64 research outputs found
App-based Self-administrable Clinical Tests of Physical Function: Development and Usability Study
BACKGROUND: Objective measures of physical function in older adults are widely used to predict health outcomes such as disability, institutionalization, and mortality. App-based clinical tests allow users to assess their own physical function and have objective tracking of changes over time by use of their smartphones. Such tests can potentially guide interventions remotely and provide more detailed prognostic information about the participant's physical performance for the users, therapists, and other health care personnel. We developed 3 smartphone apps with instrumented versions of the Timed Up and Go (Self-TUG), tandem stance (Self-Tandem), and Five Times Sit-to-Stand (Self-STS) tests. OBJECTIVE: This study aimed to test the usability of 3 smartphone app-based self-tests of physical function using an iterative design. METHODS: The apps were tested in 3 iterations: the first (n=189) and second (n=134) in a lab setting and the third (n=20) in a separate home-based study. Participants were healthy adults between 60 and 80 years of age. Assessors observed while participants self-administered the tests without any guidance. Errors were recorded, and usability problems were defined. Problems were addressed in each subsequent iteration. Perceived usability in the home-based setting was assessed by use of the System Usability Scale, the User Experience Questionnaire, and semi-structured interviews. RESULTS: In the first iteration, 7 usability problems were identified; 42 (42/189, 22.0%) and 127 (127/189, 67.2%) participants were able to correctly perform the Self-TUG and Self-Tandem, respectively. In the second iteration, errors caused by the problems identified in the first iteration were drastically reduced, and 108 (108/134, 83.1%) and 106 (106/134, 79.1%) of the participants correctly performed the Self-TUG and Self-Tandem, respectively. The first version of the Self-STS was also tested in this iteration, and 40 (40/134, 30.1%) of the participants performed it correctly. For the third usability test, the 7 usability problems initially identified were further improved. Testing the apps in a home setting gave rise to some new usability problems, and for Self-TUG and Self-STS, the rates of correctly performed trials were slightly reduced from the second version, while for Self-Tandem, the rate increased. The mean System Usability Scale score was 77.63 points (SD 16.1 points), and 80-95% of the participants reported the highest or second highest positive rating on all items in the User Experience Questionnaire. CONCLUSIONS: The study results suggest that the apps have the potential to be used to self-test physical function in seniors in a nonsupervised home-based setting. The participants reported a high degree of ease of use. Evaluating the usability in a home setting allowed us to identify new usability problems that could affect the validity of the tests. These usability problems are not easily found in the lab setting, indicating that, if possible, app usability should be evaluated in both settings. Before being made available to end users, the apps require further improvements and validation
Accidental neck and chest penetration by a metal sliver derived from an axe for wood chopping: A case report
Background: Penetrating neck and chest trauma is a very common entity in emergency medicine that usually requires surgical treatment. Our case report illustrates the case of a 27-year-old Arabian man with hemopneumothorax associated with pneumomediastinum due to an unusual occupational injury. Case presentation: A metal sliver, coming from an axe using for wood chopping, penetrated the neck of a 27-year-old Arabian man in the left supraclavicular region mimicking a gun bullet; the entrance hole was at the left pleural dome where the sliver had just penetrated the apex of the lung passing through the upper lobe of his left lung creating an exit wound in the dorsal segment of the same lobe arriving in the posterior thoracic wall. Biportal video-assisted thoracic surgery was performed to remove blood clots and the unusual foreign body. Conclusion: In the literature, there are several case series about this topic, with some of them reporting unusual foreign bodies that lead to penetrating trauma. However, to the best of our knowledge, no cases like the one we have reported are described in the current literature
Cardiac resynchronization therapy: a comparison among left ventricular bipolar, quadripolar and active fixation leads
We evaluated the performance of 3 different left ventricular leads (LV) for resynchronization therapy: bipolar (BL), quadripolar (QL) and active fixation leads (AFL). We enrolled 290 consecutive CRTD candidates implanted with BL (n = 136) or QL (n = 97) or AFL (n = 57). Over a minimum 10 months follow-up, we assessed: (a) composite technical endpoint (TE) (phrenic nerve stimulation at 8 [email protected] ms, safety margin between myocardial and phrenic threshold <2V, LV dislodgement and failure to achieve the target pacing site), (b) composite clinical endpoint (CE) (death, hospitalization for heart failure, heart transplantation, lead extraction for infection), (c) reverse remodeling (RR) (reduction of end systolic volume >15%). Baseline characteristics of the 3 groups were similar. At follow-up the incidence of TE was 36.3%, 14.3% and 19.9% in BL, AFL and QL, respectively (p < 0.01). Moreover, the incidence of RR was 56%, 64% and 68% in BL, AFL and QL respectively (p = 0.02). There were no significant differences in CE (p = 0.380). On a multivariable analysis, “non-BL leads” was the single predictor of an improved clinical outcome. QL and AFL are superior to conventional BL by enhancing pacing of the target site: AFL through prevention of lead dislodgement while QL through improved management of phrenic nerve stimulation
Le acque minerali nella terapia termale: alcune considerazioni sulle caratteristiche microbiologiche
Portatori di Staphylococcus aureus enterotossico tra gli addetti a due mense aziendali del senese
From the period of October 1987 to January 1988, 9 samples were taken from 16 workers in company canteens situated in the Sienna area. The study of enterotoxin staphylococci strains was carried out of the pharynx, nose, skin of the face and the hands. The investigation required the use of the Staphylo-Zyme P.B.I. kit and RPLA Oxoid set. The most frequently found enterotoxins were A and D, either alone or together
- …