Comparison of SNR efficiencies and strain for cine DENSE using conventional EPI, flyback EPI and spiral k-space trajectories
The original implementation of 2D cine DENSE (displacement encoding with stimulated echoes) employed a conventional EPI k-space trajectory for rapid data sampling. Follow-up studies used flyback EPI to reduce image artifacts. More recently a spiral k-space trajectory was utilized for improved SNR
Breath-held 3D coronary vessel wall imaging with dual-density spiral acquisition and parallel imaging
Rapid whole-brain quantitative MT imaging
PURPOSE
To provide a robust whole-brain quantitative magnetization transfer (MT) imaging method that is not limited by long acquisition times.
METHODS
Two variants of a spiral 2D interleaved multi-slice spoiled gradient echo (SPGR) sequence are used for rapid quantitative MT imaging of the brain at 3 T. A dual flip angle, steady-state prepared, double-contrast method is used for combined B and-T mapping in combination with a single-contrast MT-prepared acquisition over a range of different saturation flip angles (50 deg to 850 deg) and offset frequencies (1 kHz and 10 kHz). Five sets (containing minimum 6 to maximum 18 scans) with different MT-weightings were acquired. In addition, main magnetic field inhomogeneities (ΔB) were measured from two Cartesian low-resolution 2D SPGR scans with different echo times. Quantitative MT model parameters were derived from all sets using a two-pool continuous-wave model analysis, yielding the pool-size ratio, F, their exchange rate, k, and their transverse relaxation time, T.
RESULTS
Whole-brain quantitative MT imaging was feasible for all sets with total acquisition times ranging from 7:15 min down to 3:15 min. For accurate modeling, B-correction was essential for all investigated sets, whereas ΔB-correction showed limited bias for the observed maximum off-resonances at 3 T.
CONCLUSION
The combination of rapid B-T mapping and MT-weighted imaging using a 2D multi-slice spiral SPGR research sequence offers excellent prospects for rapid whole-brain quantitative MT imaging in the clinical setting
Interferometric Constraints on Quantum Geometrical Shear Noise Correlations
Final measurements and analysis are reported from the first-generation
Holometer, the first instrument capable of measuring correlated variations in
space-time position at strain noise power spectral densities smaller than a
Planck time. The apparatus consists of two co-located, but independent and
isolated, 40 m power-recycled Michelson interferometers, whose outputs are
cross-correlated to 25 MHz. The data are sensitive to correlations of
differential position across the apparatus over a broad band of frequencies up
to and exceeding the inverse light crossing time, 7.6 MHz. By measuring with
Planck precision the correlation of position variations at spacelike
separations, the Holometer searches for faint, irreducible correlated position
noise backgrounds predicted by some models of quantum space-time geometry. The
first-generation optical layout is sensitive to quantum geometrical noise
correlations with shear symmetry---those that can be interpreted as a
fundamental noncommutativity of space-time position in orthogonal directions.
General experimental constraints are placed on parameters of a set of models of
spatial shear noise correlations, with a sensitivity that exceeds the
Planck-scale holographic information bound on position states by a large
factor. This result significantly extends the upper limits placed on models of
directional noncommutativity by currently operating gravitational wave
observatories.Comment: Matches the journal accepted versio
Rapid evaluation of right ventricular volume and mass without breath-holding using real-time interactive cardiac magnetic resonance imaging system
Quantitative first-pass MRI measures increased myocardial perfusion after vasodilation in mice
Comprehensive Cardiovascular magnetic resonance of myocardial mechanics in mice using three-dimensional cine DENSE
<p>Abstract</p> <p>Background</p> <p>Quantitative noninvasive imaging of myocardial mechanics in mice enables studies of the roles of individual genes in cardiac function. We sought to develop comprehensive three-dimensional methods for imaging myocardial mechanics in mice.</p> <p>Methods</p> <p>A 3D cine DENSE pulse sequence was implemented on a 7T small-bore scanner. The sequence used three-point phase cycling for artifact suppression and a stack-of-spirals <it>k</it>-space trajectory for efficient data acquisition. A semi-automatic 2D method was adapted for 3D image segmentation, and automated 3D methods to calculate strain, twist, and torsion were employed. A scan protocol that covered the majority of the left ventricle in a scan time of less than 25 minutes was developed, and seven healthy C57Bl/6 mice were studied.</p> <p>Results</p> <p>Using these methods, multiphase normal and shear strains were measured, as were myocardial twist and torsion. Peak end-systolic values for the normal strains at the mid-ventricular level were 0.29 ± 0.17, -0.13 ± 0.03, and -0.18 ± 0.14 for <it>E<sub>rr</sub></it>, <it>E<sub>cc</sub></it>, and <it>E<sub>ll</sub></it>, respectively. Peak end-systolic values for the shear strains were 0.00 ± 0.08, 0.04 ± 0.12, and 0.03 ± 0.07 for <it>E<sub>rc</sub></it>, <it>E<sub>rl</sub></it>, and <it>E<sub>cl</sub></it>, respectively. The peak end-systolic normalized torsion was 5.6 ± 0.9°.</p> <p>Conclusions</p> <p>Using a 3D cine DENSE sequence tailored for cardiac imaging in mice at 7 T, a comprehensive assessment of 3D myocardial mechanics can be achieved with a scan time of less than 25 minutes and an image analysis time of approximately 1 hour.</p
Arterial spin labeling MRI to measure peak-exercise calf muscle perfusion reproducibly discriminates peripheral arterial disease from normal
- …