tissues are capable of importing precursor proteins that are normally not found in these tissues. Most likely such plastids, though functionally and morphologically differentiated, have similar or identical protein import mechanisms when compared to the chloroplasts in green tissue

    Instrument markers for magnetic particle and magnetic resonance imaging

    No full text
    For MPI, with its huge potential for cardiovascular applications, there is the need to develop dedicated interventional instruments. Especially, for MPI-MRI hybrid imaging approaches the instruments must be both, safe and visible in each modality. The purpose of this study was to manufacture bimodal instrument markers for MPI and MRI. To guarantee sufficient imaging performance in both modalities, the markers are based on two different particle types

    Bimodal Interventional Instrument Markers for Magnetic Particle Imaging and Magnetic Resonance Imaging—A Proof-of-Concept Study

    No full text
    The purpose of this work was to develop instrument markers that are visible in both magnetic particle imaging (MPI) and magnetic resonance imaging (MRI). The instrument markers were based on two different magnetic nanoparticle types (synthesized in-house KLB and commercial Bayoxide E8706). Coatings containing one of both particle types were fabricated and measured with a magnetic particle spectrometer (MPS) to estimate their MPI performance. Coatings based on both particle types were then applied on a segment of a nonmetallic guidewire. Imaging experiments were conducted using a commercial, preclinical MPI scanner and a preclinical 1 tesla MRI system. MPI image reconstruction was performed based on system matrices measured with dried KLB and Bayoxide E8706 coatings. The bimodal markers were clearly visible in both methods. They caused circular signal voids in MRI and areas of high signal intensity in MPI. Both the signal voids as well as the areas of high signal intensity were larger than the real marker size. Images that were reconstructed with a Bayoxide E8706 system matrix did not show sufficient MPI signal. Instrument markers with bimodal visibility are essential for the perspective of monitoring cardiovascular interventions with MPI/MRI hybrid systems
    corecore